Abstract

A system matrix (SM) is the basic component of iterative image reconstruction algorithms. Calculation of the SM needs a considerable amount of time due to an enormous number of lines of response (LORs) being modeled. In this study, we developed a technique based on a piece-wise calculation method in which symmetry and further division of the voxels are applied. The detector response function for all detectable pairs of photons along certain LORs originating from each voxel is calculated analytically. The total number of LORs in 300 × 300 × 120 voxels (with 2 × 2 × 2 mm(3)) is ~44 billion, and the SM was calculated by the use of three different computers independently; the calculation time was 5 h. The SM took 5 days when calculated by the use of the conventional method (where symmetry and the piece-wise method are not used). The sensitivity correction factor was stored; it had a size of 42 MB in a four-byte computer memory.

Mesh:

Year:  2014        PMID: 25258307     DOI: 10.1007/s12194-014-0293-y

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  15 in total

1.  Three-dimensional image reconstruction for PET by multi-slice rebinning and axial image filtering.

Authors:  R M Lewittt; G Muehllehner; J S Karpt
Journal:  Phys Med Biol       Date:  1994-03       Impact factor: 3.609

2.  Practical considerations for 3-D image reconstruction using spherically symmetric volume elements.

Authors:  S Matej; R M Lewitt
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

3.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

4.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

5.  Fully-3D PET image reconstruction using scanner-independent, adaptive projection data and highly rotation-symmetric voxel assemblies.

Authors:  J J Scheins; H Herzog; N J Shah
Journal:  IEEE Trans Med Imaging       Date:  2011-01-31       Impact factor: 10.048

6.  Efficient methodologies for system matrix modelling in iterative image reconstruction for rotating high-resolution PET.

Authors:  J E Ortuño; G Kontaxakis; J L Rubio; P Guerra; A Santos
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

Review 7.  Advances in PET Image Reconstruction.

Authors:  Andrew J Reader; Habib Zaidi
Journal:  PET Clin       Date:  2008-02-15

8.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography.

Authors:  R Gordon; R Bender; G T Herman
Journal:  J Theor Biol       Date:  1970-12       Impact factor: 2.691

9.  Treatment of axial data in three-dimensional PET.

Authors:  M E Daube-Witherspoon; G Muehllehner
Journal:  J Nucl Med       Date:  1987-11       Impact factor: 10.057

10.  Three-dimensional imaging in the position camera using Fourier techniques.

Authors:  G Chu; K C Tam
Journal:  Phys Med Biol       Date:  1977-03       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.