Wearable seismocardiography.

Paolo Castiglioni1, Andrea Faini, Gianfranco Parati, Marco Di Rienzo.   

Abstract

Seismocardiogram (SCG) is the recording of body vibrations induced by the heart beat. SCG contains information on cardiac mechanics, in particular heart sounds and cardiac output. In this paper we present a new wearable device for SCG recordings during long term monitorings, and the results of a validation test in 4 subjects. The system is based on the integration of the MagIC smart shirt (i.e., a textile-based wearable system for the assessment of ECG and respiratory movements), and an external triaxial MEMS accelerometer positioned on the left clavicle. SCG was estimated as the average of accelerations occurred in each heart beat. The SCG components due to the valve closure and to recoil forces following the heart contraction (ballistocardiogram) were extracted by high-pass (>18 Hz) and band-pass (0.6-20 Hz) filters respectively. Then the difference between the I and J waves of the ballistocardiogram (|I-J| index, possibly related to the cardiac output) was identified by an ad-hoc procedure and compared with the model flow indirect estimation of cardiac output. Validation on 4 volunteers showed that: 1) our wearable system provides statistically consistent estimates of both heart-sound related vibrations and recoil movements; 2) reliable estimates of the |I-J| index can be obtained by considering about 1 minute of SCG recording in stationary conditions; and 3) changes of the |I-J| index during exercise correlate well with changes of cardiac output estimated by the model flow.

Mesh:

Year:  2007        PMID: 18002865     DOI: 10.1109/IEMBS.2007.4353199

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  27 in total

1.  Simplified detection of myocardial ischemia by seismocardiography. Differentiation between causes of altered myocardial function.

Authors:  M Becker; A B Roehl; U Siekmann; A Koch; M de la Fuente; R Roissant; K Radermacher; N Marx; M Hein
Journal:  Herz       Date:  2013-06-23       Impact factor: 1.443

2.  Automatic Detection of Seismocardiogram Sensor Misplacement for Robust Pre-Ejection Period Estimation in Unsupervised Settings.

Authors:  Hazar Ashouri; Omer T Inan
Journal:  IEEE Sens J       Date:  2017-05-04       Impact factor: 3.301

3.  An Adaptive Seismocardiography (SCG)-ECG Multimodal Framework for Cardiac Gating Using Artificial Neural Networks.

Authors:  Jingting Yao; S Tridandapani; W F Auffermann; C A Wick; P T Bhatti
Journal:  IEEE J Transl Eng Health Med       Date:  2018-10-08       Impact factor: 3.316

4.  A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables.

Authors:  Mozziyar Etemadi; Omer T Inan; J Alex Heller; Sinan Hersek; Liviu Klein; Shuvo Roy
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2015-05-12       Impact factor: 3.833

5.  Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring.

Authors:  Chang-Sei Kim; Andrew M Carek; Ramakrishna Mukkamala; Omer T Inan; Jin-Oh Hahn
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-02       Impact factor: 4.538

6.  Evaluation of a novel integrated sensor system for synchronous measurement of cardiac vibrations and cardiac potentials.

Authors:  Yindar Chuo; Kouhyar Tavakolian; Bozena Kaminska
Journal:  J Med Syst       Date:  2009-10-03       Impact factor: 4.460

7.  Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation.

Authors:  Md Mobashir Hasan Shandhi; Beren Semiz; Sinan Hersek; Nazli Goller; Farrokh Ayazi; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2019-01-28       Impact factor: 5.772

8.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

9.  Quantifying and Reducing Motion Artifacts in Wearable Seismocardiogram Measurements During Walking to Assess Left Ventricular Health.

Authors:  Abdul Q Javaid; Hazar Ashouri; Alexis Dorier; Mozziyar Etemadi; J Alex Heller; Shuvo Roy; Omer T Inan
Journal:  IEEE Trans Biomed Eng       Date:  2016-08-16       Impact factor: 4.538

10.  Detecting Aortic Valve-Induced Abnormal Flow with Seismocardiography and Cardiac MRI.

Authors:  Ethan M I Johnson; J Alex Heller; Florencia Garcia Vicente; Roberto Sarnari; Daniel Gordon; Patrick M McCarthy; Alex J Barker; Mozziyar Etemadi; Michael Markl
Journal:  Ann Biomed Eng       Date:  2020-03-16       Impact factor: 3.934