Literature DB >> 25159301

Bivariate optimization of orthodontic mini-implant thread height and pitch.

Shuning Shen1, Yingying Sun, Chen Zhang, Yongjin Yang, Zhiren Li, Xingwei Cai, Yinzhong Duan, Tao Li.   

Abstract

PURPOSE: Mini-implants have been used as anchorage for years, but failure is common in clinical practice. Mini-implant design is a critical factor affecting its stability. The aim of this study was to evaluate the effect of continuous and simultaneous variations of thread height and pitch on the biomechanical properties of an orthodontic mini-implant.
METHOD: A 3D finite element model, composed of a posterior maxilla section and an orthodontic mini-implant, was created. Mini-implant thread height ranged from 0.10 to 0.40 mm, and thread pitch ranged from 0.50 to 2.00 mm. Effects of the implant thread height and pitch on the maximum Von Mises stresses in maxilla and mini-implant, as well as maximum displacements in the mini-implant, were evaluated by a finite element method. Bivariate analysis was used to determine the optimal range of thread height and pitch.
RESULTS: Variation of thread height and pitch decreased the maximum Von Mises stresses in cortical bone, cancellous bone and mini-implant by 54.9, 78.4 and 23.6 %, respectively. The maximum displacement in the mini-implant decreased by 21.8 %.
CONCLUSION: Maxillary stress and mini-implant stability were influenced by mini-implant thread height and pitch. Increased thread height with a thread pitch of 1.20 mm was better for orthodontic mini-implant in the maxillary posterior region. Thread height played a more significant role than the thread pitch in reducing maxillary stress and enhancing orthodontic mini-implant stability.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25159301     DOI: 10.1007/s11548-014-1107-8

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  24 in total

1.  Effects of thread depth, taper shape, and taper length on the mechanical properties of mini-implants.

Authors:  Jenny Zwei-Chieng Chang; Yi-Jane Chen; Yuan-Yi Tung; Yu-Ying Chiang; Eddie Hsiang-Hua Lai; Weng-Pin Chen; Chun-Pin Lin
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-03       Impact factor: 2.650

2.  Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis.

Authors:  Mitsuru Motoyoshi; Shinya Yano; Takashi Tsuruoka; Noriyoshi Shimizu
Journal:  Clin Oral Implants Res       Date:  2005-08       Impact factor: 5.977

3.  Immediate load protocol for anterior maxilla with cortical bone from mandibular ramus.

Authors:  Cameron Y S Lee
Journal:  Implant Dent       Date:  2006-06       Impact factor: 2.454

4.  Osseointegration of miniscrews: a histomorphometric evaluation.

Authors:  Bart Vande Vannet; Mehran Moradi Sabzevar; Heinrich Wehrbein; Karlien Asscherickx
Journal:  Eur J Orthod       Date:  2007-10       Impact factor: 3.075

5.  A simplified technique of maxillomandibular fixation.

Authors:  G Arthur; N Berardo
Journal:  J Oral Maxillofac Surg       Date:  1989-11       Impact factor: 1.895

6.  Geometric comparison of five interchangeable implant prosthetic retaining screws.

Authors:  M J Jaarda; M E Razzoog; D G Gratton
Journal:  J Prosthet Dent       Date:  1995-10       Impact factor: 3.426

7.  Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor.

Authors:  Omer Lutfi Koca; Gurcan Eskitascioglu; Aslihan Usumez
Journal:  J Prosthet Dent       Date:  2005-01       Impact factor: 3.426

Review 8.  Miniscrews in orthodontic treatment: review and analysis of published clinical trials.

Authors:  Adriano G Crismani; Michael H Bertl; Ales G Celar; Hans-Peter Bantleon; Charles J Burstone
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-01       Impact factor: 2.650

9.  Histomorphologic and histomophometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage.

Authors:  José Nilo O Freire; Nelson R F A Silva; José N Gil; Ricardo S Magini; Paulo G Coelho
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-06       Impact factor: 2.650

Review 10.  Systematic review of mini-implant displacement under orthodontic loading.

Authors:  Manuel Nienkemper; Jörg Handschel; Dieter Drescher
Journal:  Int J Oral Sci       Date:  2013-12-20       Impact factor: 6.344

View more
  2 in total

1.  Optimization Analysis of Two-Factor Continuous Variable between Thread Depth and Pitch of Microimplant under Toque Force.

Authors:  Yushan Ye; Jiuyang Jiao; Song Fan; Jieying He; Yamei Wang; Qinghe Yao; Wei Wang; Jinsong Li; Shaohai Chang
Journal:  Comput Math Methods Med       Date:  2022-06-20       Impact factor: 2.809

2.  Three-dimensional optimization and sensitivity analysis of dental implant thread parameters using finite element analysis.

Authors:  Maryam Geramizadeh; Hamidreza Katoozian; Reza Amid; Mahdi Kadkhodazadeh
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2018-04-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.