Literature DB >> 25187036

Effect of deployment time on endotoxin and allergen exposure assessment using electrostatic dust collectors.

Brita Kilburg-Basnyat1, Nervana Metwali1, Peter S Thorne2.   

Abstract

The electrostatic dust collector (EDC) is a passive dust sampling device for exposure assessment of airborne endotoxin and possibly allergens. EDCs consist of a non-conducting plastic folder holding two or four electrostatic cloths of defined area. The sampling time needed to achieve detectable and reproducible loading for bioaerosols has not been systematically evaluated. Thus, in 15 Iowa farm homes EDCs were deployed for 7-, 14-, and 28-day sampling periods to determine if endotoxin and allergens could be quantified and if loading rates were uniform over time, i.e. if loads doubled from 7 to 14 days or 14 to 28 days and quadrupled from 7 to 28 days. Loadings between left and right paired EDC cloths were not significantly different and were highly correlated for endotoxin, total protein, and cat (Fel d1), dog (Can f1), and mouse (Mus m1) allergens (P < 0.001). EDCs performed especially well for endotoxin sampling with close agreement between paired samples (Pearson r = 0.96, P < 0.001). Endotoxin loading of the EDCs doubled from 7- to 14-day deployments as hypothesized although the loading rate decreased from 14 to 28 days of sampling with only a 1.38-fold increase. Allergen exposure assessment using EDCs was overall less satisfactory. Although there was reasonable agreement between paired samples, only exposures to cat, dog, and mouse allergens were reliable and these only at the longer deployment times.
© The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

Entities:  

Keywords:  allergens; asthma; bioaerosols; endotoxin; exposure assessment; house dust; passive sampling

Mesh:

Substances:

Year:  2014        PMID: 25187036      PMCID: PMC4303768          DOI: 10.1093/annhyg/meu063

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  29 in total

Review 1.  Bioaerosol health effects and exposure assessment: progress and prospects.

Authors:  J Douwes; P Thorne; N Pearce; D Heederik
Journal:  Ann Occup Hyg       Date:  2003-04

Review 2.  Organic dust toxic syndrome: an acute febrile reaction to organic dust exposure distinct from hypersensitivity pneumonitis.

Authors:  S Von Essen; R A Robbins; A B Thompson; S I Rennard
Journal:  J Toxicol Clin Toxicol       Date:  1990

3.  Endotoxin levels in settled airborne dust in European schools: the HITEA school study.

Authors:  J H Jacobs; E J M Krop; A Borras-Santos; J-P Zock; M Taubel; A Hyvarinnen; J Pekkanen; G Doekes; D J J Heederik
Journal:  Indoor Air       Date:  2013-09-23       Impact factor: 5.770

4.  Sampling, extraction and measurement of bacteria, endotoxin, fungi and inflammatory potential of settling indoor dust.

Authors:  Anne Mette Madsen; Christoffer B Matthiesen; Margit W Frederiksen; Marie Frederiksen; Mika Frankel; Michal Spilak; Lars Gunnarsen; Michael Timm
Journal:  J Environ Monit       Date:  2012-11-15

5.  Endotoxin levels in homes and classrooms of Dutch school children and respiratory health.

Authors:  José H Jacobs; Esmeralda J M Krop; Siegfried de Wind; Jack Spithoven; Dick J J Heederik
Journal:  Eur Respir J       Date:  2012-10-25       Impact factor: 16.671

Review 6.  Endotoxin and lung injury.

Authors:  K L Brigham; B Meyrick
Journal:  Am Rev Respir Dis       Date:  1986-05

7.  Assessment of airborne exposures and health in flooded homes undergoing renovation.

Authors:  K A Hoppe; N Metwali; S S Perry; T Hart; P A Kostle; P S Thorne
Journal:  Indoor Air       Date:  2012-05-23       Impact factor: 5.770

8.  Mite faeces are a major source of house dust allergens.

Authors:  E R Tovey; M D Chapman; T A Platts-Mills
Journal:  Nature       Date:  1981-02-12       Impact factor: 49.962

9.  Predictors of airborne endotoxin in the home.

Authors:  J H Park; D L Spiegelman; D R Gold; H A Burge; D K Milton
Journal:  Environ Health Perspect       Date:  2001-08       Impact factor: 9.031

10.  Allergens and β-glucans in dutch homes and schools: characterizing airborne levels.

Authors:  Esmeralda J M Krop; José H Jacobs; Ingrid Sander; Monika Raulf-Heimsoth; Dick J J Heederik
Journal:  PLoS One       Date:  2014-02-14       Impact factor: 3.240

View more
  7 in total

Review 1.  Sampling Devices for Indoor Allergen Exposure: Pros and Cons.

Authors:  Torie Grant; Ana M Rule; Kirsten Koehler; Robert A Wood; Elizabeth C Matsui
Journal:  Curr Allergy Asthma Rep       Date:  2019-02-12       Impact factor: 4.806

2.  Electrostatic dust collectors compared to inhalable samplers for measuring endotoxin concentrations in farm homes.

Authors:  B Kilburg-Basnyat; T M Peters; S S Perry; P S Thorne
Journal:  Indoor Air       Date:  2015-09-21       Impact factor: 5.770

3.  The home air in agriculture pediatric intervention (HAPI) trial: Rationale and methods.

Authors:  Erin E Masterson; Lisa B Younglove; Adriana Perez; Elizabeth Torres; Jennifer E Krenz; Maria I Tchong French; Anne M Riederer; Paul D Sampson; Nervana Metwali; Esther Min; Karen L Jansen; Gino Aisenberg; Ryan S Babadi; Stephanie A Farquhar; Peter S Thorne; Catherine J Karr
Journal:  Contemp Clin Trials       Date:  2020-07-25       Impact factor: 2.226

4.  Bioaerosol Sampling: Classical Approaches, Advances, and Perspectives.

Authors:  Gediminas Mainelis
Journal:  Aerosol Sci Technol       Date:  2019-10-04       Impact factor: 4.809

5.  Performance of electrostatic dust collectors (EDCs) for endotoxin assessment in homes: Effect of mailing, placement, heating, and electrostatic charge.

Authors:  Brita Kilburg-Basnyat; Nervana Metwali; Peter S Thorne
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

6.  Lung function of primary cooks using LPG or biomass and the effect of particulate matter on airway epithelial barrier integrity.

Authors:  Emma M Stapleton; Abhilash Kizhakke Puliyakote; Nervana Metwali; Matthew Jeronimo; Ian M Thornell; Robert B Manges; Monalisa Bilas; Mohamed Ali Kamal Batcha; Mangaleswari Seeniappan Kumaravel; Kumar Durairaj; Kesavan Karuppusamy; Geetha Kathiresan; Sirajunnisa Abdul Rahim; Kumaran Shanmugam; Peter S Thorne; Thomas M Peters; Eric A Hoffman; Alejandro P Comellas
Journal:  Environ Res       Date:  2020-07-15       Impact factor: 6.498

7.  Effectiveness of portable HEPA air cleaners on reducing indoor endotoxin, PM10, and coarse particulate matter in an agricultural cohort of children with asthma: A randomized intervention trial.

Authors:  Anne M Riederer; Jennifer E Krenz; Maria I Tchong-French; Elizabeth Torres; Adriana Perez; Lisa R Younglove; Karen L Jansen; David C Hardie; Stephanie A Farquhar; Paul D Sampson; Nervana Metwali; Peter S Thorne; Catherine J Karr
Journal:  Indoor Air       Date:  2021-07-19       Impact factor: 5.770

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.