Literature DB >> 25211313

A comparison of radiation dose between standard and 3D angiography in congenital heart disease.

João Luiz Langer Manica, Mônica Scott Borges, Rogério Fachel de Medeiros, Leandro dos Santos Fischer, Gabriel Broetto, Raul Ivo Rossi Filho.   

Abstract

BACKGROUND: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available.
OBJECTIVES: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA).
METHODS: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP).
RESULTS: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions.
CONCLUSIONS: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.

Entities:  

Mesh:

Year:  2014        PMID: 25211313      PMCID: PMC4150664          DOI: 10.5935/abc.20140118

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.000


  20 in total

1.  Three-dimensional digital angiography: new tool for simultaneous three-dimensional rendering of vascular and osseous information during rotational angiography.

Authors:  Philippe Gailloud; Satoru Oishi; Jeffrey Carpenter; Kieran J Murphy
Journal:  AJNR Am J Neuroradiol       Date:  2004-04       Impact factor: 3.825

2.  Greater radiation savings at higher body mass indexes with dual axis rotational coronary angiography.

Authors:  Victor Grech; Marvin Grech; Joseph Debono; Robert G Xuereb; Albert Fenech
Journal:  Catheter Cardiovasc Interv       Date:  2012-12-12       Impact factor: 2.692

3.  Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization.

Authors:  Klaus Bacher; Evelien Bogaert; Régine Lapere; Daniël De Wolf; Hubert Thierens
Journal:  Circulation       Date:  2004-12-20       Impact factor: 29.690

4.  Patient dose from 3D rotational neurovascular studies.

Authors:  R R Bridcut; E Murphy; A Workman; P Flynn; R J Winder
Journal:  Br J Radiol       Date:  2007-01-03       Impact factor: 3.039

5.  Rotational X-ray coronary angiography.

Authors:  Subha V Raman; Ronald Morford; Matthew Neff; Talal T Attar; Gilbert Kukielka; Raymond D Magorien; Charles A Bush
Journal:  Catheter Cardiovasc Interv       Date:  2004-10       Impact factor: 2.692

6.  Randomized study of the safety and clinical utility of rotational vs. standard coronary angiography using a flat-panel detector.

Authors:  Mateen Akhtar; Kalpesh T Vakharia; Jacob Mishell; Atul Gera; Thomas A Ports; Yerem Yeghiazarians; Andrew D Michaels
Journal:  Catheter Cardiovasc Interv       Date:  2005-09       Impact factor: 2.692

7.  Three-dimensional rotational angiography of the left atrium and esophagus--A virtual computed tomography scan in the electrophysiology lab?

Authors:  Michael V Orlov; Peter Hoffmeister; G Muqtada Chaudhry; Ibrahim Almasry; Geert H M Gijsbers; Tammee Swack; Charles I Haffajee
Journal:  Heart Rhythm       Date:  2006-10-13       Impact factor: 6.343

8.  Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms.

Authors:  U Missler; C Hundt; M Wiesmann; T Mayer; H Brückmann
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

9.  Randomized study of the safety and clinical utility of rotational angiography versus standard angiography in the diagnosis of coronary artery disease.

Authors:  James T Maddux; Onno Wink; John C Messenger; Bertron M Groves; Robert Liao; Jodi Strzelczyk; Shiuh-Yung Chen; John D Carroll
Journal:  Catheter Cardiovasc Interv       Date:  2004-06       Impact factor: 2.692

10.  Three-dimensional rotational digital angiography in a complicated case of patent ductus arteriosus transcatheter closure.

Authors:  Gianluca Rigatelli; Alberto Zamboni; Paolo Cardaioli
Journal:  Catheter Cardiovasc Interv       Date:  2007-11-15       Impact factor: 2.692

View more
  7 in total

1.  Radiation Exposure by Three-Dimensional Rotational Angiography (3DRA) During Trans-catheter Melody Pulmonary Valve Procedures (TMPV) in a Pediatric Cardiac Catheterization Laboratory.

Authors:  Hoang H Nguyen; David T Balzer; Joshua J Murphy; Ramzi Nicolas; Shabana Shahanavaz
Journal:  Pediatr Cardiol       Date:  2016-07-25       Impact factor: 1.655

Review 2.  Pros, cons and future perspectives - three questions on three dimensional guidance for cardiac catheterization in congenital heart disease.

Authors:  Sebastian Góreczny; Gregor Krings; Ziyad M Hijazi; Thomas Fagan; Darren Berman; Damien Kenny; Gareth J Morgan
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-09-04       Impact factor: 1.426

3.  Three-dimensional rotational angiography in children with an aortic coarctation.

Authors:  N L P Starmans; G J Krings; M M C Molenschot; F van der Stelt; J M P J Breur
Journal:  Neth Heart J       Date:  2016-11       Impact factor: 2.380

Review 4.  Recent advances in cardiac catheterization for congenital heart disease.

Authors:  Sok-Leng Kang; Lee Benson
Journal:  F1000Res       Date:  2018-03-26

5.  Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol.

Authors:  Savine C S Minderhoud; Femke van der Stelt; Mirella M C Molenschot; Michel S Koster; Gregor J Krings; Johannes M P J Breur
Journal:  Pediatr Cardiol       Date:  2018-08-03       Impact factor: 1.655

6.  Three-Dimensional Rotational Angiography during Catheterization of Congenital Heart Disease - A ten Years' experience at a single center.

Authors:  Stefanie Söder; Wolfgang Wällisch; Sven Dittrich; Robert Cesnjevar; Jean-Pierre Pfammatter; Martin Glöckler
Journal:  Sci Rep       Date:  2020-04-24       Impact factor: 4.379

Review 7.  Percutaneous Pulmonary Valve Implantation.

Authors:  Luca Giugno; Alessia Faccini; Mario Carminati
Journal:  Korean Circ J       Date:  2020-04       Impact factor: 3.243

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.