Literature DB >> 25204985

Quartz in coal dust deposited on internal surface of respirable size selective samplers.

Jhy-Charm Soo1, Taekhee Lee, Michael Kashon, Mohannad Kusti, Martin Harper.   

Abstract

The objective of the present study is to quantify quartz mass in coal dust deposited on the internal cassette surface of respirable size-selective samplers. Coal dust was collected with four different respirable size-selective samplers (10 mm Dorr-Oliver nylon [Sensidyne, St. Petersburg, Fla.], SKC Aluminum [SKC Inc., Eighty Four, Pa.], BGI4L [BGI USA Inc., Waltham, Mass.], and GK2.69 cyclones [BGI USA Inc.]) with two different cassette types (polystyrene and static-dissipative polypropylene cassettes). The coal dust was aerosolized in a calm air chamber by using a fluidized bed aerosol generator without neutralization under the assumption that the procedure is similar to field sampling conditions. The mass of coal dust was measured gravimetrically and quartz mass was determined by Fourier transform infrared spectroscopy according to the National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods, Method 7603. The mass fractions of the total quartz sample on the internal cassette surface are significantly different between polystyrene and static-dissipative cassettes for all cyclones (p < 0.05). No consistent relationship between quartz mass on cassette internal surface and coal dust filter mass was observed. The BGI4L cyclone showed a higher (but not significantly) and the GK2.69 cyclone showed a significantly lower (p < 0.05) internal surface deposit quartz mass fraction for polystyrene cassettes compared to other cyclones. This study confirms previous observations that the interior surface deposits in polystyrene cassettes attached to cyclone pre-selectors can be a substantial part of the sample, and therefore need to be included in any analysis for accurate exposure assessment. On the other hand, the research presented here supports the position that the internal surface deposits in static-dissipative cassettes used with size-selective cyclones are negligible and that it is only necessary to analyze the filter catch.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25204985      PMCID: PMC4733624          DOI: 10.1080/15459624.2014.960575

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  11 in total

1.  Use of membrane filters in air sampling.

Authors:  H J PAULUS; N A TALVITIE; D A FRASER; R G KEENAN
Journal:  Am Ind Hyg Assoc Q       Date:  1957-09

2.  Quartz measurement in coal dust with high-flow rate samplers: laboratory study.

Authors:  Taekhee Lee; Eun Gyung Lee; Seung Won Kim; William P Chisholm; Michael Kashon; Martin Harper
Journal:  Ann Occup Hyg       Date:  2011-12-19

3.  Concerning sampler wall deposits in the chemical analysis of airborne metals.

Authors:  Martin Harper; Martine Demange
Journal:  J Occup Environ Hyg       Date:  2007-09       Impact factor: 2.155

4.  Size-selective samplers for estimating "respirable" dust concentrations.

Authors:  M LIPPMANN; W B HARRIS
Journal:  Health Phys       Date:  1962 Mar-Apr       Impact factor: 1.316

Review 5.  Electrostatic effects in asbestos sampling. I: Experimental measurements.

Authors:  P A Baron; G J Deye
Journal:  Am Ind Hyg Assoc J       Date:  1990-02

Review 6.  The real issue with wall deposits in closed filter cassettes--what's the sample?

Authors:  Michael J Brisson; Melecita M Archuleta
Journal:  J Occup Environ Hyg       Date:  2009-12       Impact factor: 2.155

7.  Closed-face filter cassette (CFC) sampling-guidance on procedures for inclusion of material adhering to internal sampler surfaces.

Authors:  Kevin Ashley; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

8.  Problems associated with the use of membrane filters for dust sampling when compositonal analysis is required.

Authors:  D Mark
Journal:  Ann Occup Hyg       Date:  1974-08

9.  Calibration of two-stage air samplers.

Authors:  H J Ettinger; J E Partridge; G W Royer
Journal:  Am Ind Hyg Assoc J       Date:  1970 Sep-Oct

10.  Measurements of electric charge for workplace aerosols.

Authors:  A M Johnston; J H Vincent; A D Jones
Journal:  Ann Occup Hyg       Date:  1985
View more
  8 in total

1.  A New Miniature Respirable Sampler for In-mask Sampling: Part 1-Particle Size Selection Performance.

Authors:  Peter Stacey; Andrew Thorpe; Rhiannon Mogridge; Taekhee Lee; Martin Harper
Journal:  Ann Occup Hyg       Date:  2016-09-14

2.  Collection and Extraction of Occupational Air Samples for Analysis of Fungal DNA.

Authors:  Angela R Lemons; William G Lindsley; Brett J Green
Journal:  J Vis Exp       Date:  2018-05-02       Impact factor: 1.355

3.  Laboratory comparison of new high flow rate respirable size-selective sampler.

Authors:  Taekhee Lee; Andrew Thorpe; Emanuele Cauda; Leah Tipton; Wayne T Sanderson; Alan Echt
Journal:  J Occup Environ Hyg       Date:  2018-10       Impact factor: 2.155

4.  Respirable size-selective sampler for end-of-shift quartz measurement: Development and performance.

Authors:  Taekhee Lee; Larry Lee; Emanuele Cauda; Jon Hummer; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2017-05       Impact factor: 2.155

5.  Replacement of filters for respirable quartz measurement in coal mine dust by infrared spectroscopy.

Authors:  Daniel Farcas; Taekhee Lee; William P Chisholm; Jhy-Charm Soo; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

6.  Silica Measurement with High Flow Rate Respirable Size Selective Samplers: A Field Study.

Authors:  Taekhee Lee; Martin Harper; Michael Kashon; Larry A Lee; Catherine B Healy; Marie A Coggins; Pam Susi; Andrew O'Brien
Journal:  Ann Occup Hyg       Date:  2015-11-24

7.  Treated and untreated rock dust: Quartz content and physical characterization.

Authors:  Jhy-Charm Soo; Taekhee Lee; William P Chisholm; Daniel Farcas; Diane Schwegler-Berry; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2016-11       Impact factor: 2.155

8.  Promoting early exposure monitoring for respirable crystalline silica: Taking the laboratory to the mine site.

Authors:  Emanuele Cauda; Arthur Miller; Pamela Drake
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.