Literature DB >> 25096670

Shear bond strength between veneering composite and PEEK after different surface modifications.

Martin Rosentritt1, Verena Preis, Michael Behr, Nuno Sereno, Carola Kolbeck.   

Abstract

OBJECTIVES: This study aims to test the influence of different surface treatments and conditioning on the shear bond strength between polyetherketone (PEEK) and composite.
MATERIALS AND METHODS: Surfaces (570 plates) were used untreated, etched, air-particle abraded or activated with silica-modified alumina oxide. Surface roughness was determined after different treatments. Cylinders of composite were polymerized onto the surfaces. Eighteen different pre-treatment combinations were applied, partly combined with opaque application. Shear bond strength (SBS) was determined following ISO TR 11405. Baseline tests were performed 24 h after composite polymerization. For investigating the influence of storage and aging, the specimens were either stored in distilled water (37 °C, 90 days) or thermally cycled (12,000 cycles 5 °C/55 °C, distilled water). Means and standard deviations were calculated (statistics: one-way ANOVA/Bonferroni (α = 0.05)).
RESULTS: Surface roughness varied between 0.04 ± 0.01 and 6.76 ± 1.11 μm. Only etching caused a significant (p < 0.001) increase. SBS strongly varied between 0.0 ± 0.0 and 23.2 ± 2.1 MPa. After thermal cycling (TC), nine of the investigated systems showed SBS higher than 5 MPa, varying from 8.8 ± 2.7 MPa (#7) to 19.4 ± 2.5 MPa (#4). After water storage, nine systems provided SBS higher than 5 MPa, seven even values higher than 10 MPa. Maximum SBS was 27.1 ± 3.1 MPa (#2) and lowest value was 5.4 ± 2.6 MPa (#4). Significant (p < 0.001) differences were found between the individual systems after 24 h, TC and after 90 days storage.
CONCLUSIONS: For good bonding between PEEK and composite, cleaning and roughening is recommended. Surface conditioning prior to bonding seems essential. Combination with opaque revealed an increase in SBS. CLINICAL RELEVANCE: Successful bonding on PEEK surfaces can be achieved by surface roughening and subsequent surface activation with acetone- or phosphate-based methacrylate primers or tribochemical treatment.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25096670     DOI: 10.1007/s00784-014-1294-2

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  12 in total

1.  Retentive forces and fatigue resistance of thermoplastic resin clasps.

Authors:  Fahed Tannous; Martin Steiner; Ramez Shahin; Matthias Kern
Journal:  Dent Mater       Date:  2011-11-29       Impact factor: 5.304

2.  Stress shielding and fatigue limits of poly-ether-ether-ketone dental implants.

Authors:  Woo-Taek Lee; Jai-Young Koak; Young-Jun Lim; Seong-Kyun Kim; Ho-Beom Kwon; Myung-Joo Kim
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-02-14       Impact factor: 3.368

3.  The bond strength of the resin-to-zirconia interface using different bonding concepts.

Authors:  Michael Behr; Peter Proff; Carola Kolbeck; Sabine Langrieger; Johannes Kunze; Gerhard Handel; Martin Rosentritt
Journal:  J Mech Behav Biomed Mater       Date:  2010-08-27

Review 4.  [After titanium, peek ?].

Authors:  J-P Meningaud; F Spahn; J-M Donsimoni
Journal:  Rev Stomatol Chir Maxillofac       Date:  2012-08-30

5.  Fracture strength and failure mode of maxillary implant-supported provisional single crowns: a comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments.

Authors:  Hendrik Jacob Santing; Henny J A Meijer; Gerry M Raghoebar; Mutlu Özcan
Journal:  Clin Implant Dent Relat Res       Date:  2010-12-22       Impact factor: 3.932

6.  Adhesive bond of veneering composites on various metal surfaces using silicoating, titanium-coating or functional monomers.

