Literature DB >> 25199902

Depth-resolved surface coil MRS (DRESS)-localized dynamic (31) P-MRS of the exercising human gastrocnemius muscle at 7 T.

Ladislav Valkovič1, Marek Chmelík, Ivica Just Kukurová, Michaela Jakubová, Monika Christina Kipfelsberger, Patrik Krumpolec, Marjeta Tušek Jelenc, Wolfgang Bogner, Martin Meyerspeer, Jozef Ukropec, Ivan Frollo, Barbara Ukropcová, Siegfried Trattnig, Martin Krššák.   

Abstract

Dynamic (31) P-MRS with sufficiently high temporal resolution enables the non-invasive evaluation of oxidative muscle metabolism through the measurement of phosphocreatine (PCr) recovery after exercise. Recently, single-voxel localized (31) P-MRS was compared with surface coil localization in a dynamic fashion, and was shown to provide higher anatomical and physiological specificity. However, the relatively long TE needed for the single-voxel localization scheme with adiabatic pulses limits the quantification of J-coupled spin systems [e.g. adenosine triphosphate (ATP)]. Therefore, the aim of this study was to evaluate depth-resolved surface coil MRS (DRESS) as an alternative localization method capable of free induction decay (FID) acquisition for dynamic (31) P-MRS at 7 T. The localization performance of the DRESS sequence was tested in a phantom. Subsequently, two dynamic examinations of plantar flexions at 25% of maximum voluntary contraction were conducted in 10 volunteers, one examination with and one without spatial localization. The DRESS slab was positioned obliquely over the gastrocnemius medialis muscle, avoiding other calf muscles. Under the same load, significant differences in PCr signal drop (31.2 ± 16.0% versus 43.3 ± 23.4%), end exercise pH (7.06 ± 0.02 versus 6.96 ± 0.11), initial recovery rate (0.24 ± 0.13 mm/s versus 0.35 ± 0.18 mm/s) and maximum oxidative flux (0.41 ± 0.14 mm/s versus 0.54 ± 0.16 mm/s) were found between the non-localized and DRESS-localized data, respectively. Splitting of the inorganic phosphate (Pi) signal was observed in several non-localized datasets, but in none of the DRESS-localized datasets. Our results suggest that the application of the DRESS localization scheme yielded good spatial selection, and provided muscle-specific insight into oxidative metabolism, even at a relatively low exercise load. In addition, the non-echo-based FID acquisition allowed for reliable detection of ATP resonances, and therefore calculation of the specific maximum oxidative flux, in the gastrocnemius medialis using standard assumptions about resting ATP concentration in skeletal muscle.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  7 T; DRESS localization; dynamic 31P-MRS; energy metabolism; gastrocnemius muscle

Mesh:

Substances:

Year:  2014        PMID: 25199902     DOI: 10.1002/nbm.3196

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  19 in total

Review 1.  Assessing tissue metabolism by phosphorous-31 magnetic resonance spectroscopy and imaging: a methodology review.

Authors:  Yuchi Liu; Yuning Gu; Xin Yu
Journal:  Quant Imaging Med Surg       Date:  2017-12

Review 2.  MR compatible ergometers for dynamic 31P MRS.

Authors:  Petr Sedivy; Monika Dezortova; Jan Rydlo; Miloslav Drobny; Martin Krssak; Ladislav Valkovic; Milan Hajek
Journal:  J Appl Biomed       Date:  2019-04-15       Impact factor: 1.797

3.  Dynamic phosphocreatine imaging with unlocalized pH assessment of the human lower leg muscle following exercise at 3T.

Authors:  Oleksandr Khegai; Guillaume Madelin; Ryan Brown; Prodromos Parasoglou
Journal:  Magn Reson Med       Date:  2017-05-30       Impact factor: 4.668

4.  High-Resolution Dynamic 31P-MR Spectroscopic Imaging for Mapping Mitochondrial Function.

Authors:  Bryan Clifford; Yuning Gu; Yuchi Liu; Kihwan Kim; Sherry Huang; Yudu Li; Fan Lam; Zhi-Pei Liang; Xin Yu
Journal:  IEEE Trans Biomed Eng       Date:  2020-01-28       Impact factor: 4.538

5.  Localized semi-LASER dynamic (31)P magnetic resonance spectroscopy of the soleus during and following exercise at 7 T.

Authors:  Georg B Fiedler; Martin Meyerspeer; Albrecht I Schmid; Sigrun Goluch; Kiril Schewzow; Elmar Laistler; Arash Mirzahosseini; Fabian Niess; Ewald Unger; Michael Wolzt; Ewald Moser
Journal:  MAGMA       Date:  2015-04-18       Impact factor: 2.310

6.  Recovery kinetics of creatine in mild plantar flexion exercise using 3D creatine CEST imaging at 7 Tesla.

Authors:  Dushyant Kumar; Ravi Prakash Reddy Nanga; Deepa Thakuri; Neil Wilson; Abigail Cember; Melissa Lynne Martin; Dan Zhu; Russell T Shinohara; Qin Qin; Hari Hariharan; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2020-08-15       Impact factor: 4.668

7.  Feasibility and repeatability of localized (31) P-MRS four-angle saturation transfer (FAST) of the human gastrocnemius muscle using a surface coil at 7 T.

Authors:  Marjeta Tušek Jelenc; Marek Chmelík; Wolfgang Bogner; Martin Krššák; Siegfried Trattnig; Ladislav Valkovič
Journal:  NMR Biomed       Date:  2016-01       Impact factor: 4.044

8.  Interleaved multivoxel 31 P MR spectroscopy.

Authors:  Fabian Niess; Georg B Fiedler; Albrecht I Schmid; Sigrun Goluch; Roberta Kriegl; Michael Wolzt; Ewald Moser; Martin Meyerspeer
Journal:  Magn Reson Med       Date:  2016-02-23       Impact factor: 4.668

9.  Simple and effective exercise design for assessing in vivo mitochondrial function in clinical applications using (31)P magnetic resonance spectroscopy.

Authors:  Alison Sleigh; Victoria Lupson; Ajay Thankamony; David B Dunger; David B Savage; T Adrian Carpenter; Graham J Kemp
Journal:  Sci Rep       Date:  2016-01-11       Impact factor: 4.379

10.  Skeletal muscle alkaline Pi pool is decreased in overweight-to-obese sedentary subjects and relates to mitochondrial capacity and phosphodiester content.

Authors:  Ladislav Valkovič; Marek Chmelík; Barbara Ukropcová; Thomas Heckmann; Wolfgang Bogner; Ivan Frollo; Harald Tschan; Michael Krebs; Norbert Bachl; Jozef Ukropec; Siegfried Trattnig; Martin Krššák
Journal:  Sci Rep       Date:  2016-02-03       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.