Literature DB >> 25216769

Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

Sung Yoon Park1, Chan Kyo Kim, EunJu Kim, Byung Kwan Park.   

Abstract

OBJECTIVES: To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA).
METHODS: Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated.
RESULTS: The overall image quality of NC-MRA was fair or greater in 88% of right and 92% of left renal arteries, while it was 96% in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82% and 100% for reader 1 and 82% and 95% for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA.
CONCLUSION: NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. KEY POINTS: • Accurate pre-treatment evaluation of renal artery anatomy helps clinical decision-making. • NC-MRA using RAVEL offers acceptable imaging quality for renal artery evaluation. • The 3 T RAVEL technique provides excellent diagnostic performance for renal artery evaluation. • The 3 T RAVEL technique may be an alternative to contrast-enhanced MRA.

Mesh:

Substances:

Year:  2014        PMID: 25216769     DOI: 10.1007/s00330-014-3416-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  30 in total

1.  Nonenhanced free-breathing ECG-gated steady-state free precession 3D MR angiography of the renal arteries: comparison between 1.5 T and 3 T.

Authors:  Rotem Shlomo Lanzman; Patric Kröpil; Peter Schmitt; Sonja-Marie Freitag; Adrian Ringelstein; Hans Jörg Wittsack; Dirk Blondin
Journal:  AJR Am J Roentgenol       Date:  2010-03       Impact factor: 3.959

2.  Renal transplant: nonenhanced renal MR angiography with magnetization-prepared steady-state free precession.

Authors:  Xin Liu; Natasha Berg; John Sheehan; Xiaoming Bi; Peter Weale; Renate Jerecic; James Carr
Journal:  Radiology       Date:  2009-03-04       Impact factor: 11.105

Review 3.  Contrast media hypersensitivity--scope of the problem.

Authors:  Knut Brockow
Journal:  Toxicology       Date:  2005-04-15       Impact factor: 4.221

4.  Organ donation and utilization in the United States, 1999-2008.

Authors:  A S Klein; E E Messersmith; L E Ratner; R Kochik; P K Baliga; A O Ojo
Journal:  Am J Transplant       Date:  2010-04       Impact factor: 8.086

5.  Comparison of digital subtraction angiography with gadolinium-enhanced magnetic resonance angiography in the diagnosis of renal artery stenosis.

Authors:  J Thornton; J O'Callaghan; J Walshe; E O'Brien; J C Varghese; M J Lee
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

6.  Incidence of nephrogenic systemic fibrosis after adoption of restrictive gadolinium-based contrast agent guidelines.

Authors:  Yingbing Wang; Tarik K Alkasab; Ozden Narin; Rosalynn M Nazarian; Rathachai Kaewlai; Jonathan Kay; Hani H Abujudeh
Journal:  Radiology       Date:  2011-05-17       Impact factor: 11.105

7.  Renal artery assessment with nonenhanced steady-state free precession versus contrast-enhanced MR angiography.

Authors:  Rolf Wyttenbach; Antonio Braghetti; Michael Wyss; Mario Alerci; Lukas Briner; Paolo Santini; Luca Cozzi; Marcello Di Valentino; Marcus Katoh; Claudio Marone; Peter Vock; Augusto Gallino
Journal:  Radiology       Date:  2007-08-23       Impact factor: 11.105

8.  Multiple arteries in live donor renal transplantation: surgical aspects and outcomes.

Authors:  Bedeir Ali-El-Dein; Yasser Osman; Ahmed A Shokeir; Ahmed B Shehab El-Dein; Hussein Sheashaa; Mohamed A Ghoneim
Journal:  J Urol       Date:  2003-06       Impact factor: 7.450

9.  ECG-gated nonenhanced 3D steady-state free precession MR angiography in assessment of transplant renal arteries: comparison with DSA.

Authors:  Rotem S Lanzman; Adina Voiculescu; Clemens Walther; Adrian Ringelstein; Xiaoming Bi; Peter Schmitt; Sonja-Marie Freitag; Sora Won; Axel Scherer; Dirk Blondin
Journal:  Radiology       Date:  2009-09       Impact factor: 11.105

10.  Renal angiomyolipoma: long-term results following selective arterial embolization.

Authors:  Jacob Ramon; Uri Rimon; Alex Garniek; Gil Golan; Paul Bensaid; Noam D Kitrey; Andrei Nadu; Zohar A Dotan
Journal:  Eur Urol       Date:  2008-04-18       Impact factor: 20.096

View more
  4 in total

1.  Non-enhanced, ECG-gated MR angiography of the pedal vasculature: comparison with contrast-enhanced MR angiography and digital subtraction angiography in peripheral arterial occlusive disease.

Authors:  Tilman Schubert; Martin Takes; Markus Aschwanden; Markus Klarhoefer; Tanja Haas; Augustinus L Jacob; David Liu; Andreas Gutzeit; Sebastian Kos
Journal:  Eur Radiol       Date:  2015-10-29       Impact factor: 5.315

2.  Non-contrast renal MRA using multi-shot gradient echo EPI at 3-T MRI.

Authors:  Kosuke Morita; Takeshi Nakaura; Masami Yoneyama; Yasunori Nagayama; Masafumi Kidoh; Hiroyuki Uetani; Osamu Ikeda; Yasuyuki Yamashita; Toshinori Hirai
Journal:  Eur Radiol       Date:  2021-01-21       Impact factor: 5.315

3.  Non-contrast-enhanced MR angiography using time-spin labelling inversion pulse technique for detecting crossing renal vessels in children with symptomatic ureteropelvic junction obstruction: comparison with surgical findings.

Authors:  Nicolas Brucher; Julie Vial; Christiane Baunin; David Labarre; Olivier Meyrignac; Michel Juricic; Ourdia Bouali; Olivier Abbo; Philippe Galinier; Nicolas Sans
Journal:  Eur Radiol       Date:  2015-10-29       Impact factor: 5.315

4.  Non-contrast MR angiography versus contrast enhanced MR angiography for detection of renal artery stenosis: a comparative analysis in 400 renal arteries.

Authors:  Hira Lal; Rani Kunti Randhir Singh; Priyank Yadav; Ankusha Yadav; Dharmendra Bhadauria; Anuradha Singh
Journal:  Abdom Radiol (NY)       Date:  2020-11-02
  4 in total