Literature DB >> 25242460

Pinless navigation in total knee arthroplasty: navigation reduced by the maximum?

Günther Maderbacher1, Jens Schaumburger, Armin Keshmiri, Magdalena Barthel, Hans-Robert Springorum, Benjamin Craiovan, Joachim Grifka, Clemens Baier.   

Abstract

PURPOSE: Restoring a neutral mechanical axis in total knee arthroplasty (TKA) (within ±3° of varus/valgus) is associated with superior functional outcome and reduced early implant failure. Using conventional alignment jigs results in malalignment in >20 % of cases. In this study, we investigated the reduction of outliers within the threshold of ±3° of leg alignment using a "pinless" navigation system in comparison with conventional alignment jigs investigated.
METHODS: In this randomised prospective study, 80 patients were randomly assigned/allocated to the pinless or conventional control group. After surgery, the two groups were compared regarding outliers > ±3° by means of hip-knee-ankle angle (HKA), mechanical medial proximal tibia angle (mMPTA), mechanical lateral distal femoral angle (mLDFA) and duration of surgery. Student's unpaired t test was used for quantitative variables, Fisher's exact test compared groups (pinless vs. control) and a two-sided p value of ≤0.05 was considered statistically significant.
RESULTS: In the pinless group, outliers regarding HKA and mLDFA > ±3° was significantly reduced (p = 0.025 and p = 0.002 respectively). In the pinless group, the surgery duration was significantly longer (75.6 vs. 64.5 minutes, p < 0.001).
CONCLUSION: Pinless navigation is effective in reducing outliers > ±3° regarding HKA without risking pin-related complications, such as fractures, infections or breaking screws. However, not all tools for conventional navigation in TKA, such as real-time measurements of the tibiofemoral axis and gap balancing, are available.

Entities:  

Mesh:

Year:  2014        PMID: 25242460     DOI: 10.1007/s00264-014-2529-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  24 in total

1.  An anteroposterior axis of the tibia for total knee arthroplasty.

Authors:  Masao Akagi; Masamichi Oh; Tohgo Nonaka; Harutoshi Tsujimoto; Taiyo Asano; Chiaki Hamanishi
Journal:  Clin Orthop Relat Res       Date:  2004-03       Impact factor: 4.176

2.  Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine?

Authors:  Markus Tingart; Christian Lüring; Holger Bäthis; Johannes Beckmann; Joachim Grifka; Lars Perlick
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-09-26       Impact factor: 4.342

3.  Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty.

Authors:  A J Graydon; S Malak; I A Anderson; R P Pitto
Journal:  Int Orthop       Date:  2008-05-28       Impact factor: 3.075

4.  Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties.

Authors:  J H Lonner; M T Laird; S A Stuchin
Journal:  Clin Orthop Relat Res       Date:  1996-10       Impact factor: 4.176

5.  Cutting and implanting errors in minimally invasive total knee arthroplasty using a navigation system.

Authors:  Masahiro Hasegawa; Kakunoshin Yoshida; Hiroki Wakabayashi; Akihiro Sudo
Journal:  Int Orthop       Date:  2012-10-28       Impact factor: 3.075

6.  Pin track induced fractures around computer-assisted TKA.

Authors:  J Beldame; P Boisrenoult; P Beaufils
Journal:  Orthop Traumatol Surg Res       Date:  2010-04-08       Impact factor: 2.256

7.  Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement.

Authors:  Georg Matziolis; Joern Adam; Carsten Perka
Journal:  Arch Orthop Trauma Surg       Date:  2010-02-18       Impact factor: 3.067

8.  Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty.

Authors:  Jerry Yongqiang Chen; Pak Lin Chin; Darren Keng Jin Tay; Shi-Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-03-02       Impact factor: 4.342

9.  Case report : femoral shaft fracture resulting from femoral tracker placement in navigated TKA.

Authors:  Peter Bonutti; Daniel Dethmers; James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2008-02-09       Impact factor: 4.176

10.  Blocked randomization with randomly selected block sizes.

Authors:  Jimmy Efird
Journal:  Int J Environ Res Public Health       Date:  2010-12-23       Impact factor: 3.390

View more
  11 in total

1.  Presence of rotational errors in long leg radiographs after total knee arthroplasty and impact on measured lower limb and component alignment.

Authors:  Günther Maderbacher; Clemens Baier; Achim Benditz; Ferdinand Wagner; Felix Greimel; Joachim Grifka; Armin Keshmiri
Journal:  Int Orthop       Date:  2017-01-31       Impact factor: 3.075

2.  Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error.

Authors:  Csaba Forster-Horvath; Valerie Kremo; Magdalena Müller-Gerbl; Andrej Maria Nowakowski
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

3.  Hand-held navigation may improve accuracy in minimally invasive total knee arthroplasty: a prospective randomized controlled trial.

Authors:  Satit Thiengwittayaporn; Yupadee Fusakul; Nunnapat Kangkano; Chanintorn Jarupongprapa; Narattaphol Charoenphandhu
Journal:  Int Orthop       Date:  2015-07-08       Impact factor: 3.075

4.  Does varus alignment adversely affect implant survival and function six years after kinematically aligned total knee arthroplasty?

Authors:  Stephen M Howell; Stelios Papadopoulos; Kyle Kuznik; Lillian R Ghaly; Maury L Hull
Journal:  Int Orthop       Date:  2015-04-01       Impact factor: 3.075

5.  What is the optimal valgus pre-set for intramedullary femoral alignment rods in total knee arthroplasty?

Authors:  G Maderbacher; A Keshmiri; J Schaumburger; F Zeman; A M Birkenbach; B Craiovan; J Grifka; C Baier
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-06       Impact factor: 4.342

Review 6.  Total knee arthroplasties from the origin to navigation: history, rationale, indications.

Authors:  Dominique Saragaglia; Brice Rubens-Duval; Julia Gaillot; Gabriel Lateur; Régis Pailhé
Journal:  Int Orthop       Date:  2018-03-27       Impact factor: 3.075

7.  Clinical, radiological and survivorship results after ten years comparing navigated and conventional total knee arthroplasty: a matched-pair analysis.

Authors:  Clemens Baier; Jochen Wolfsteiner; Franziska Otto; Florian Zeman; Tobias Renkawitz; Hans-Robert Springorum; Günther Maderbacher; Joachim Grifka
Journal:  Int Orthop       Date:  2017-05-26       Impact factor: 3.075

Review 8.  Current concepts and future perspectives in computer-assisted navigated total knee replacement.

Authors:  Tomoyuki Matsumoto; Naoki Nakano; John E Lawrence; Vikas Khanduja
Journal:  Int Orthop       Date:  2018-05-12       Impact factor: 3.075

9.  Comparison of a novel handheld accelerometer-based navigation system and conventional instrument for performing distal femoral resection in total knee arthroplasty: a randomized controlled trial.

Authors:  Xingquan Xu; Peilai Liu; Zhenfeng Yuan; Dawei Wang; Qunshan Lu; Zhe Zhang; Qing Jiang; Dongquan Shi
Journal:  Ann Transl Med       Date:  2019-11

10.  Pinless Navigation in Unicompartmental Knee Arthroplasty.

Authors:  Sarah Keuntje-Perka; Philipp von Roth; Michael Worlicek; Matthias Koch; Volker Alt; Moritz Kaiser
Journal:  J Clin Med       Date:  2021-05-30       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.