Abstract

Electrostatic Dust Collectors (EDCs) are in use for passive sampling of bioaerosols, but particular aspects of their performance have not yet been evaluated. This study investigated the effect of mailing EDCs on endotoxin loading and the effect of EDC deployment in front of, and away from, heated ventilation on endotoxin sampling. Endotoxin sampling efficiency of heated and unheated EDC cloths was also evaluated. Cross-country express mailing of dust-spiked EDCs yielded no significant changes in endotoxin concentrations compared to dust-only samples for both high-spiked EDCs (p = 0.30) and low-spiked EDCs (p = 0.36). EDCs were also deployed in 20 identical apartments with one EDC placed in front of the univent heater in each apartment and contemporaneous EDC placed on the built-in bookshelf in each apartment. The endotoxin concentrations were significantly different (p = 0.049) indicating that the placement of EDC does impact endotoxin sampling. Heated and unheated EDCs were deployed for 7 days in pairs in farm homes. There was a significant difference between endotoxin concentrations (p = 0.027) indicating that heating EDCs may diminish their electrostatic capabilities and impact endotoxin sampling. The last study investigated the electrostatic charge of 12 heated and 12 unheated EDC cloths. There was a significant difference in charge (p = 0.009) which suggests that heating EDC cloths may make them less effective for sampling. In conclusion, EDCs can be mailed to and from deployment sites, EDC placement in relationship to ventilation is crucial, and heating EDCs reduces their electrostatic charge which may diminish their endotoxin sampling capabilities.

Entities:  

Keywords:  Endotoxin; exposure assessment; house dust; passive sampling

Mesh:

Substances:

Year:  2016        PMID: 26325020      PMCID: PMC4766868          DOI: 10.1080/15459624.2015.1078468

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  19 in total

1.  Dust anchoring characteristics of electret fibres with respect to Der p 1 allergen carrying particles.

Authors:  P T Gaynor; J F Hughes
Journal:  Med Biol Eng Comput       Date:  1998-09       Impact factor: 2.602

2.  Comparison of sampling methods for the assessment of indoor microbial exposure.

Authors:  M Frankel; M Timm; E W Hansen; A M Madsen
Journal:  Indoor Air       Date:  2012-02-28       Impact factor: 5.770

3.  Allergen and endotoxin exposure in a companion animal hospital.

Authors:  Sadegh Samadi; Dick J J Heederik; Esmeralda J M Krop; Ali-Reza Jamshidifard; Ton Willemse; Inge M Wouters
Journal:  Occup Environ Med       Date:  2010-06-02       Impact factor: 4.402

4.  Surface sampling for endotoxin assessment using electrostatic wiping cloths.

Authors:  Peter S Thorne; Nervana Metwali; Ed Avol; Rob S McConnell
Journal:  Ann Occup Hyg       Date:  2005-02-02

5.  Sampling, extraction and measurement of bacteria, endotoxin, fungi and inflammatory potential of settling indoor dust.

Authors:  Anne Mette Madsen; Christoffer B Matthiesen; Margit W Frederiksen; Marie Frederiksen; Mika Frankel; Michal Spilak; Lars Gunnarsen; Michael Timm
Journal:  J Environ Monit       Date:  2012-11-15

6.  Electrostatic dust collectors compared to inhalable samplers for measuring endotoxin concentrations in farm homes.

Authors:  B Kilburg-Basnyat; T M Peters; S S Perry; P S Thorne
Journal:  Indoor Air       Date:  2015-09-21       Impact factor: 5.770

7.  Effect of deployment time on endotoxin and allergen exposure assessment using electrostatic dust collectors.

Authors:  Brita Kilburg-Basnyat; Nervana Metwali; Peter S Thorne
Journal:  Ann Occup Hyg       Date:  2014-09-03

8.  Assessment of airborne exposure to endotoxin and pyrogenic active dust using electrostatic dustfall collectors (EDCs).

Authors:  Verena Liebers; Vera van Kampen; Jürgen Bünger; Maria Düser; Heike Stubel; Thomas Brüning; Monika Raulf-Heimsoth
Journal:  J Toxicol Environ Health A       Date:  2012

9.  Human alveolar macrophage responses to air pollution particulates are associated with insoluble components of coarse material, including particulate endotoxin.

