Literature DB >> 25231035

Evaluation of canal transportation and centering ability of K 3 (0.02%) and K 3 (0.04%) with hand K files in primary teeth using spiral computed tomography.

Haridoss Selvakumar1, Vasanthakumari Anandhan, Eapen Thomas, Kavitha Swaminathan, Rajendran Vijayakumar.   

Abstract

BACKGROUND: One of the objectives of root canal preparation is to clean and shape the root canal system while maintaining the original configuration. Therefore, it is important to keep the instruments centered to provide a correct enlargement, without excessive weakening of the root structure. AIM: The aim of the study was to compare canal transportation and centering ability of K 3 (0.02% taper) and K 3 (0.04% taper) with stainless steel hand K files in primary teeth using a spiral computed tomography (SCT) scan.
MATERIALS AND METHODS: A total of 75 extracted mandibular primary second molars was collected. Canals were divided randomly into three groups of 25 teeth each. Group I: K 3 files (0.02% taper), Group II: K 3 (0.04% taper), and Group III: Stainless steel hand K files. Three regions from apical, mid-root, and coronal levels of the canal were recorded. All the teeth were scanned before and after instrumentation by using SCT.
RESULTS: K 3 (0.02% taper) showed less canal transportation and a better centering ratio than K 3 (0.04% taper) and stainless steel hand K files. STATISTICAL ANALYSIS: The mean values were compared between different study groups and the P-value was calculated by using Kruskal-Wallis one-way ANOVA. The Mann-Whitney U-test followed by the Bonferroni correction method was employed to identify the significant groups at the 5% level.
CONCLUSION: K 3 (0.02% taper) shaped root canals without significant shaping errors when compared to K 3 (0.04% taper) and stainless steel hand K files in primary teeth.

Mesh:

Year:  2014        PMID: 25231035     DOI: 10.4103/0970-4388.140943

Source DB:  PubMed          Journal:  J Indian Soc Pedod Prev Dent        ISSN: 0970-4388


  3 in total

1.  Computed Tomographic Evaluation of K3 Rotary and Stainless Steel K File Instrumentation in Primary Teeth.

Authors:  Haridoss Selvakumar; Swaminathan Kavitha; Eapen Thomas; Vasanthakumari Anadhan; Rajendran Vijayakumar
Journal:  J Clin Diagn Res       Date:  2016-01-01

2.  Biomechanical preparation in primary molars using manual and three NiTi instruments: a cone-beam-computed tomographic in vitro study.

Authors:  A Manker; M Solanki; A Tripathi; M L Jain
Journal:  Eur Arch Paediatr Dent       Date:  2019-09-05

3.  Transportation and Centering Ability of Kedo-S Pediatric and Mtwo Instruments in Primary Teeth: A Cone-beam ComputedTomography Study.

Authors:  Selvakumar Haridoss; Keerthana M Rakkesh; Kavitha Swaminathan
Journal:  Int J Clin Pediatr Dent       Date:  2022
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.