Toward continuous, noninvasive assessment of ventricular function and hemodynamics: wearable ballistocardiography.

Andrew D Wiens, Mozziyar Etemadi, Shuvo Roy, Liviu Klein, Omer T Inan.   

Abstract

Ballistocardiography, the measurement of the reaction forces of the body to cardiac ejection of blood, is one of the few techniques available for unobtrusively assessing the mechanical aspects of cardiovascular health outside clinical settings. Recently, multiple experimental studies involving healthy subjects and subjects with various cardiovascular diseases have demonstrated that the ballistocardiogram (BCG) signal can be used to trend cardiac output, contractility, and beat-by-beat ventricular function for arrhythmias. The majority of these studies has been performed with "fixed" BCG instrumentation-such as weighing scales or chairs-rather than wearable measurements. Enabling wearable, and thus continuous, recording of BCG signals would greatly expand the capabilities of the technique; however, BCG signals measured using wearable devices are morphologically dissimilar to measurements from "fixed" instruments, precluding the analysis and interpretation techniques from one domain to be applied to the other. In particular, the time intervals between the electrocardiogram (ECG) and BCG-namely, the R-J interval, a surrogate for measuring contractility changes-are significantly different for the accelerometer compared to a "fixed" BCG measurement. This paper addresses this need for quantitatively normalizing wearable BCG measurement to "fixed" measurements with a systematic experimental approach. With these methods, the same analysis and interpretation techniques developed over the past decade for "fixed" BCG measurement can be successfully translated to wearable measurements.

Entities:  

Mesh:

Year:  2014        PMID: 25265619      PMCID: PMC4532376          DOI: 10.1109/JBHI.2014.2359937

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  35 in total

1.  Nurse migration and international recruitment.

Authors:  J Buchan
Journal:  Nurs Inq       Date:  2001-12       Impact factor: 2.393

2.  Evaluating the lower-body electromyogram signal acquired from the feet as a noise reference for standing ballistocardiogram measurements.

Authors:  Omer T Inan; Gregory T A Kovacs; Laurent Giovangrandi
Journal:  IEEE Trans Inf Technol Biomed       Date:  2010-04-05

3.  Wearable seismocardiography.

Authors:  Paolo Castiglioni; Andrea Faini; Gianfranco Parati; Marco Di Rienzo
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2007

4.  CARDIAC OUTPUT IN MAN BY A DIRECT FICK METHOD: Effects of Posture, Venous Pressure Change, Atropine, And Adrenaline.

Authors:  J McMichael; E P Sharpey-Schafer
Journal:  Br Heart J       Date:  1944-01

5.  Robust ballistocardiogram acquisition for home monitoring.

Authors:  O T Inan; M Etemadi; R M Wiard; L Giovangrandi; G T A Kovacs
Journal:  Physiol Meas       Date:  2009-01-16       Impact factor: 2.833

6.  Preliminary results from standing ballistocardiography measurements in microgravity.

Authors:  Richard M Wiard; Omer T Inan; Laurent Giovangrandi; Charles Marsh Cuttino; Gregory T A Kovacs
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

7.  Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer.

Authors:  Keya Pandia; Omer T Inan; Gregory T A Kovacs; Laurent Giovangrandi
Journal:  Physiol Meas       Date:  2012-09-18       Impact factor: 2.833

8.  Unobtrusive online monitoring of sleep at home.

Authors:  Joonas Paalasmaa; Mikko Waris; Hannu Toivonen; Lasse Leppäkorpi; Markku Partinen
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

9.  Systolic time intervals in heart failure in man.

Authors:  A M Weissler; W S Harris; C D Schoenfeld
Journal:  Circulation       Date:  1968-02       Impact factor: 29.690

10.  Reductions in cardiac output, central blood volume, and stroke volume with thermal stress in normal men during exercise.

Authors:  L B Rowell; H J Marx; R A Bruce; R D Conn; F Kusumi
Journal:  J Clin Invest       Date:  1966-11       Impact factor: 14.808

View more
  13 in total

1.  Mitigation of Instrument-Dependent Variability in Ballistocardiogram Morphology: Case Study on Force Plate and Customized Weighing Scale.

Authors:  Yang Yao; Zahra Ghasemi; Md Mobashir Hasan Shandhi; Hazar Ashouri; Lisheng Xu; Ramakrishna Mukkamala; Omer T Inan; Jin-Oh Hahn
Journal:  IEEE J Biomed Health Inform       Date:  2019-02-25       Impact factor: 5.772

2.  A novel system identification technique for improved wearable hemodynamics assessment.

Authors:  Andrew D Wiens; Omer T Inan
Journal:  IEEE Trans Biomed Eng       Date:  2015-01-01       Impact factor: 4.538

3.  A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables.

Authors:  Mozziyar Etemadi; Omer T Inan; J Alex Heller; Sinan Hersek; Liviu Klein; Shuvo Roy
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2015-05-12       Impact factor: 3.833

4.  Wearable Sensing of Cardiac Timing Intervals from Cardiogenic Limb Vibration Signals.

Authors:  Andrew D Wiens; Ann Johnson; Omer T Inan
Journal:  IEEE Sens J       Date:  2016-12-22       Impact factor: 3.301

Review 5.  Wearable ballistocardiogram and seismocardiogram systems for health and performance.

Authors:  Mozziyar Etemadi; Omer T Inan
Journal:  J Appl Physiol (1985)       Date:  2017-08-10

6.  Quantifying and Reducing Posture-Dependent Distortion in Ballistocardiogram Measurements.

Authors:  Abdul Qadir Javaid; Andrew D Wiens; Nathaniel Forrest Fesmire; Mary Ann Weitnauer; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2015-06-04       Impact factor: 5.772

7.  Unified frame of reference improves inter-subject variability of seismocardiograms.

Authors:  Mikko Paukkunen; Petteri Parkkila; Raimo Kettunen; Raimo Sepponen
Journal:  Biomed Eng Online       Date:  2015-02-26       Impact factor: 2.819

8.  The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time.

Authors:  Peyman Yousefian; Sungtae Shin; Azin Mousavi; Chang-Sei Kim; Ramakrishna Mukkamala; Dae-Geun Jang; Byung-Hoon Ko; Jongwook Lee; Ui Kun Kwon; Youn Ho Kim; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2019-07-23       Impact factor: 4.379

9.  Physiological Association between Limb Ballistocardiogram and Arterial Blood Pressure Waveforms: A Mathematical Model-Based Analysis.

Authors:  Peyman Yousefian; Sungtae Shin; Azin Sadat Mousavi; Chang-Sei Kim; Barry Finegan; M Sean McMurtry; Ramakrishna Mukkamala; Dae-Geun Jang; Uikun Kwon; Youn Ho Kim; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2019-03-26       Impact factor: 4.379

10.  Realization and Technology Acceptance Test of a Wearable Cardiac Health Monitoring and Early Warning System with Multi-Channel MCGs and ECG.

Authors:  Wen-Yen Lin; Hong-Lin Ke; Wen-Cheng Chou; Po-Cheng Chang; Tsai-Hsuan Tsai; Ming-Yih Lee
Journal:  Sensors (Basel)       Date:  2018-10-19       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.