Literature DB >> 25119299

Fundamental study of a real-time occupational dosimetry system for interventional radiology staff.

Yohei Inaba1, Koichi Chida, Ryota Kobayashi, Yuji Kaga, Masayuki Zuguchi.   

Abstract

Real-time monitoring of the radiation doses received by interventional radiology (IR) staff has become highly desirable. However, occupational doses are rarely measured in real time, due to the lack of a feasible method for use in IR. Recently, the i2 system by RaySafe™ has been introduced to measure occupational exposure in IR in real time. The i2 system consists of several personal dosimeters (PDs) and a base station with a display and computer interfacing. We evaluated the fundamental performance (dose linearity, dose-rate dependence, angular dependence, batch uniformity and reproducibility) of the i2 system. The dose linearity of the i2 was excellent (R(2) = 1.00) The i2 exhibited slight dose-rate dependence (~20%) at very high dose rates (250 mGy h(-1)). Little angular dependence (within 20%) was observed between 0° and ±45°, in either the vertical or horizontal direction. We also found that the PD was highly sensitive (about 200%) at angles behind it, e.g. 180°. However, this backscattered radiation is not a problem, in general, due to the placement of the i2 sensor (PD) on the lead apron. We conclude that the i2 system facilitates accurate real-time monitoring and management of occupational doses during IR.

Entities:  

Mesh:

Year:  2014        PMID: 25119299     DOI: 10.1088/0952-4746/34/3/N65

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  13 in total

1.  Effectiveness of a novel real-time dosimeter in interventional radiology: a comparison of new and old radiation sensors.

Authors:  Yohei Inaba; Masaaki Nakamura; Koichi Chida; Masayuki Zuguchi
Journal:  Radiol Phys Technol       Date:  2018-10-10

2.  The effectiveness of additional lead-shielding drape and low pulse rate fluoroscopy in protecting staff from scatter radiation during cardiac resynchronization therapy (CRT).

Authors:  Yoshiaki Morishima; Koichi Chida; Yoshiaki Katahira
Journal:  Jpn J Radiol       Date:  2018-10-15       Impact factor: 2.374

3.  Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians.

Authors:  Mime Endo; Yoshihiro Haga; Masahiro Sota; Akiko Tanaka; Kazuki Otomo; Yuuki Murabayashi; Mitsuya Abe; Yuji Kaga; Yohei Inaba; Msatoshi Suzuki; Taiichiro Meguro; Koichi Chida
Journal:  J Radiat Res       Date:  2021-05-12       Impact factor: 2.724

Review 4.  What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel?

Authors:  Koichi Chida
Journal:  Radiol Phys Technol       Date:  2022-05-24

5.  New Radioprotective Device that can be Used for Fluoroscopic Exam: Possibility to Contribute to Staff Exposure Protection During VFSS.

Authors:  Yoshiaki Morishima; Koichi Chida; Osamu Ito
Journal:  Dysphagia       Date:  2022-02-15       Impact factor: 3.438

6.  Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures.

Authors:  Hiroki Ishii; Koichi Chida; Ko Satsurai; Yoshihiro Haga; Yuji Kaga; Mitsuya Abe; Yohei Inaba; Masayuki Zuguchi
Journal:  Radiol Phys Technol       Date:  2022-01-23

7.  Effectiveness of additional lead shielding to protect staff from scattering radiation during endoscopic retrograde cholangiopancreatography procedures.

Authors:  Yoshiaki Morishima; Koichi Chida; Takayoshi Meguro
Journal:  J Radiat Res       Date:  2018-03-01       Impact factor: 2.724

8.  Development of Novel Real-Time Radiation Systems Using 4-Channel Sensors.

Authors:  Yohei Inaba; Masaaki Nakamura; Masayuki Zuguchi; Koichi Chida
Journal:  Sensors (Basel)       Date:  2020-05-11       Impact factor: 3.576

9.  Reduction of radiation exposure to operating physician and assistant using a real-time auditory feedback dosimeter during femoral artery puncturing: a study on swine model.

Authors:  Muhammad Umair Ahmad Khan; Byung-Ju Yi
Journal:  Eur Radiol Exp       Date:  2019-09-23

10.  Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy.

Authors:  Yoshihiro Haga; Koichi Chida; Yuichiro Kimura; Shinsuke Yamanda; Masahiro Sota; Mitsuya Abe; Yuji Kaga; Taiichiro Meguro; Masayuki Zuguchi
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

View more