Reliability and validity of two versions of the upper extremity functional index.

Bert M Chesworth1, Clayon B Hamilton2, David M Walton3, Melissa Benoit3, Tracy A Blake3, Heather Bredy3, Cameron Burns3, Lianne Chan3, Elizabeth Frey3, Graham Gillies3, Teresa Gravelle3, Rick Ho3, Robert Holmes3, Roland L J Lavallée3, Melanie MacKinnon3, Alishah Jamal Merchant3, Tammy Sherman3, Kelly Spears3, Darryl Yardley3.   

Abstract

PURPOSE: To examine the reliability, validity, and sensitivity to change of the 20-item version and the Rasch-refined 15-item version of the Upper Extremity Functional Index (UEFI-20 and UEFI-15, respectively) and to determine the impact of arm dominance on the positive minimal clinically important difference (pMCID).
METHODS: Adults with upper-extremity (UE) dysfunction completed the UEFI-20, Upper Extremity Functional Scale (UEFS), Pain Limitation Scale, and Pain Intensity Scale at their initial physiotherapy assessment (Time 1); 24-48 hours later (Time 2); and 3 weeks into treatment or at discharge, whichever came first (Time 3). Demographics, including working status, were obtained at Time 1. Global ratings of change (GRC) were provided by the treating physiotherapist and patient at Time 3. The UEFI-15 was calculated from relevant items in the UEFI-20. The intra-class correlation coefficient (ICC) and minimal detectable change (MDC) quantified test-retest reliability (Time 1-Time 2). Cross-sectional convergent validity was determined by the association (Pearson's r) between Time 1 measures of function and pain. Known-groups validity was evaluated with a one-way ANOVA across three levels of working status. Longitudinal validity was determined by the association (Pearson's r) between function and pain change scores (Time 1-Time 3). Receiver operating characteristic (ROC) curves estimated the pMCID using Time 1-Time 3 change scores and average patient/therapist GRC.
RESULTS: Reliability for the UEFI-20 and UEFI-15 was the same (ICC=0.94 for both measures). MDC values were 9.4/80 for the UEFI-20 and 8.8/100 for the UEFI-15. Cross-sectional, known-groups, and longitudinal validity were confirmed for both UEFI measures. pMCID values were 8/80 for the UEFI-20 and 6.7/100 for the UEFI-15; pMCID was higher for people whose non-dominant arm was affected.
CONCLUSIONS: Both UEFI measures show acceptable reliability and validity. Arm dominance affects pMCID. The UEFI-15 is recommended because it measures only one dimension: UE function.

Entities:  

Keywords:  ROC curve; outcome assessment; physiology; reproducibility of results; upper limb

Year:  2014        PMID: 25125777      PMCID: PMC4130402          DOI: 10.3138/ptc.2013-45

Source DB:  PubMed          Journal:  Physiother Can        ISSN: 0300-0508            Impact factor:   1.037


  24 in total

Review 1.  Applying the right statistics: analyses of measurement studies.

Authors:  J M Bland; D G Altman
Journal:  Ultrasound Obstet Gynecol       Date:  2003-07       Impact factor: 7.299

2.  A comparison of the ability of two upper extremity assessments to measure change in function.

Authors:  Leigh A Lehman; Bhagwant S Sindhu; Orit Shechtman; Sergio Romero; Craig A Velozo
Journal:  J Hand Ther       Date:  2009-11-26       Impact factor: 1.950

3.  The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection.

Authors:  J E Ware; C D Sherbourne
Journal:  Med Care       Date:  1992-06       Impact factor: 2.983

4.  Measuring functional outcomes in work-related upper extremity disorders. Development and validation of the Upper Extremity Function Scale.

Authors:  G Pransky; M Feuerstein; J Himmelstein; J N Katz; M Vickers-Lahti
Journal:  J Occup Environ Med       Date:  1997-12       Impact factor: 2.162

5.  Convergent validity of the constant-murley outcome measure in patients with rotator cuff disease.

Authors:  Helen Razmjou; Andrea Bean; Joy C Macdermid; Varda van Osnabrugge; Niki Travers; Richard Holtby
Journal:  Physiother Can       Date:  2008-04-15       Impact factor: 1.037

6.  The meaning and use of the area under a receiver operating characteristic (ROC) curve.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

7.  When minimal detectable change exceeds a diagnostic test-based threshold change value for an outcome measure: resolving the conflict.

Authors:  Paul W Stratford; Daniel L Riddle
Journal:  Phys Ther       Date:  2012-07-05

8.  Minimal clinically important differences in ASES and simple shoulder test scores after nonoperative treatment of rotator cuff disease.

