Literature DB >> 25103262

Automated volumetric analysis of interface fluid in descemet stripping automated endothelial keratoplasty using intraoperative optical coherence tomography.

David Xu1, William J Dupps2, Sunil K Srivastava3, Justis P Ehlers3.   

Abstract

PURPOSE: We demonstrated a novel automated algorithm for segmentation of intraoperative optical coherence tomography (iOCT) imaging of fluid interface gap in Descemet stripping automated endothelial keratoplasty (DSAEK) and evaluated the effect of intraoperative maneuvers to promote graft apposition on interface dimensions.
METHODS: A total of 30 eyes of 29 patients from the anterior segment arm of the PIONEER study was included in this analysis. The iOCT scans were entered into an automated algorithm that delineated the spatial extent of the fluid interface gap in three dimensions between donor and host cornea during surgery. The algorithm was validated against manual segmentation, and performance was evaluated by absolute accuracy and intraclass correlation coefficient. Patients underwent DSAEK using a standard sequence of maneuvers, including controlled elevation of IOP and compressive corneal sweep to promote graft adhesion. Measurement of interface fluid volume, en face area, and maximal interface height were compared between scans before anterior chamber infusion, after pressure elevation alone, and after corneal sweep with pressure elevation using dependent-samples t-test.
RESULTS: The algorithm achieved 87% absolute accuracy and an intraclass correlation of 0.96. Nine datasets of a total of 84 (11%) required human correction of segmentation errors. Mean interface fluid volume was significantly decreased by corneal sweep (P = 0.021) and by both maneuvers combined (P = 0.046). Mean en face area was significantly decreased by corneal sweep (P = 0.010) and the maneuvers combined (P < 0.001). Maximal interface height was significantly decreased by pressure elevation (P = 0.010), corneal sweep (P = 0.009), and the maneuvers combined (P = 0.010).
CONCLUSIONS: Quantitative analysis of iOCT volumetric scans shows the significant effect of controlled pressure elevation and corneal sweep on graft apposition in DSAEK. Computerized iOCT analysis yields objective measurements of interface fluid intraoperatively, which provides information on anatomic outcomes and could be used in future trials. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

Entities:  

Keywords:  endothelial keratoplasty; interface; intraoperative; optical coherence tomography; volume

Mesh:

Year:  2014        PMID: 25103262      PMCID: PMC4160074          DOI: 10.1167/iovs.14-14346

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  32 in total

1.  Sutureless, posterior lamellar keratoplasty: a case report of a modified technique.

Authors:  Gerrit R J Melles; Frank Lander; Carla Nieuwendaal
Journal:  Cornea       Date:  2002-04       Impact factor: 2.651

2.  Descemet's stripping with endothelial keratoplasty in 200 eyes: Early challenges and techniques to enhance donor adherence.

Authors:  Francis W Price; Marianne O Price
Journal:  J Cataract Refract Surg       Date:  2006-03       Impact factor: 3.351

Review 3.  A new approach for endothelial transplantation: deep lamellar endothelial keratoplasty.

Authors:  Mark A Terry
Journal:  Int Ophthalmol Clin       Date:  2003

4.  Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging.

Authors:  Teresa C Chen; Barry Cense; Mark C Pierce; Nader Nassif; B Hyle Park; Seok H Yun; Brian R White; Brett E Bouma; Guillermo J Tearney; Johannes F de Boer
Journal:  Arch Ophthalmol       Date:  2005-12

5.  Simple technique to unfold the donor corneal lenticule during Descemet's stripping and automated endothelial keratoplasty.

Authors:  Steven B Koenig; William J Dupps; Douglas J Covert; David M Meisler
Journal:  J Cataract Refract Surg       Date:  2007-02       Impact factor: 3.351

6.  Use of an air-fluid exchange system to promote graft adhesion during Descemet's stripping automated endothelial keratoplasty.

Authors:  David M Meisler; William J Dupps; Douglas J Covert; Steven B Koenig
Journal:  J Cataract Refract Surg       Date:  2007-05       Impact factor: 3.351

7.  Descemet's stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue.

Authors:  Marianne O Price; Francis W Price
Journal:  Ophthalmology       Date:  2006-08-28       Impact factor: 12.079

8.  Descemet-stripping automated endothelial keratoplasty.

Authors:  Mark S Gorovoy
Journal:  Cornea       Date:  2006-09       Impact factor: 2.651

9.  Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK).