Authors:  Michael Behr; Martin Rosentritt; Gerhard Gröger; Gerhard Handel
Journal:  J Dent       Date:  2003-01       Impact factor: 4.379

7.  Influence of surface conditioning on bonding to polyetheretherketon (PEEK).

Authors:  Matthias Kern; Frank Lehmann
Journal:  Dent Mater       Date:  2012-10-02       Impact factor: 5.304

8.  Influence of plasma pretreatment on shear bond strength of self-adhesive resin cements to polyetheretherketone.

Authors:  B Stawarczyk; N Bähr; F Beuer; T Wimmer; M Eichberger; W Gernet; D Jahn; P R Schmidlin
Journal:  Clin Oral Investig       Date:  2013-03-17       Impact factor: 3.573

9.  Polyetheretherketone-a suitable material for fixed dental prostheses?

Authors:  Bogna Stawarczyk; Florian Beuer; Timea Wimmer; Dirk Jahn; Beatrice Sener; Malgorzata Roos; Patrick R Schmidlin
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-04-06       Impact factor: 3.368

10.  Nano-TiO2/PEEK bioactive composite as a bone substitute material: in vitro and in vivo studies.

Authors:  Xiaomian Wu; Xiaochen Liu; Jie Wei; Jian Ma; Feng Deng; Shicheng Wei
Journal:  Int J Nanomedicine       Date:  2012-03-05
View more
  12 in total

1.  Bonding of composite resins to PEEK: the influence of adhesive systems and air-abrasion parameters.

Authors:  Bogna Stawarczyk; Simon Taufall; Malgorzata Roos; Patrick R Schmidlin; Nina Lümkemann
Journal:  Clin Oral Investig       Date:  2017-06-24       Impact factor: 3.573

2.  Comparative Evaluation of Tensile Bond Strength of Poly Ether Ether Ketone (PEEK) and Zirconia Copings Using Resin Cement with or without Adhesive: An In Vitro Study.

Authors:  Nimisha Kakkad; Naveen S Yadav; Puja Hazari; Shweta Narwani; Kirti Somkuwar; Sakeenabi Basha; Varsha Verma; Suraj Arora; Omir Aldowah; Artak Heboyan; Mohmed Isaqali Karobari
Journal:  Materials (Basel)       Date:  2022-06-12       Impact factor: 3.748

3.  Comparison of the Bond Strength of Composite Resin to Zirconia and Composite Resin to Polyether Ether Ketone: An In Vitro Study.

Authors:  Hasan Sarfaraz; Mohammed N Rasheed; Sanath K Shetty; Uma M Prabhu; Kevin Fernandes; Smrithi Mohandas
Journal:  J Pharm Bioallied Sci       Date:  2020-08-28

4.  Evaluation of the failure modes and load-bearing capacity of different surface-treated polyether ether ketone copings veneered with lithium di-silicate compared to polyether ether ketone copings veneered with composite: An in vitro study.

Authors:  Abhishek Kumar Gupta; Rekha Gupta; Shubhra Gill
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

5.  Fracture load and failure types of different veneered polyetheretherketone fixed dental prostheses.

Authors:  Simon Taufall; Marlis Eichberger; Patrick R Schmidlin; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2016-03-15       Impact factor: 3.573

6.  Discoloration of PMMA, composite, and PEEK.

Authors:  Sina Heimer; Patrick R Schmidlin; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2016-06-25       Impact factor: 3.573

7.  Evaluation of the effects of different surface modification methods on the bond strength of high-performance polymers and resin matrix ceramics.

Authors:  Büşra Tosun; Nuran Yanıkoğlu
Journal:  Clin Oral Investig       Date:  2022-01-24       Impact factor: 3.573

8.  Zirconia implants and peek restorations for the replacement of upper molars.

Authors:  José María Parmigiani-Izquierdo; María Eugenia Cabaña-Muñoz; José Joaquín Merino; Arturo Sánchez-Pérez
Journal:  Int J Implant Dent       Date:  2017-02-20

9.  The Effect of Various Plasma Gases on the Shear Bond Strength between Unfilled Polyetheretherketone (PEEK) and Veneering Composite Following Artificial Aging.

Authors:  Mohamed Younis; Alexey Unkovskiy; Ashraf ElAyouti; Jürgen Geis-Gerstorfer; Sebastian Spintzyk
Journal:  Materials (Basel)       Date:  2019-05-04       Impact factor: 3.623

10.  Digitally Fabricated Dentures for Full Mouth Rehabilitation with Zirconia, Polyetheretherketone and Selective Laser Melted Ti-6Al-4V Material.

Authors:  Wei-Ting Lee; Yung-Chung Chen
Journal:  Int J Environ Res Public Health       Date:  2022-03-04       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.