Authors:  Robert Z Tashjian; Julia Deloach; Andrew Green; Christina A Porucznik; Amy P Powell
Journal:  J Bone Joint Surg Am       Date:  2010-02       Impact factor: 5.284

9.  The patient-specific functional scale: validity, reliability, and responsiveness in patients with upper extremity musculoskeletal problems.

Authors:  Cheryl Hefford; J Haxby Abbott; Richard Arnold; G David Baxter
Journal:  J Orthop Sports Phys Ther       Date:  2012-02-01       Impact factor: 4.751

10.  Cross-sectional and longitudinal construct validity of two rotator cuff disease-specific outcome measures.

Authors:  Helen Razmjou; Andrea Bean; Varda van Osnabrugge; Joy C MacDermid; Richard Holtby
Journal:  BMC Musculoskelet Disord       Date:  2006-03-13       Impact factor: 2.362

View more
  14 in total

1.  Feasibility of integrative games and novel therapeutic game controller for telerehabilitation of individuals chronic post-stroke living in the community.

Authors:  Grigore C Burdea; Namrata Grampurohit; Nam Kim; Kevin Polistico; Ashwin Kadaru; Simcha Pollack; Mooyeon Oh-Park; A M Barrett; Emma Kaplan; Jenny Masmela; Phalgun Nori
Journal:  Top Stroke Rehabil       Date:  2019-12-25       Impact factor: 2.119

2.  Patient-Reported Outcome Measures in Sports Medicine: A Concise Resource for Clinicians and Researchers.

Authors:  Kenneth C Lam; Ashley N Marshall; Alison R Snyder Valier
Journal:  J Athl Train       Date:  2020-02-07       Impact factor: 2.860

3.  A feasibility study to determine the benefits of upper extremity virtual rehabilitation therapy for coping with chronic pain post-cancer surgery.

Authors:  Gregory House; Grigore Burdea; Namrata Grampurohit; Kevin Polistico; Doru Roll; Frank Damiani; Jasdeep Hundal; Didier Demesmin
Journal:  Br J Pain       Date:  2016-08-24

4.  Does subscapularis integrity influence outcome following latissimus dorsi tendon transfer for irreparable cuff tears? A comparative series of 48 patients.

Authors:  James G Cunningham; Jay R Ebert; Peter Campbell; Travis Falconer
Journal:  J Orthop       Date:  2022-05-04

Review 5.  Adolescent brain development and depression: A case for the importance of connectivity of the anterior cingulate cortex.

Authors:  Sarah D Lichenstein; Timothy Verstynen; Erika E Forbes
Journal:  Neurosci Biobehav Rev       Date:  2016-07-25       Impact factor: 8.989

6.  Humeral Lengthening with the PRECICE Magnetic Lengthening Nail.

Authors:  Ahmed I Hammouda; Shawn C Standard; S Robert Rozbruch; John E Herzenberg
Journal:  HSS J       Date:  2017-04-21

7.  Site-specific Patient-reported Outcome Measures for Hand Conditions: Systematic Review of Development and Psychometric Properties.

Authors:  Justin C R Wormald; Luke Geoghegan; Kyra Sierakowski; Andrew Price; Michele Peters; Abhilash Jain; Jeremy N Rodrigues
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-05-21

8.  Rehabilitation Decision-making for Lower Extremity Sarcoma with Undiagnosed Metastases: A Case Report.

Authors:  Mary Alice Hewelt; Christopher M Wilson; Elyse A Mazurkiewicz
Journal:  Cureus       Date:  2019-08-20

9.  Clinical trial readiness to solve barriers to drug development in FSHD (ReSolve): protocol of a large, international, multi-center prospective study.

Authors:  Samantha LoRusso; Nicholas E Johnson; Michael P McDermott; Katy Eichinger; Russell J Butterfield; Elena Carraro; Kiley Higgs; Leann Lewis; Karlien Mul; Sabrina Sacconi; Valeria A Sansone; Perry Shieh; Baziel van Engelen; Kathryn Wagner; Leo Wang; Jeffrey M Statland; Rabi Tawil
Journal:  BMC Neurol       Date:  2019-09-10       Impact factor: 2.474

10.  Long non-coding RNA RP11-468E2.5 curtails colorectal cancer cell proliferation and stimulates apoptosis via the JAK/STAT signaling pathway by targeting STAT5 and STAT6.

Authors:  Li Jiang; Xu-Hai Zhao; Yin-Ling Mao; Jun-Feng Wang; Hui-Jun Zheng; Qing-Shan You
Journal:  J Exp Clin Cancer Res       Date:  2019-11-12
View more