Authors:  Steven B Koenig; Douglas J Covert; William J Dupps; David M Meisler
Journal:  Cornea       Date:  2007-07       Impact factor: 2.651

Review 10.  Descemet's stripping endothelial keratoplasty.

Authors:  Marianne O Price; Francis W Price
Journal:  Curr Opin Ophthalmol       Date:  2007-07       Impact factor: 3.761

View more
  15 in total

Review 1.  Intraoperative optical coherence tomography: past, present, and future.

Authors:  J P Ehlers
Journal:  Eye (Lond)       Date:  2015-12-18       Impact factor: 3.775

2.  The DISCOVER Study 3-Year Results: Feasibility and Usefulness of Microscope-Integrated Intraoperative OCT during Ophthalmic Surgery.

Authors:  Justis P Ehlers; Yasha S Modi; Paula E Pecen; Jeff Goshe; William J Dupps; Aleksandra Rachitskaya; Sumit Sharma; Alex Yuan; Rishi Singh; Peter K Kaiser; Jamie L Reese; Carmen Calabrise; Allison Watts; Sunil K Srivastava
Journal:  Ophthalmology       Date:  2018-03-02       Impact factor: 12.079

3.  Intraoperative optical coherence tomography (RESCAN® 700) for detecting iris incarceration and iridocorneal adhesion during keratoplasty.

Authors:  Hiroshi Eguchi; Shunji Kusaka; Eiko Arimura-Koike; Kuniko Tachibana; Daishi Tsujioka; Masahiko Fukuda; Yoshikazu Shimomura
Journal:  Int Ophthalmol       Date:  2016-08-11       Impact factor: 2.031

Review 4.  [Intraoperative OCT in ophthalmic microsurgery].

Authors:  B V Stanzel; A Gagalick; C K Brinkmann; R Brinken; M C Herwig; F G Holz
Journal:  Ophthalmologe       Date:  2016-05       Impact factor: 1.059

5.  Intraoperative Interface Fluid Dynamics and Clinical Outcomes for Intraoperative Optical Coherence Tomography-Assisted Descemet Stripping Automated Endothelial Keratoplasty From the PIONEER Study.

Authors:  Katie M Hallahan; Brian Cost; Jeff M Goshe; William J Dupps; Sunil K Srivastava; Justis P Ehlers
Journal:  Am J Ophthalmol       Date:  2016-10-01       Impact factor: 5.258

6.  Automatic evaluation of graft orientation during Descemet membrane endothelial keratoplasty using intraoperative OCT.

Authors:  Marc B Muijzer; Friso G Heslinga; Floor Couwenberg; Herke-Jan Noordmans; Abdelkarim Oahalou; Josien P W Pluim; Mitko Veta; Robert P L Wisse
Journal:  Biomed Opt Express       Date:  2022-04-08       Impact factor: 3.562

7.  ELLIPSOID ZONE MAPPING AND OUTER RETINAL CHARACTERIZATION AFTER INTRAVITREAL OCRIPLASMIN.

Authors:  Yuji Itoh; Justis P Ehlers
Journal:  Retina       Date:  2016-12       Impact factor: 4.256

8.  Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: the DISCOVER Study RESCAN Results.

Authors:  Justis P Ehlers; Jeff Goshe; William J Dupps; Peter K Kaiser; Rishi P Singh; Richard Gans; Jonathan Eisengart; Sunil K Srivastava
Journal:  JAMA Ophthalmol       Date:  2015-10       Impact factor: 7.389

Review 9.  Clinical applications for intraoperative optical coherence tomography: a systematic review.

Authors:  Marc B Muijzer; Peter A W J Schellekens; Henny J M Beckers; Joke H de Boer; Saskia M Imhof; Robert P L Wisse
Journal:  Eye (Lond)       Date:  2021-07-16       Impact factor: 3.775

10.  Intraoperative optical coherence tomography in descemet stripping automated endothelial keratoplasty: pilot experiences.

Authors:  Jasper G Steverink; Robert P L Wisse
Journal:  Int Ophthalmol       Date:  2016-09-21       Impact factor: 2.031

View more