Literature DB >> 18215890

Practical considerations for 3-D image reconstruction using spherically symmetric volume elements.

S Matej1, R M Lewitt.   

Abstract

Spherically symmetric volume elements with smooth tapering of the values near their boundaries are alternatives to the more conventional voxels for the construction of volume images in the computer. Their use, instead of voxels, introduces additional parameters which enable the user to control the shape of the volume element (blob) and consequently to control the characteristics of the images produced by iterative methods for reconstruction from projection data. For images composed of blobs, efficient algorithms have been designed for the projection and discrete back-projection operations, which are the crucial parts of iterative reconstruction methods. The authors have investigated the relationship between the values of the blob parameters and the properties of images represented by the blobs. Experiments show that using blobs in iterative reconstruction methods leads to substantial improvement in the reconstruction performance, based on visual quality and on quantitative measures, in comparison with the voxel case. The images reconstructed using appropriately chosen blobs are characterized by less image noise for both noiseless data and noisy data, without loss of image resolution.

Year:  1996        PMID: 18215890     DOI: 10.1109/42.481442

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  39 in total

1.  Refraction corrected transmission ultrasound computed tomography for application in breast imaging.

Authors:  Shengying Li; Marcel Jackowski; Donald P Dione; Trond Varslot; Lawrence H Staib; Klaus Mueller
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

2.  On the computational implementation of forward and back-projection operations for cone-beam computed tomography.

Authors:  Davood Karimi; Rabab Ward
Journal:  Med Biol Eng Comput       Date:  2015-10-05       Impact factor: 2.602

3.  Spectral signal-to-noise ratio and resolution assessment of 3D reconstructions.

Authors:  M Unser; C O S Sorzano; P Thévenaz; S Jonić; C El-Bez; S De Carlo; J F Conway; B L Trus
Journal:  J Struct Biol       Date:  2005-03       Impact factor: 2.867

4.  Effect of errors in the system matrix on maximum a posteriori image reconstruction.

Authors:  Jinyi Qi; Ronald H Huesman
Journal:  Phys Med Biol       Date:  2005-07-06       Impact factor: 3.609

5.  Time-of-flight PET image reconstruction using origin ensembles.

Authors:  Christian Wülker; Arkadiusz Sitek; Sven Prevrhal
Journal:  Phys Med Biol       Date:  2015-02-10       Impact factor: 3.609

6.  Subspace-based resolution-enhancing image reconstruction method for few-view differential phase-contrast tomography.

Authors:  Huifeng Guan; Charlotte Klara Hagen; Alessandro Olivo; Mark A Anastasio
Journal:  J Med Imaging (Bellingham)       Date:  2018-06-28

7.  Optimization-based reconstruction of sparse images from few-view projections.

Authors:  Xiao Han; Junguo Bian; Erik L Ritman; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-07-31       Impact factor: 3.609

8.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

9.  Discrete imaging models for three-dimensional optoacoustic tomography using radially symmetric expansion functions.

Authors:  Kun Wang; Robert W Schoonover; Richard Su; Alexander Oraevsky; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2014-05       Impact factor: 10.048

10.  The imaging performance of a LaBr3-based PET scanner.

Authors:  M E Daube-Witherspoon; S Surti; A Perkins; C C M Kyba; R Wiener; M E Werner; R Kulp; J S Karp
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.