Literature DB >> 30416893

Passive Self Resonant Skin Patch Sensor to Monitor Cardiac Intraventricular Stroke Volume Using Electromagnetic Properties of Blood.

Fayez Alruwaili1, Kim Cluff1, Jacob Griffith1, Hussam Farhoud2.   

Abstract

This paper focuses on the development of a passive, lightweight skin patch sensor that can measure fluid volume changes in the heart in a non-invasive, point-of-care setting. The wearable sensor is an electromagnetic, self-resonant sensor configured into a specific pattern to formulate its three passive elements (resistance, capacitance, and inductance). In an animal model, a bladder was inserted into the left ventricle (LV) of a bovine heart, and fluid was injected using a syringe to simulate stoke volume (SV). In a human study, to assess the dynamic fluid volume changes of the heart in real time, the sensor frequency response was obtained from a participant in a 30° head-up tilt (HUT), 10° HUT, supine, and 10° head-down tilt positions over time. In the animal model, an 80-mL fluid volume change in the LV resulted in a downward frequency shift of 80.16 kHz. In the human study, there was a patterned frequency shift over time which correlated with ventricular volume changes in the heart during the cardiac cycle. Statistical analysis showed a linear correlation [Formula: see text] and 0.87 between the frequency shifts and fluid volume changes in the LV of the bovine heart and human participant, respectively. In addition, the patch sensor detected heart rate in a continuous manner with a 0.179% relative error compared to electrocardiography. These results provide promising data regarding the ability of the patch sensor to be a potential technology for SV monitoring in a non-invasive, continuous, and non-clinical setting.

Entities:  

Keywords:  RF resonant sensor; point-of-care; stroke volume; wearable sensor

Year:  2018        PMID: 30416893      PMCID: PMC6214405          DOI: 10.1109/JTEHM.2018.2870589

Source DB:  PubMed          Journal:  IEEE J Transl Eng Health Med        ISSN: 2168-2372            Impact factor:   3.316


  33 in total

Review 1.  Practice guidelines for pulmonary artery catheterization: an updated report by the American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization.

Authors: 
Journal:  Anesthesiology       Date:  2003-10       Impact factor: 7.892

2.  The utility of intra-operative three-dimensional transoesophageal echocardiography for dynamic measurement of stroke volume.

Authors:  K Suehiro; K Tanaka; T Yamada; T Matsuura; T Funao; T Mori; K Nishikawa
Journal:  Anaesthesia       Date:  2014-09-29       Impact factor: 6.955

3.  Stroke volume optimization: the new hemodynamic algorithm.

Authors:  Alexander Johnson; Thomas Ahrens
Journal:  Crit Care Nurse       Date:  2015-02       Impact factor: 1.708

4.  Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial.

Authors:  William T Abraham; Philip B Adamson; Robert C Bourge; Mark F Aaron; Maria Rosa Costanzo; Lynne W Stevenson; Warren Strickland; Suresh Neelagaru; Nirav Raval; Steven Krueger; Stanislav Weiner; David Shavelle; Bradley Jeffries; Jay S Yadav
Journal:  Lancet       Date:  2011-02-19       Impact factor: 79.321

Review 5.  Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision.

Authors:  Philip J Peyton; Simon W Chong
Journal:  Anesthesiology       Date:  2010-11       Impact factor: 7.892

6.  Comparison of left ventricular stroke volume assessment by two- and three-dimensional echocardiography in a swine model of acute myocardial infarction validated by thermodilution method.

Authors:  Yuichi J Shimada; Kiyotake Ishikawa; Yoshiaki Kawase; Dennis Ladage; Lisa Tilemann; Takahiro Shiota; Roger J Hajjar
Journal:  Echocardiography       Date:  2012-06-05       Impact factor: 1.724

7.  Stroke volume variation as a predictor of intravascular volume depression and possible hypotension during the early postoperative period after esophagectomy.

Authors:  Makoto Kobayashi; Masayoshi Koh; Takashi Irinoda; Eiji Meguro; Yoshiro Hayakawa; Akinori Takagane
Journal:  Ann Surg Oncol       Date:  2009-02-14       Impact factor: 5.344

Review 8.  Noninvasive continuous hemodynamic monitoring.

Authors:  Jasper Truijen; Johannes J van Lieshout; Wilbert A Wesselink; Berend E Westerhof
Journal:  J Clin Monit Comput       Date:  2012-06-14       Impact factor: 2.502

9.  Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit.

Authors:  Mehrdad Behnia; Sherry Powell; Linda Fallen; Houman Tamaddon; Masud Behnia
Journal:  Clin Med Insights Circ Respir Pulm Med       Date:  2013-09-08

10.  Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold.

Authors:  Tomoyuki Kido; Teruhito Kido; Masashi Nakamura; Kouki Watanabe; Michaela Schmidt; Christoph Forman; Teruhito Mochizuki
Journal:  J Cardiovasc Magn Reson       Date:  2016-08-24       Impact factor: 5.364

View more
  4 in total

Review 1.  Recent Advances in Wearable Optical Sensor Automation Powered by Battery versus Skin-like Battery-Free Devices for Personal Healthcare-A Review.

Authors:  Nikolay L Kazanskiy; Muhammad A Butt; Svetlana N Khonina
Journal:  Nanomaterials (Basel)       Date:  2022-01-21       Impact factor: 5.076

2.  Preliminary Analysis of Burn Degree Using Non-invasive Microwave Spiral Resonator Sensor for Clinical Applications.

Authors:  Pramod K B Rangaiah; Bappaditya Mandal; Erik Avetisyan; Arvind Selvan Chezhian; Bobins Augustine; Mauricio David Perez; Robin Augustine
Journal:  Front Med Technol       Date:  2022-04-05

Review 3.  Blood Pressure Sensors: Materials, Fabrication Methods, Performance Evaluations and Future Perspectives.

Authors:  Ahmed Al-Qatatsheh; Yosry Morsi; Ali Zavabeti; Ali Zolfagharian; Nisa Salim; Abbas Z Kouzani; Bobak Mosadegh; Saleh Gharaie
Journal:  Sensors (Basel)       Date:  2020-08-11       Impact factor: 3.576

4.  An amplitude-based characteristic parameter extraction algorithm for cerebral edema detection based on electromagnetic induction.

Authors:  Jingbo Chen; Gen Li; Huayou Liang; Shuanglin Zhao; Jian Sun; Mingxin Qin
Journal:  Biomed Eng Online       Date:  2021-08-03       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.