Literature DB >> 30501001

Metal wear particles in hematopoietic marrow of the axial skeleton in patients with prior revision for mechanical failure of a hip or knee arthroplasty.

Deborah J Hall1, Robin Pourzal1, Joshua J Jacobs1, Robert M Urban1.   

Abstract

Wear particles generated by hip and knee arthroplasties disseminate to the liver and spleen with the highest concentrations observed in subjects who have had a failed arthroplasty. We asked to what extent metallic particles could also disseminate to remote hematopoietic bone marrow. Cored samples of red marrow from the axial skeleton and proximal humerus were obtained postmortem from four males and two females aged 79-92 years. Seven to seventeen years prior to their demise, each subject had undergone successful revision of their arthroplasty for mechanical failure in which an unintended wear condition had generated a large volume of metal particles. The marrow samples were analyzed using stained histological sections and energy dispersive X-ray analysis. Intracellular metal alloy particles were detected in the bone marrow of the cranium, proximal humerus, sternum, ribs, lumbar vertebrae, and the iliac crest. The components previously revised for mechanical failure were confirmed to be the predominant source of the disseminated wear debris. Particles of either Ti, Ti6Al4V, CoCrMo, FeCrNi alloys, or BaSO4 were identified in 24 of the 25 marrow samples examined. The particles ranged in size from 50 nm (the limit of resolution of our technique) to 6 μm. Metallic wear particles generated by hip and knee arthroplasties can disseminate widely to hematopoietic bone marrow throughout the axial skeleton and proximal humerus, especially in cases with a history of severe wear. The hematopoietic microenvironment is potentially sensitive to metallic degradation products. However, actual medical sequelae from disseminated wear debris is a rare occurrence.
© 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1930-1936, 2019. © 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  bone marrow; failed implant; joint arthroplasty; nanometer wear particles; systemic dissemination

Mesh:

Substances:

Year:  2018        PMID: 30501001      PMCID: PMC6542727          DOI: 10.1002/jbm.b.34285

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  25 in total

1.  Systemic distribution of wear debris after hip replacement. A cause for concern?

Authors:  V G Langkamer; C P Case; P Heap; A Taylor; C Collins; M Pearse; L Solomon
Journal:  J Bone Joint Surg Br       Date:  1992-11

2.  Reactions of the articular capsule to wear products of artificial joint prostheses.

Authors:  H G Willert; M Semlitsch
Journal:  J Biomed Mater Res       Date:  1977-03

3.  Evidence for Kupffer cell migration along liver sinusoids, from high-resolution in vivo microscopy.

Authors:  P J MacPhee; E E Schmidt; A C Groom
Journal:  Am J Physiol       Date:  1992-07

Review 4.  Wear particles.

Authors:  Joshua J Jacobs; Nadim J Hallab; Robert M Urban; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2006-04       Impact factor: 5.284

5.  The lexicon of polyethylene wear in artificial joints.

Authors:  Harry A McKellop
Journal:  Biomaterials       Date:  2007-08-16       Impact factor: 12.479

Review 6.  Cobalt metabolism and toxicology--a brief update.

Authors:  Lars Ole Simonsen; Henrik Harbak; Poul Bennekou
Journal:  Sci Total Environ       Date:  2012-06-23       Impact factor: 7.963

7.  Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement.

Authors:  R M Urban; J J Jacobs; M J Tomlinson; J Gavrilovic; J Black; M Peoc'h
Journal:  J Bone Joint Surg Am       Date:  2000-04       Impact factor: 5.284

8.  Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty.

Authors:  Robert M Urban; Michael J Tomlinson; Deborah J Hall; Joshua J Jacobs
Journal:  J Arthroplasty       Date:  2004-12       Impact factor: 4.757

Review 9.  Nanotoxicology of metal wear particles in total joint arthroplasty: a review of current concepts.

Authors:  Fabrizio Billi; Pat Campbell
Journal:  J Appl Biomater Biomech       Date:  2010 Jan-Apr

10.  Titanium transport through the blood stream. An experimental study on rats.

Authors:  Daniel G Olmedo; Débora Tasat; María B Guglielmotti; Rómulo L Cabrini
Journal:  J Mater Sci Mater Med       Date:  2003-12       Impact factor: 3.896

View more
  2 in total

1.  Investigation of Cytotoxicity, Oxidative Stress, and Inflammatory Responses of Tantalum Nanoparticles in THP-1-Derived Macrophages.

Authors:  Li Zhang; El-Mustapha Haddouti; Hannes Beckert; Ralf Biehl; Shyam Pariyar; Julian M Rüwald; Xian Li; Max Jaenisch; Christof Burger; Dieter C Wirtz; Koroush Kabir; Frank A Schildberg
Journal:  Mediators Inflamm       Date:  2020-12-03       Impact factor: 4.711

Review 2.  The contribution of the histopathological examination to the diagnosis of adverse local tissue reactions in arthroplasty.

Authors:  Giorgio Perino; Ivan De Martino; Lingxin Zhang; Zhidao Xia; Jiri Gallo; Shonali Natu; David Langton; Monika Huber; Anastasia Rakow; Janosch Schoon; Enrique Gomez-Barrena; Veit Krenn
Journal:  EFORT Open Rev       Date:  2021-06-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.