A comparison of two pulmonary artery mixed venous oxygen saturation catheters during the changing conditions of cardiac surgery.

B R Hecker1, D L Brown, D Wilson.   

Abstract

Continuous mixed venous oxygen saturation (SvO2), using modified pulmonary artery (PA) catheters, can assist in the management of cardiac surgery patients. Two FDA-approved catheters are available for SvO2 monitoring. One system uses two wavelengths of light and the other is a three-wavelength system. The present study was designed to determine the accuracy of the two catheters during cardiac surgery. Sixty-five consecutive patients were assigned to one of the two catheter groups. Data were collected pre- and post-induction, after sternotomy, and after extracorporeal circulation. An updated hematocrit was entered in the two-wavelength system preceding the last two measurements. Patient demographics, severity of preoperative cardiac disease, and intraoperative hemodynamics were comparable between groups. Two-wavelength determinations varied inconsistently from cooximeter values, while three-wavelength measurements did not differ significantly. Changes in hematocrit were responsible in part for the variability in two-wavelength measurements. In summary, three-wavelength measurements by the Shaw system were more accurate than two-wavelength measurements by the Edwards system.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2520649     DOI: 10.1016/0888-6296(89)90106-3

Source DB:  PubMed          Journal:  J Cardiothorac Anesth        ISSN: 0888-6296


  5 in total

1.  Accuracy of continuous central venous oxygen saturation monitoring in patients undergoing cardiac surgery.

Authors:  Werner Baulig; Alexander Dullenkopf; Andreas Kobler; Barbara Baulig; Hans Rudolf Roth; Edith R Schmid
Journal:  J Clin Monit Comput       Date:  2008-04-29       Impact factor: 2.502

2.  Simultaneous in vivo comparison of two-versus three-wavelength mixed venous (Svo2) oximetry catheters.

Authors:  F Bongard; T S Lee; T Leighton; S Y Liu
Journal:  J Clin Monit       Date:  1995-09

Review 3.  Monitoring during paediatric cardiac anaesthesia.

Authors:  J P Purday
Journal:  Can J Anaesth       Date:  1994-09       Impact factor: 5.063

4.  In vitro accuracy of three blood O2 saturation optic catheter systems.

Authors:  G Janvier; H Guenard; A M Lomenech
Journal:  Intensive Care Med       Date:  1994-08       Impact factor: 17.440

5.  Accuracy assessment for three fiberoptic pulmonary artery catheters for SvO2 monitoring.

Authors:  A Armaganidis; J F Dhainaut; J L Billard; K Klouche; J P Mira; F Brunet; A T Dinh-Xuan; J Dall'Ava-Santucci
Journal:  Intensive Care Med       Date:  1994-08       Impact factor: 17.440

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.