Literature DB >> 21292592

Fully-3D PET image reconstruction using scanner-independent, adaptive projection data and highly rotation-symmetric voxel assemblies.

J J Scheins1, H Herzog, N J Shah.   

Abstract

For iterative, fully 3D positron emission tomography (PET) image reconstruction intrinsic symmetries can be used to significantly reduce the size of the system matrix. The precalculation and beneficial memory-resident storage of all nonzero system matrix elements is possible where sufficient compression exists. Thus, reconstruction times can be minimized independently of the used projector and more elaborate weighting schemes, e.g., volume-of-intersection (VOI), are applicable. A novel organization of scanner-independent, adaptive 3D projection data is presented which can be advantageously combined with highly rotation-symmetric voxel assemblies. In this way, significant system matrix compression is achieved. Applications taking into account all physical lines-of-response (LORs) with individual VOI projectors are presented for the Siemens ECAT HR+ whole-body scanner and the Siemens BrainPET, the PET component of a novel hybrid-MR/PET imaging system. Measured and simulated data were reconstructed using the new method with ordered-subset-expectation-maximization (OSEM). Results are compared to those obtained by the sinogram-based OSEM reconstruction provided by the manufacturer. The higher computational effort due to the more accurate image space sampling provides significantly improved images in terms of resolution and noise.

Entities:  

Mesh:

Year:  2011        PMID: 21292592     DOI: 10.1109/TMI.2011.2109732

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  10 in total

1.  Multimodal imaging utilising integrated MR-PET for human brain tumour assessment.

Authors:  Irene Neuner; Joachim B Kaffanke; Karl-Josef Langen; Elena Rota Kops; Lutz Tellmann; Gabriele Stoffels; Christoph Weirich; Christian Filss; Jürgen Scheins; Hans Herzog; N Jon Shah
Journal:  Eur Radiol       Date:  2012-07-11       Impact factor: 5.315

2.  A generalized reconstruction framework for unconventional PET systems.

Authors:  Aswin John Mathews; Ke Li; Sergey Komarov; Qiang Wang; Bosky Ravindranath; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

3.  Fast GPU-based computation of spatial multigrid multiframe LMEM for PET.

Authors:  Moulay Ali Nassiri; Jean-François Carrier; Philippe Després
Journal:  Med Biol Eng Comput       Date:  2015-04-08       Impact factor: 2.602

4.  Pre-computed system matrix calculation based on a piece-wise method for PET.

Authors:  Abdella M Ahmed; Yohei Kikuchi; Shigeo Matsuyama; Atsuki Terakawa; Sodai Takyu; Hiroyuki Sugai; Keizo Ishii
Journal:  Radiol Phys Technol       Date:  2014-09-26

5.  Fast and efficient fully 3D PET image reconstruction using sparse system matrix factorization with GPU acceleration.

Authors:  Jian Zhou; Jinyi Qi
Journal:  Phys Med Biol       Date:  2011-10-21       Impact factor: 3.609

6.  Evaluation of STIR Library Adapted for PET Scanners with Non-Cylindrical Geometry.

Authors:  Viet Dao; Ekaterina Mikhaylova; Max L Ahnen; Jannis Fischer; Kris Thielemans; Charalampos Tsoumpas
Journal:  J Imaging       Date:  2022-06-18

7.  High Performance 3D PET Reconstruction Using Spherical Basis Functions on a Polar Grid.

Authors:  J Cabello; J E Gillam; M Rafecas
Journal:  Int J Biomed Imaging       Date:  2012-04-02

8.  MR-based PET motion correction procedure for simultaneous MR-PET neuroimaging of human brain.

Authors:  Marcus Görge Ullisch; Jürgen Johann Scheins; Christoph Weirich; Elena Rota Kops; Abdullah Celik; Lutz Tellmann; Tony Stöcker; Hans Herzog; Nadim Jon Shah
Journal:  PLoS One       Date:  2012-11-12       Impact factor: 3.240

9.  Effects of regularisation priors on dynamic PET Data.

Authors:  Liliana Caldeira; Juergen Scheins; Nuno da Silva; Michaela Gaens; N Jon Shah
Journal:  EJNMMI Phys       Date:  2014-07

10.  Simultaneous trimodal PET-MR-EEG imaging: Do EEG caps generate artefacts in PET images?

Authors:  Ravichandran Rajkumar; Elena Rota Kops; Jörg Mauler; Lutz Tellmann; Christoph Lerche; Hans Herzog; N Jon Shah; Irene Neuner
Journal:  PLoS One       Date:  2017-09-13       Impact factor: 3.240