Histomorphologic and histomophometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage.

José Nilo O Freire1, Nelson R F A Silva, José N Gil, Ricardo S Magini, Paulo G Coelho.   

Abstract

INTRODUCTION: The purpose of this study was to evaluate the bone response to statically loaded 2.5-mm diameter mini-implants of 6 and 10 mm lengths activated after various healing periods in a dog model.
METHODS: Seventy-eight machined-surface Ti-6Al-4V mini-implants were bilaterally placed in the mandibular premolar and molar regions of 6 beagle dogs. The left (experimental) and the right (control) hemi-arches received 6 and 7 mini-implants, respectively. Experimental mini-implants healing periods of 0 days (immediately activated), 1 week, and 3 weeks were followed by a 12-week load activation period (250 g between parallel implant pairs). Control (nonloaded) mini-implant groups were placed for 12 weeks, 3 weeks, and 1 week before the dogs were killed they provided data concerning the experimental groups' bone to mini-implant scenarios at load activation times. The mandibles were exposed by sharp dissection, and decalcified specimens were prepared for histomorphologic and histomorphometric (bone to mini-implant contact) assessment.
RESULTS: Survival rates were 100% and 77.78% for the control and the experimental groups, respectively. Survival rates were 88.89% for the 10-mm and 66.67% for the 6-mm experimental groups. All failed devices had tissue inflammation and were lost after spring placement. The control groups showed classic bone-healing events, and the experimental groups showed mature bone morphology after 12 weeks in vivo regardless of placement time before load activation. Bone to implant contact values were not significantly different between the experimental and the control groups that remained 12 weeks in vivo.
CONCLUSIONS: These results showed that low-intensity immediate or early orthodontic static loads did not affect mini-implant performance.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17561041     DOI: 10.1016/j.ajodo.2006.09.040

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  10 in total

1.  Biocompatibility of bioabsorbable Mg-Ca alloys with rare earth elements addition.

Authors:  Daniel Fernandes; Celso Resende; Jacqueline Cavalcanti; Dexue Liu; Carlos Elias
Journal:  J Mater Sci Mater Med       Date:  2019-12-03       Impact factor: 3.896

2.  Bivariate optimization of orthodontic mini-implant thread height and pitch.

Authors:  Shuning Shen; Yingying Sun; Chen Zhang; Yongjin Yang; Zhiren Li; Xingwei Cai; Yinzhong Duan; Tao Li
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-08-27       Impact factor: 2.924

3.  Fracture strength of orthodontic mini-implants.

Authors:  Tatiana Feres Assad-Loss; Flávia Mitiko Fernandes Kitahara-Céia; Giordani Santos Silveira; Carlos Nelson Elias; José Nelson Mucha
Journal:  Dental Press J Orthod       Date:  2017 May-Jun

4.  In vitro study of the orthodontic mini-implants influence on the growth of human osteoblasts.

Authors:  Andreea Moldoveanu; Mihnea Ioan Nicolescu; Mirela Veronica Bucur; George Gabriel Moldoveanu; Cristian Funieru; Ionela Victoria Neagoe; Gina Manda; Tamara Rahela Ioana; Lucian Toma Ciocan
Journal:  Rom J Morphol Embryol       Date:  2021 Jul-Sep       Impact factor: 0.833

5.  Ultrastructure of the interface between periodontal tissues and titanium mini-implants.

Authors:  Jaqueline Carvalho Rinaldi; Victor E Arana-Chavez
Journal:  Angle Orthod       Date:  2010-05       Impact factor: 2.079

6.  Effects of immediate orthodontic and orthopedic forces on peri-miniscrew bones: histomorphologic and histomorphometric assessment in dogs.

Authors:  Mansour Rismanchian; Sayed Hamid Raji; Danesh Teimori Rik; Sayed Mohammad Razavi; Navid Khalighinejad; Hossein Goroohi; Hamid Badrian
Journal:  Int J Dent       Date:  2012-12-25

7.  A study of interleukin 1β levels in peri-miniscrew crevicular fluid (PMCF).

Authors:  Nitika Monga; Sushma Chaurasia; Om Prakash Kharbanda; Ritu Duggal; Moganty Raja Rajeswari
Journal:  Prog Orthod       Date:  2014-04-01       Impact factor: 2.750

8.  Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

Authors:  Barat Ali Ramazanzadeh; Kazem Fatemi; Mahboobe Dehghani; Nooshin Mohtasham; Arezoo Jahanbin; Hamed Sadeghian
Journal:  ISRN Dent       Date:  2014-04-06

9.  Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity.

Authors:  Hyun-Ju Oh; Jung-Yul Cha; Hyung-Seog Yu; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2018-08-08       Impact factor: 1.372

10.  Bone remodelling patterns around orthodontic mini-implants migrating in bone: an experimental study in rat vertebrae.

Authors:  Kathrin Becker; Nicole Rauch; Giulia Brunello; Sarah Azimi; Mathias Beller; Mira Hüfner; Manuel Nienkemper; Beryl Schwarz-Herzke; Dieter Drescher
Journal:  Eur J Orthod       Date:  2021-12-01       Impact factor: 3.075

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.