Literature DB >> 8531155

Geometric comparison of five interchangeable implant prosthetic retaining screws.

M J Jaarda1, M E Razzoog, D G Gratton.   

Abstract

Eight geometric parameters of five interchangeable prosthetic retaining screws (#1-3i Implant Innovation-gold, #2-Impla-Med-gold, #3-Nobelpharma-gold, #4-3i Implant Innovation-titanium, and #5-Implant Support Systems-titanium) were recorded with an Amray 1000-B scanning electron microscope at x20 to x200 magnification. Five screws of each type were measured and eight parameters were evaluated: (A) diameter of head, (B) screw length, (C) thread pitch, (D) major diameter, (E) neck diameter (F) length of neck, (G) crest width, and (H) root width. The Nobelpharma-gold prosthetic retaining screws served as controls. The results revealed significant differences between the control and test screws in all parameters except parameters C and G (ANOVA, p < 0.05) and Duncan's multiple range test (significance level 0.05). On the basis of these differences, it was concluded that interchanging prosthetic retaining screws can introduce unknown variables in treating patients.

Entities:  

Mesh:

Year:  1995        PMID: 8531155     DOI: 10.1016/s0022-3913(05)80377-4

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

1.  Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.

Authors:  Seok-Gyu Kim; Chae-Heon Chung; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

2.  In Vitro Study of Preload Loss in Different Implant Abutment Connection Designs.

Authors:  Ana Sofia Vinhas; Carlos Aroso; Filomena Salazar; Marta Relvas; Ana Cristina Braga; Blanca Ríos-Carrasco; Javier Gil; José Vicente Rios-Santos; Ana Fernández-Palacín; Mariano Herrero-Climent
Journal:  Materials (Basel)       Date:  2022-02-14       Impact factor: 3.623

3.  Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

Authors:  Atais Bacchi; Alexandre Regalin; Claudia Lopes Brilhante Bhering; Rodrigo Alessandretti; Aloisio Oro Spazzin
Journal:  J Adv Prosthodont       Date:  2015-10-28       Impact factor: 1.904

4.  Bivariate optimization of orthodontic mini-implant thread height and pitch.

Authors:  Shuning Shen; Yingying Sun; Chen Zhang; Yongjin Yang; Zhiren Li; Xingwei Cai; Yinzhong Duan; Tao Li
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-08-27       Impact factor: 2.924

5.  A Performance Comparison between Automated Deep Learning and Dental Professionals in Classification of Dental Implant Systems from Dental Imaging: A Multi-Center Study.

Authors:  Jae-Hong Lee; Young-Taek Kim; Jong-Bin Lee; Seong-Nyum Jeong
Journal:  Diagnostics (Basel)       Date:  2020-11-07

Review 6.  Review of the Mechanical Behavior of Different Implant-Abutment Connections.

Authors:  Ana Sofia Vinhas; Carlos Aroso; Filomena Salazar; Paula López-Jarana; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2020-11-23       Impact factor: 3.390

7.  Deep learning improves implant classification by dental professionals: a multi-center evaluation of accuracy and efficiency.

Authors:  Jae-Hong Lee; Young-Taek Kim; Jong-Bin Lee; Seong-Nyum Jeong
Journal:  J Periodontal Implant Sci       Date:  2022-06       Impact factor: 2.086

8.  Transfer Learning via Deep Neural Networks for Implant Fixture System Classification Using Periapical Radiographs.

Authors:  Jong-Eun Kim; Na-Eun Nam; June-Sung Shim; Yun-Hoa Jung; Bong-Hae Cho; Jae Joon Hwang
Journal:  J Clin Med       Date:  2020-04-14       Impact factor: 4.241

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.