Resolution of hemolysis from pump thrombus during left ventricular assist device exchange.

Shinya Unai1, Hitoshi Hirose2, John W Entwistle1, Louis E Samuels1.   

Abstract

A 50-year-old male who underwent a HeartMate II left ventricular assist device placement for ischemic cardiomyopathy presented with discolored urine and hemolysis 3 mo after the operation. His hemolysis was thought to be due to thrombosis within the pump. Imaging studies were not able to visualize a left ventricular thrombus. Medical management with anticoagulation failed and he underwent surgery for a pump exchange. Intraoperatively, a firm thrombus was found within the pump of the HeartMate II, and the color of the urine changed dramatically from cola-colored to yellow which enabled us to confirm the diagnosis.

Entities:  

Keywords:  Cardiac surgery; Hemolysis; Left ventricular assist device; Thrombosis

Year:  2014        PMID: 25133150      PMCID: PMC4133429          DOI: 10.12998/wjcc.v2.i8.373

Source DB:  PubMed          Journal:  World J Clin Cases        ISSN: 2307-8960            Impact factor:   1.337


  10 in total

1.  Thrombus formation in a HeartMate II left ventricular assist device.

Authors:  Anna Lassia Meyer; Christian Kuehn; Jürgen Weidemann; Doris Malehsa; Christoph Bara; Stefan Fischer; Axel Haverich; Martin Strüber
Journal:  J Thorac Cardiovasc Surg       Date:  2008-01       Impact factor: 5.209

Review 2.  What is the optimal anticoagulation in patients with a left ventricular assist device?

Authors:  Michele Rossi; Giuseppe Filiberto Serraino; Federica Jiritano; Attilio Renzulli
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-07-03

3.  Unexpected abrupt increase in left ventricular assist device thrombosis.

Authors:  Randall C Starling; Nader Moazami; Scott C Silvestry; Gregory Ewald; Joseph G Rogers; Carmelo A Milano; J Eduardo Rame; Michael A Acker; Eugene H Blackstone; John Ehrlinger; Lucy Thuita; Maria M Mountis; Edward G Soltesz; Bruce W Lytle; Nicholas G Smedira
Journal:  N Engl J Med       Date:  2013-11-27       Impact factor: 91.245

4.  Early thrombus in a HeartMate II left ventricular assist device: a potential cause of hemolysis and diagnostic dilemma.

Authors:  Castigliano M Bhamidipati; Gorav Ailawadi; James Bergin; John A Kern
Journal:  J Thorac Cardiovasc Surg       Date:  2009-11-27       Impact factor: 5.209

5.  Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: analysis of outpatient anti-coagulation.

Authors:  Andrew J Boyle; Stuart D Russell; Jeffrey J Teuteberg; Mark S Slaughter; Nader Moazami; Francis D Pagani; O Howard Frazier; Gerald Heatley; David J Farrar; Ranjit John
Journal:  J Heart Lung Transplant       Date:  2009-09       Impact factor: 10.247

6.  Development of a novel echocardiography ramp test for speed optimization and diagnosis of device thrombosis in continuous-flow left ventricular assist devices: the Columbia ramp study.

Authors:  Nir Uriel; Kerry A Morrison; Arthur R Garan; Tomoko S Kato; Melana Yuzefpolskaya; Farhana Latif; Susan W Restaino; Donna M Mancini; Margaret Flannery; Hiroo Takayama; Ranjit John; Paolo C Colombo; Yoshifumi Naka; Ulrich P Jorde
Journal:  J Am Coll Cardiol       Date:  2012-10-03       Impact factor: 24.094

7.  Readmissions after implantation of axial flow left ventricular assist device.

Authors:  Tal Hasin; Yariv Marmor; Walter Kremers; Yan Topilsky; Cathy J Severson; John A Schirger; Barry A Boilson; Alfredo L Clavell; Richard J Rodeheffer; Robert P Frantz; Brooks S Edwards; Naveen L Pereira; John M Stulak; Lyle Joyce; Richard Daly; Soon J Park; Sudhir S Kushwaha
Journal:  J Am Coll Cardiol       Date:  2012-12-05       Impact factor: 24.094

8.  Continuous-flow left ventricular assist device exchange: clinical outcomes.

Authors:  Takeyoshi Ota; Halit Yerebakan; Hirokazu Akashi; Hiroo Takayama; Nir Uriel; Paolo C Colombo; Urich P Jorde; Yoshifumi Naka
Journal:  J Heart Lung Transplant       Date:  2013-08-09       Impact factor: 10.247

9.  Pump replacement for left ventricular assist device failure can be done safely and is associated with low mortality.

Authors:  Nader Moazami; Carmelo A Milano; Ranjit John; Benjamin Sun; Robert M Adamson; Francis D Pagani; Nicholas Smedira; Mark S Slaughter; David J Farrar; O Howard Frazier
Journal:  Ann Thorac Surg       Date:  2012-12-20       Impact factor: 4.330

10.  Low thromboembolic risk for patients with the Heartmate II left ventricular assist device.

Authors:  Ranjit John; Forum Kamdar; Kenneth Liao; Monica Colvin-Adams; Leslie Miller; Lyle Joyce; Andrew Boyle
Journal:  J Thorac Cardiovasc Surg       Date:  2008-09-14       Impact factor: 5.209

  10 in total
  1 in total

1.  Ventricular Assist Device Implantation Configurations Impact Overall Mechanical Circulatory Support System Thrombogenic Potential.

Authors:  Wei-Che Chiu; Yared Alemu; Allison J McLarty; Shmuel Einav; Marvin J Slepian; Danny Bluestein
Journal:  ASAIO J       Date:  2017 May/Jun       Impact factor: 2.872

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.