Authors:  J M Soukup; S Becker
Journal:  Toxicol Appl Pharmacol       Date:  2001-02-15       Impact factor: 4.219

10.  The dustfall collector--a simple passive tool for long-term collection of airborne dust: a project under the Danish Mould in Buildings program (DAMIB).

Authors:  H Würtz; T Sigsgaard; O Valbjørn; G Doekes; H W Meyer
Journal:  Indoor Air       Date:  2005       Impact factor: 5.770

View more
  9 in total

1.  Electrostatic dust collectors compared to inhalable samplers for measuring endotoxin concentrations in farm homes.

Authors:  B Kilburg-Basnyat; T M Peters; S S Perry; P S Thorne
Journal:  Indoor Air       Date:  2015-09-21       Impact factor: 5.770

2.  The home air in agriculture pediatric intervention (HAPI) trial: Rationale and methods.

Authors:  Erin E Masterson; Lisa B Younglove; Adriana Perez; Elizabeth Torres; Jennifer E Krenz; Maria I Tchong French; Anne M Riederer; Paul D Sampson; Nervana Metwali; Esther Min; Karen L Jansen; Gino Aisenberg; Ryan S Babadi; Stephanie A Farquhar; Peter S Thorne; Catherine J Karr
Journal:  Contemp Clin Trials       Date:  2020-07-25       Impact factor: 2.226

3.  Bioaerosol Sampling: Classical Approaches, Advances, and Perspectives.

Authors:  Gediminas Mainelis
Journal:  Aerosol Sci Technol       Date:  2019-10-04       Impact factor: 4.809

4.  Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR.

Authors:  Jennie Cox; Reshmi Indugula; Stephen Vesper; Zheng Zhu; Roman Jandarov; Tiina Reponen
Journal:  Environ Sci Process Impacts       Date:  2017-10-18       Impact factor: 4.238

5.  Lung function of primary cooks using LPG or biomass and the effect of particulate matter on airway epithelial barrier integrity.

Authors:  Emma M Stapleton; Abhilash Kizhakke Puliyakote; Nervana Metwali; Matthew Jeronimo; Ian M Thornell; Robert B Manges; Monalisa Bilas; Mohamed Ali Kamal Batcha; Mangaleswari Seeniappan Kumaravel; Kumar Durairaj; Kesavan Karuppusamy; Geetha Kathiresan; Sirajunnisa Abdul Rahim; Kumaran Shanmugam; Peter S Thorne; Thomas M Peters; Eric A Hoffman; Alejandro P Comellas
Journal:  Environ Res       Date:  2020-07-15       Impact factor: 6.498

6.  Effectiveness of portable HEPA air cleaners on reducing indoor endotoxin, PM10, and coarse particulate matter in an agricultural cohort of children with asthma: A randomized intervention trial.

Authors:  Anne M Riederer; Jennifer E Krenz; Maria I Tchong-French; Elizabeth Torres; Adriana Perez; Lisa R Younglove; Karen L Jansen; David C Hardie; Stephanie A Farquhar; Paul D Sampson; Nervana Metwali; Peter S Thorne; Catherine J Karr
Journal:  Indoor Air       Date:  2021-07-19       Impact factor: 5.770

7.  Pig Farmers' Homes Harbor More Diverse Airborne Bacterial Communities Than Pig Stables or Suburban Homes.

Authors:  Ditte V Vestergaard; Gitte J Holst; Ioannis Basinas; Grethe Elholm; Vivi Schlünssen; Allan Linneberg; Tina Šantl-Temkiv; Kai Finster; Torben Sigsgaard; Ian P G Marshall
Journal:  Front Microbiol       Date:  2018-05-01       Impact factor: 5.640

8.  Home Assessment of Indoor Microbiome (HAIM) in Relation to Lower Respiratory Tract Infections among Under-Five Children in Ibadan, Nigeria: The Study Protocol.

Authors:  Adekunle G Fakunle; Babatunde Olusola; Nkosana Jafta; Adedayo Faneye; Dick Heederik; Lidwien A M Smit; Rajen N Naidoo
Journal:  Int J Environ Res Public Health       Date:  2020-03-13       Impact factor: 3.390

Review 9.  Electrostatic Dust Cloth: A Useful Passive Sampling Method When Assessing Exposure to Fungi Demonstrated in Studies Developed in Portugal (2018-2021).

Authors:  Carla Viegas; Marta Dias; Susana Viegas
Journal:  Pathogens       Date:  2022-03-12
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.