BACKGROUND: There are still many questions related to aseptic femoral stem loosening. Systemic and local immune responses to the implanted "foreign body" is one of the reasons for loosening. The purpose of the study was to measure metal ion concentration (Ti, Co, Cr, Mo, Ni, Al) around loosened femoral stems and compare their levels around uncemented and cemented implants.Entities:
Mesh:
Substances:
Year: 2014 PMID: 25098913 PMCID: PMC4127068 DOI: 10.1186/1471-2474-15-267
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Metal ion concentrations in cemented and uncemented stems, together with statistical comparison
| Titanium | Cemented | 118.6 | 1196 | 516.7 | 423.4 | 303.2 | 58.7 | |
| Uncemented | 768.5 | 999999 | 55308.6 | 12268.6 | 197431.8 | 356.9 | ||
| Aluminium | Cemented | 103.5 | 1234.5 | 278.8 | 154.7 | 270.7 | 97.1 | |
| Uncemented | 567.8 | 7977.2 | 3779.8 | 3464.7 | 2374.0 | 62.8 | ||
| Nickel | Cemented | 38.8 | 204230.4 | 8580.5 | 365.5 | 40765.5 | 475.1 | z = 1.572; p > 0.05 |
| Uncemented | 54.4 | 1353.7 | 568.3 | 468.2 | 438.5 | 77.2 | ||
| Chrome | Cemented | 88.6 | 1494.6 | 532.3 | 347.5 | 451.6 | 84.8 | z = 0.854; p > 0.05 |
| Uncemented | 113.4 | 1345.8 | 553.7 | 455.7 | 347.8 | 62.8 | ||
| Cobalt | Cemented | 2.5 | 327.6 | 85.9 | 23.3 | 108.6 | 126.5 | z = 1.717; p > 0.05 |
| Uncemented | 11.2 | 367.3 | 124.4 | 44.8 | 126.3 | 101.5 | ||
| Molybdenum | Cemented | 32.9 | 47855.3 | 2165.2 | 198.8 | 9522.7 | 439.8 | z = 1.455; p > 0.05 |
| Uncemented | 12.9 | 999999 | 40787.9 | 444.7 | 199841.3 | 489.9 | ||
Min – minimum, max – maximum, x- mean, Me - median, SD – standard deviation , v (%) – variance, p – statistical significance (P – value), z – z value.