Literature DB >> 26608952

Silica Measurement with High Flow Rate Respirable Size Selective Samplers: A Field Study.

Taekhee Lee1, Martin Harper2, Michael Kashon3, Larry A Lee2, Catherine B Healy4, Marie A Coggins4, Pam Susi5, Andrew O'Brien6.   

Abstract

High and low flow rate respirable size selective samplers including the CIP10-R (10 l min(-1)), FSP10 (11.2 l min(-1)), GK2.69 (4.4 l min(-1)), 10-mm nylon (1.7 l min(-1)), and Higgins-Dewell type (2.2 l min(-1)) were compared via side-by-side sampling in workplaces for respirable crystalline silica measurement. Sampling was conducted at eight different occupational sites in the USA and five different stonemasonry sites in Ireland. A total of 536 (268 pairs) personal samples and 55 area samples were collected. Gravimetric analysis was used to determine respirable dust mass and X-ray diffraction analysis was used to determine quartz mass. Ratios of respirable dust mass concentration, quartz mass concentration, respirable dust mass, and quartz mass from high and low flow rate samplers were compared. In general, samplers did not show significant differences greater than 30% in respirable dust mass concentration and quartz mass concentration when outliers (ratio <0.3 or >3.0) were removed from the analysis. The frequency of samples above the limit of detection and limit of quantification of quartz was significantly higher for the CIP10-R and FSP10 samplers compared to low flow rate samplers, while the GK2.69 cyclone did not show significant difference from low flow rate samplers. High flow rate samplers collected significantly more respirable dust and quartz than low flow rate samplers as expected indicating that utilizing high flow rate samplers might improve precision in quartz measurement. Although the samplers did not show significant differences in respirable dust and quartz concentrations, other practical attributes might make them more or less suitable for personal sampling. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2015.

Entities:  

Keywords:  CIP10-R; FSP10; GK2.69; high flow rate samplers; quartz; silica

Mesh:

Substances:

Year:  2015        PMID: 26608952      PMCID: PMC4779386          DOI: 10.1093/annhyg/mev081

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  14 in total

1.  Study of fifteen respirable aerosol samplers used in occupational hygiene.

Authors:  P Görner; R Wrobel; V Micka; V Skoda; J Denis; J F Fabriès
Journal:  Ann Occup Hyg       Date:  2001-01

2.  Quartz measurement in coal dust with high-flow rate samplers: laboratory study.

Authors:  Taekhee Lee; Eun Gyung Lee; Seung Won Kim; William P Chisholm; Michael Kashon; Martin Harper
Journal:  Ann Occup Hyg       Date:  2011-12-19

3.  Field comparison of personal samplers for inhalable dust.

Authors:  N P Vaughan; C P Chalmers; R A Botham
Journal:  Ann Occup Hyg       Date:  1990-12

4.  The performance of passive diffusion monitors for organic vapours for personal sampling of painters.

Authors:  J F van der Wal; A Moerkerken
Journal:  Ann Occup Hyg       Date:  1984

5.  A comparison of the performance of samplers for respirable dust in workplaces and laboratory analysis for respirable quartz.

Authors:  Steven Verpaele; Jonathan Jouret
Journal:  Ann Occup Hyg       Date:  2012-07-23

6.  Performance of high flow rate samplers for respirable particle collection.

Authors:  Taekhee Lee; Seung Won Kim; William P Chisholm; James Slaven; Martin Harper
Journal:  Ann Occup Hyg       Date:  2010-07-21

7.  Assessment of respirable crystalline silica analysis using Proficiency Analytical Testing results from 2003-2013.

Authors:  Martin Harper; Khatchatur Sarkisian; Michael Andrew
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

8.  Performance of High-Flow-Rate Samplers for Respirable Crystalline Silica Measurement Under Field Conditions: Preliminary Study.

Authors:  Marie A Coggins; Catherine B Healy; Taekhee Lee; Martin Harper
Journal:  Silica Assoc Respirable Miner Part (2012)       Date:  2014-01

9.  Quartz in coal dust deposited on internal surface of respirable size selective samplers.

Authors:  Jhy-Charm Soo; Taekhee Lee; Michael Kashon; Mohannad Kusti; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

10.  Wood dust sampling: field evaluation of personal samplers when large particles are present.

Authors:  Taekhee Lee; Martin Harper; James E Slaven; Kiyoung Lee; Roy J Rando; Elizabeth H Maples
Journal:  Ann Occup Hyg       Date:  2010-10-29
View more
  2 in total

1.  Laboratory comparison of new high flow rate respirable size-selective sampler.

Authors:  Taekhee Lee; Andrew Thorpe; Emanuele Cauda; Leah Tipton; Wayne T Sanderson; Alan Echt
Journal:  J Occup Environ Hyg       Date:  2018-10       Impact factor: 2.155

2.  Calibration of high flow rate thoracic-size selective samplers.

Authors:  Taekhee Lee; Andrew Thorpe; Emanuele Cauda; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.