Literature DB >> 17613720

Concerning sampler wall deposits in the chemical analysis of airborne metals.

Martin Harper1, Martine Demange.   

Abstract

Mesh:

Substances:

Year:  2007        PMID: 17613720     DOI: 10.1080/15459620701493149

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


× No keyword cloud information.
  12 in total

1.  Solid versus liquid particle sampling efficiency of three personal aerosol samplers when facing the wind.

Authors:  Kirsten A Koehler; T Renee Anthony; Michael Van Dyke; John Volckens
Journal:  Ann Occup Hyg       Date:  2011-09-29

2.  Preliminary studies on the use of acid-soluble cellulose acetate internal capsules for workplace metals sampling and analysis.

Authors:  Martin Harper; Kevin Ashley
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

3.  Comparison of lead and tin concentrations in air at a solder manufacturer from the closed-face 37-mm cassette with and without a custom cellulose-acetate cassette insert.

Authors:  Eun Gyung Lee; William P Chisholm; Dru A Burns; John H Nelson; Michael L Kashon; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

4.  Closed-face filter cassette (CFC) sampling-guidance on procedures for inclusion of material adhering to internal sampler surfaces.

Authors:  Kevin Ashley; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

5.  Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules.

Authors:  Sean O'Connor; Paula Fey O'Connor; H Amy Feng; Kevin Ashley
Journal:  Gefahrst Reinhalt Luft       Date:  2014-10       Impact factor: 0.323

6.  Comparison of a Wipe Method With and Without a Rinse to Recover Wall Losses in Closed Face 37-mm Cassettes used for Sampling Lead Dust Particulates.

Authors:  Diana Ceballos; Bradley King; Catherine Beaucham; Scott E Brueck
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

7.  Interlaboratory evaluation of cellulosic acid-soluble internal air sampling capsules for multi-element analysis.

Authors:  Ronnee N Andrews; H Amy Feng; Kevin Ashley
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

8.  Quartz in coal dust deposited on internal surface of respirable size selective samplers.

Authors:  Jhy-Charm Soo; Taekhee Lee; Michael Kashon; Mohannad Kusti; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

9.  Acid-soluble internal capsules for closed-face cassette elemental sampling and analysis of workplace air.

Authors:  Martin Harper; Kevin Ashley
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

10.  Wood dust sampling: field evaluation of personal samplers when large particles are present.

Authors:  Taekhee Lee; Martin Harper; James E Slaven; Kiyoung Lee; Roy J Rando; Elizabeth H Maples
Journal:  Ann Occup Hyg       Date:  2010-10-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.