Literature DB >> 34272509

Clinical applications for intraoperative optical coherence tomography: a systematic review.

Marc B Muijzer1, Peter A W J Schellekens2, Henny J M Beckers3, Joke H de Boer2, Saskia M Imhof2, Robert P L Wisse2.   

Abstract

In this systematic review, we provide an overview of the current state of intraoperative optical coherence tomography (iOCT). As iOCT technology is increasingly utilized, its current clinical applications and potential uses warrant attention. Here, we categorize the findings of various studies by their respective fields, including the use of iOCT in vitreoretinal surgery, corneal surgery, glaucoma surgery, cataract surgery, and pediatric ophthalmology. The trend observed in recent decades towards performing minimally invasive ophthalmic surgery has caused practitioners to recognize the limitations of using a conventional surgical microscope for intraoperative visualization. Thus, the superior visualization provided by iOCT can improve the safety of these surgical techniques and promote the development of new minimally invasive ophthalmic surgeries. Landmark prospective studies found that iOCT can significantly affect surgical decision making and can cause a subsequent change in surgical strategy, and the use of iOCT has potential to improve surgical outcome. Despite these advantages, however, iOCT is still a relatively new technique, and beginning users of iOCT can encounter limitations that can preclude their reaching the full potential of iOCT and in this respect several improvements are needed.
© 2021. The Author(s), under exclusive licence to The Royal College of Ophthalmologists.

Entities:  

Mesh:

Year:  2021        PMID: 34272509      PMCID: PMC8807841          DOI: 10.1038/s41433-021-01686-9

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  107 in total

1.  Feasibility of intrasurgical spectral-domain optical coherence tomography.

Authors:  Susanne Binder; Christiane I Falkner-Radler; Christoph Hauger; Holger Matz; Carl Glittenberg
Journal:  Retina       Date:  2011 Jul-Aug       Impact factor: 4.256

2.  Scanning beyond the limits of standard OCT with a Fourier domain optical coherence tomography integrated into a slit lamp: the SL SCAN-1.

Authors:  M Stehouwer; F D Verbraak; H R de Vries; T G van Leeuwen
Journal:  Eye (Lond)       Date:  2010-11-12       Impact factor: 3.775

Review 3.  Optical coherence tomography - development, principles, applications.

Authors:  Adolf Friedrich Fercher
Journal:  Z Med Phys       Date:  2009-12-22       Impact factor: 4.820

4.  Intraoperative 2-dimensional optical coherence tomography as a new tool for anterior segment surgery.

Authors:  Gerd Geerling; Maya Müller; Christian Winter; Hans Hoerauf; Stefan Oelckers; Horst Laqua; Reginald Birngruber
Journal:  Arch Ophthalmol       Date:  2005-02

5.  Microscope-integrated intraoperative OCT with electrically tunable focus and heads-up display for imaging of ophthalmic surgical maneuvers.

Authors:  Yuankai K Tao; Sunil K Srivastava; Justis P Ehlers
Journal:  Biomed Opt Express       Date:  2014-05-20       Impact factor: 3.732

Review 6.  A view of the current and future role of optical coherence tomography in the management of age-related macular degeneration.

Authors:  U Schmidt-Erfurth; S Klimscha; S M Waldstein; H Bogunović
Journal:  Eye (Lond)       Date:  2016-11-25       Impact factor: 3.775

7.  In vivo optical coherence tomography.

Authors:  A F Fercher; C K Hitzenberger; W Drexler; G Kamp; H Sattmann
Journal:  Am J Ophthalmol       Date:  1993-07-15       Impact factor: 5.258

8.  Use of a new intra-ocular spectral domain optical coherence tomography in vitreoretinal surgery.

Authors:  Marco Mura; Danilo Iannetta; Francesco Nasini; Francesco Barca; Enrico Peiretti; Leonore Engelbrecht; Marc D de Smet; Frank Verbraak
Journal:  Acta Ophthalmol       Date:  2016-02-04       Impact factor: 3.761

9.  Integrative advances for OCT-guided ophthalmic surgery and intraoperative OCT: microscope integration, surgical instrumentation, and heads-up display surgeon feedback.

Authors:  Justis P Ehlers; Sunil K Srivastava; Daniel Feiler; Amanda I Noonan; Andrew M Rollins; Yuankai K Tao
Journal:  PLoS One       Date:  2014-08-20       Impact factor: 3.240

10.  Novel microscope-integrated stereoscopic heads-up display for intrasurgical optical coherence tomography.

Authors:  Liangbo Shen; Oscar Carrasco-Zevallos; Brenton Keller; Christian Viehland; Gar Waterman; Paul S Hahn; Anthony N Kuo; Cynthia A Toth; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2016-04-06       Impact factor: 3.732

View more
  4 in total

1.  Automatic evaluation of graft orientation during Descemet membrane endothelial keratoplasty using intraoperative OCT.

Authors:  Marc B Muijzer; Friso G Heslinga; Floor Couwenberg; Herke-Jan Noordmans; Abdelkarim Oahalou; Josien P W Pluim; Mitko Veta; Robert P L Wisse
Journal:  Biomed Opt Express       Date:  2022-04-08       Impact factor: 3.562

2.  Mesoporous Silica-Coated Gold Nanoparticles for Multimodal Imaging and Reactive Oxygen Species Sensing of Stem Cells.

Authors:  Chloe Trayford; Darragh Crosbie; Timo Rademakers; Clemens van Blitterswijk; Rudy Nuijts; Stefano Ferrari; Pamela Habibovic; Vanessa LaPointe; Mor Dickman; Sabine van Rijt
Journal:  ACS Appl Nano Mater       Date:  2022-03-14

Review 3.  Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery.

Authors:  Sang Beom Han; Yu-Chi Liu; Karim Mohamed-Noriega; Jodhbir S Mehta
Journal:  J Ophthalmol       Date:  2022-04-08       Impact factor: 1.974

Review 4.  The Development and Clinical Application of Innovative Optical Ophthalmic Imaging Techniques.

Authors:  Palaiologos Alexopoulos; Chisom Madu; Gadi Wollstein; Joel S Schuman
Journal:  Front Med (Lausanne)       Date:  2022-06-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.