Literature DB >> 17202197

Patient dose from 3D rotational neurovascular studies.

R R Bridcut1, E Murphy, A Workman, P Flynn, R J Winder.   

Abstract

The use of image-guided interventional radiological techniques is increasing in prevalence and complexity. Imaging system developments have helped improve the information available to interventionalists to plan and guide procedures. Information on doses to patients resulting from alternative imaging techniques or protocols is useful for both the process of justifying particular procedures and in optimizing the resultant exposures. Such information is not always available, especially for new or developing imaging techniques. We have undertaken a study of doses to patients associated with two alternative imaging methods for pre-intervention assessment of intracranial aneurysms. In the first technique the aneurysm is assessed from a series of digital subtraction angiography (DSA) runs taken at different imaging projections. The second technique involved acquiring images from one single image run while the imaging system rotated 180 degrees around the patient's head. In this technique, the aneurysm was then evaluated from a 3D reconstruction of the projection images. Effective doses were calculated using a computer model to simulate the exposure geometry and parameters. The mean dose from the DSA protocol used at our centre was 3.4 mSv and from the 3D rotational angiography (RA) technique was 0.20 mSv.

Entities:  

Mesh:

Year:  2007        PMID: 17202197     DOI: 10.1259/bjr/95349672

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  A comparison of radiation exposure between diagnostic CTA and DSA examinations of cerebral and cervicocerebral vessels.

Authors:  A-L Manninen; J-M Isokangas; A Karttunen; T Siniluoto; M T Nieminen
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-14       Impact factor: 3.825

2.  Dose comparison of classical 2-plane DSA and 3D rotational angiography for the assessment of intracranial aneurysms.

Authors:  N Guberina; U Lechel; M Forsting; C Mönninghoff; U Dietrich; A Ringelstein
Journal:  Neuroradiology       Date:  2016-03-12       Impact factor: 2.804

3.  A comparison of radiation dose between standard and 3D angiography in congenital heart disease.

Authors:  João Luiz Langer Manica; Mônica Scott Borges; Rogério Fachel de Medeiros; Leandro dos Santos Fischer; Gabriel Broetto; Raul Ivo Rossi Filho
Journal:  Arq Bras Cardiol       Date:  2014-08       Impact factor: 2.000

4.  Effect of ROI filtering in 3D cone-beam rotational angiography on organ dose and effective dose in cerebral investigations.

Authors:  Fabian Göpfert; Ralph Schmidt; Jörg Wulff; Klemens Zink
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.