Literature DB >> 25223520

The normal mode analysis shape detection method for automated shape determination of lung nodules.

Joseph N Stember1.   

Abstract

Surface morphology and shape in general are important predictors for the behavior of solid-type lung nodules detected on CT. More broadly, shape analysis is useful in many areas of computer-aided diagnosis and essentially all scientific and engineering disciplines. Automated methods for shape detection have all previously, to the author's knowledge, relied on some sort of geometric measure. I introduce Normal Mode Analysis Shape Detection (NMA-SD), an approach that measures shape indirectly via the motion it would undergo if one imagined the shape to be a pseudomolecule. NMA-SD allows users to visualize internal movements in the imaging object and thereby develop an intuition for which motions are important, and which geometric features give rise to them. This can guide the identification of appropriate classification features to distinguish among classes of interest. I employ normal mode analysis (NMA) to animate pseudomolecules representing simulated lung nodules. Doing so, I am able to assign a testing set of nodules into the classes circular, elliptical, and irregular with roughly 97 % accuracy. This represents a proof-of-principle that one can obtain shape information by treating voxels as pseudoatoms in a pseudomolecule, and analyzing the pseudomolecule's predicted motion.

Mesh:

Year:  2015        PMID: 25223520      PMCID: PMC4359205          DOI: 10.1007/s10278-014-9732-x

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  28 in total

1.  The effects of co-occurrence matrix based texture parameters on the classification of solitary pulmonary nodules imaged on computed tomography.

Authors:  M F McNitt-Gray; N Wyckoff; J W Sayre; J G Goldin; D R Aberle
Journal:  Comput Med Imaging Graph       Date:  1999 Nov-Dec       Impact factor: 4.790

2.  Large Amplitude Elastic Motions in Proteins from a Single-Parameter, Atomic Analysis.

Authors: 
Journal:  Phys Rev Lett       Date:  1996-08-26       Impact factor: 9.161

3.  Mega-Dalton biomolecular motion captured from electron microscopy reconstructions.

Authors:  Pablo Chacón; Florence Tama; Willy Wriggers
Journal:  J Mol Biol       Date:  2003-02-14       Impact factor: 5.469

4.  Small pulmonary nodules: volume measurement at chest CT--phantom study.

Authors:  Jane P Ko; Henry Rusinek; Erika L Jacobs; James S Babb; Margrit Betke; Georgeann McGuinness; David P Naidich
Journal:  Radiology       Date:  2003-09       Impact factor: 11.105

5.  Malignant versus benign nodules at CT screening for lung cancer: comparison of thin-section CT findings.

Authors:  Feng Li; Shusuke Sone; Hiroyuki Abe; Heber Macmahon; Kunio Doi
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

Review 6.  CHARMM: the biomolecular simulation program.

Authors:  B R Brooks; C L Brooks; A D Mackerell; L Nilsson; R J Petrella; B Roux; Y Won; G Archontis; C Bartels; S Boresch; A Caflisch; L Caves; Q Cui; A R Dinner; M Feig; S Fischer; J Gao; M Hodoscek; W Im; K Kuczera; T Lazaridis; J Ma; V Ovchinnikov; E Paci; R W Pastor; C B Post; J Z Pu; M Schaefer; B Tidor; R M Venable; H L Woodcock; X Wu; W Yang; D M York; M Karplus
Journal:  J Comput Chem       Date:  2009-07-30       Impact factor: 3.376

7.  A large-scale evaluation of automatic pulmonary nodule detection in chest CT using local image features and k-nearest-neighbour classification.

Authors:  K Murphy; B van Ginneken; A M R Schilham; B J de Hoop; H A Gietema; M Prokop
Journal:  Med Image Anal       Date:  2009-07-30       Impact factor: 8.545

8.  Pulmonary Nodules: growth rate assessment in patients by using serial CT and three-dimensional volumetry.

Authors:  Jane P Ko; Erika J Berman; Manmeen Kaur; James S Babb; Elan Bomsztyk; Alissa K Greenberg; David P Naidich; Henry Rusinek
Journal:  Radiology       Date:  2011-12-09       Impact factor: 11.105

9.  Pulmonary nodules detected at lung cancer screening: interobserver variability of semiautomated volume measurements.

Authors:  Hester A Gietema; Ying Wang; Dongming Xu; Rob J van Klaveren; Harry de Koning; Ernst Scholten; Johny Verschakelen; Gerhard Kohl; Matthijs Oudkerk; Mathias Prokop
Journal:  Radiology       Date:  2006-08-14       Impact factor: 11.105

10.  Quantitative analysis of lesion morphology and texture features for diagnostic prediction in breast MRI.

Authors:  Ke Nie; Jeon-Hor Chen; Hon J Yu; Yong Chu; Orhan Nalcioglu; Min-Ying Su
Journal:  Acad Radiol       Date:  2008-12       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.