Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization.

Klaus Bacher1, Evelien Bogaert, Régine Lapere, Daniël De Wolf, Hubert Thierens.   

Abstract

BACKGROUND: Because of the higher radiosensitivity of infants and children compared with adults, there is a need to evaluate the doses delivered to pediatric patients who undergo interventional cardiac procedures. However, knowledge of the effective dose in pediatric interventional cardiology is very limited. METHODS AND
RESULTS: For an accurate risk estimation, a patient-specific Monte Carlo simulation of the effective dose was set up in 60 patients with congenital heart disease who underwent diagnostic (n=28) or therapeutic (n=32) cardiac catheterization procedures. The dose-saving effect of using extra copper filtration in the x-ray beam was also investigated. For diagnostic cardiac catheterizations, a median effective dose of 4.6 mSv was found. Therapeutic procedures resulted in a higher median effective dose of 6.0 mSv because of the prolonged use of fluoroscopy. The overall effect of inserting extra copper filtration into the x-ray beam was a total effective dose reduction of 18% with no detrimental effect on image quality. An excellent correlation between the dose-area product and effective patient dose was found (r=0.95). Hence, dose-area product is suitable for online estimation of the effective dose with good accuracy. With all procedures included, the resulting median lifetime risk for stochastic effects was 0.08%.
CONCLUSIONS: Because of the high radiation exposure, it is important to monitor patient dose by dose-area product instrumentation and to use additional beam filtration to keep the effective dose as low as possible in view of the sensitivity of the pediatric patients.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15611374     DOI: 10.1161/01.CIR.0000151098.52656.3A

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  64 in total

1.  Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience.

Authors:  Zhaoping Cheng; Ximing Wang; Yanhua Duan; Lebin Wu; Dawei Wu; Baoting Chao; Cheng Liu; Zhuodong Xu; Hongxin Li; Fei Liang; Jian Xu; Jiuhong Chen
Journal:  Eur Radiol       Date:  2010-06-09       Impact factor: 5.315

2.  X-ray dose from pediatric cardiac catheterization: a comparison of materials and methods for measurement or calculation.

Authors:  Brent Herron; John Strain; Thomas Fagan; Linda Wright; Heather Shockley
Journal:  Pediatr Cardiol       Date:  2010-08-10       Impact factor: 1.655

3.  Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan.

Authors:  Hyun Woo Goo; Dong Hyun Yang
Journal:  Pediatr Radiol       Date:  2010-05-13

4.  Radiation Risk Categories in Cardiac Catheterization for Congenital Heart Disease: A Tool to Aid in the Evaluation of Radiation Outcomes.

Authors:  Brian P Quinn; Aimee K Armstrong; Holly D Bauser-Heaton; Ryan Callahan; Howaida G El-Said; Susan R Foerster; Bryan H Goldstein; Andrea S Goodman; Todd M Gudausky; Jacqueline N Kreutzer; Ryan A Leahy; Christopher J Petit; Toby A Rockefeller; Shabana Shahanavaz; Sara M Trucco; Lisa Bergersen
Journal:  Pediatr Cardiol       Date:  2018-11-30       Impact factor: 1.655

5.  Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease.

Authors:  Yuzo Yamasaki; Satoshi Kawanami; Takeshi Kamitani; Koji Sagiyama; Seitaro Shin; Takuya Hino; Hazumu Nagata; Hidetake Yabuuchi; Michinobu Nagao; Hiroshi Honda
Journal:  Int J Cardiovasc Imaging       Date:  2018-05-05       Impact factor: 2.357

6.  Radiofrequency ablation of right ventricular outflow tract tachycardia using a magnetic resonance 3D model for interactive catheter guidance.

Authors:  G F Greil; M Gass; V Kuehlkamp; R M Botnar; I Wolf; S Miller; L Sieverding
Journal:  Clin Res Cardiol       Date:  2006-09-28       Impact factor: 5.460

7.  Assessment of modified Blalock-Taussig shunt in children with congenital heart disease using multidetector-row computed tomography.

Authors:  Manal Mohamed Helmy Nabo; Yasunobu Hayabuchi; Miki Inoue; Noriko Watanabe; Miho Sakata; Shoji Kagami
Journal:  Heart Vessels       Date:  2010-09-28       Impact factor: 2.037

8.  Estimation of radiation dose and risk to children undergoing cardiac catheterization for the treatment of a congenital heart disease using Monte Carlo simulations.

Authors:  Emmanuel Yakoumakis; Helen Kostopoulou; Triantafilia Makri; Anastastios Dimitriadis; Evaggelos Georgiou; Ioannis Tsalafoutas
Journal:  Pediatr Radiol       Date:  2012-10-24

9.  Radiation dose to the brain and subsequent risk of developing brain tumors in pediatric patients undergoing interventional neuroradiology procedures.

Authors:  I Thierry-Chef; S L Simon; C E Land; D L Miller
Journal:  Radiat Res       Date:  2008-11       Impact factor: 2.841

10.  Radiation safety protocol using real-time dose reporting reduces patient exposure in pediatric electrophysiology procedures.

Authors:  Akash R Patel; Jamie Ganley; Xiaowei Zhu; Jonathan J Rome; Maully Shah; Andrew C Glatz
Journal:  Pediatr Cardiol       Date:  2014-05-07       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.