Literature DB >> 25061453

Early outcomes of transcatheter aortic valve replacement in patients with severe aortic stenosis: single center experience.

Engin Bozkurt1, Telat Keleş1, Tahir Durmaz1, Murat Akçay1, Cenk Sari2, Hüseyin Ayhan1, Nihal Akar Bayram1, Abdullah Nabi Aslan2, Serdal Baştuğ2, Emine Bilen2.   

Abstract

INTRODUCTION: Transcatheter aortic valve implantation is a promising alternative to high risk surgical aortic valve replacement. The procedure is mainly indicated in patients with severe symptomatic aortic stenosis who cannot undergo surgery or who are at very high surgical risk. AIM: Description early results of our single-center experience with balloon expandable aortic valve implantation.
MATERIAL AND METHODS: Between July 2011 and August 2012, we screened in total 75 consecutive patients with severe aortic stenosis and high risk for surgery. Twenty-one of them were found ineligible for transcatheter aortic valve implantation (TAVI) because of various reasons, and finally we treated a total of 54 patients with symptomatic severe aortic stenosis (AS) who could not be treated by open heart surgery (inoperable) because of high-risk criteria. The average age of the patients was 77.4 ±7.1; 27.8% were male and 72.2% were female. The number of patients in NYHA class II was 7 while the number of patients in class III and class IV was 47.
RESULTS: The average mortality score of patients according to the STS scoring system was 8.5%. Pre-implantation mean and maximal aortic valve gradients were measured as 53.2 ±14.1 mm Hg and 85.5 ±18.9 mm Hg, respectively. Post-implantation mean and maximal aortic valve gradients were 9.0 ±3.0 and 18.2 ±5.6, respectively (p < 0.0001). The left ventricular ejection fraction was calculated as 54.7 ±14.4% before the operation and 58.0 ±11.1% after the operation (p < 0.0001). The duration of discharge after the operation was 5.29 days, and a statistically significant correlation between the duration of discharge after the operation and STS was found (r = 0385, p = 0.004).
CONCLUSIONS: We consider that with decreasing cost and increasing treatment experience, TAVI will be used more frequently in broader indications. Our experience with TAVI using the Edwards-Sapien XT (Edwards Lifesciences, Irvine, CA) devices suggests that this is an effective and relatively safe procedure for the treatment of severe aortic stenosis in suitable patients.

Entities:  

Keywords:  transcatheter aortic valve replacement

Year:  2014        PMID: 25061453      PMCID: PMC4108731          DOI: 10.5114/pwki.2014.43511

Source DB:  PubMed          Journal:  Postepy Kardiol Interwencyjnej        ISSN: 1734-9338            Impact factor:   1.426


Introduction

Severe symptomatic aortic stenosis has a poor prognosis with conservative treatment [1]. If patients are left untreated, appearance of symptoms results in a high rate of death: approximately 30–50% in the first 2 years after symptoms appear [2-4]. Because aortic stenosis is an old-age disease, comorbid situations are usually more frequent in these patients. This situation also makes surgery difficult. In fact, in clinical practice 30% of severe symptomatic patients cannot be operated on due to multiple coexisting conditions [5-8]. Transcatheter aortic valve implantation (TAVI) was applied in 2002 for the first time in humans by Cribier et al., and a very important alternative treatment had emerged [9]. Since this successful implantation, the reliability of the method has been demonstrated by many observational and randomized (PARTNER) studies, and the method has provided a significant improvement for symptomatic aortic stenosis (AS) patients who cannot undergo surgery compared to drug treatment [10]. Despite the wide range of application in Europe and in the United States, the use of TAVI in Turkey was tardily started in 2009 [11]. As far as we know, our clinic has become a center with one of the most extensive series in Turkey with respect to balloon expandable aortic valve implantation.

Aim

In the present article, we aim to share the results from our clinic as a single-center experience.

Material and methods

Between July 2011 and August 2012, we screened in total 75 patients who had severe aortic stenosis and high risk for surgery. Twenty-one of them were found ineligible for TAVI because of the reasons listed as follows: two of them had a very critical health status (severe left ventricular dysfunction and cardiogenic shock) and we performed balloon aortic valvuloplasty (BAV) as a bridge surgery but patients were lost because of cardiogenic shock. Six of them refused both surgery and TAVI. Four of them were found unsuitable for TAVI and surgery because of incurable malignancy (2) (life expectancy < 1 year), and severe neurological deficits in which cases the TAVI procedure was not expected to improve the patient's functional status or quality of life [2]. Nine of them were found suitable for surgery with the decision of the ‘'heart team’’ consisting of cardiologist, heart surgeon, anesthesiologist and radiologist (low risk or two valve disease). Finally, we performed TAVI with an Edwards Sapien XT valve (Edwards Lifesciences, Irvine, CA) in a total of 54 patients who were admitted to our clinic with symptomatic severe AS who could not undergo surgery because of high-risk criteria.

Inclusion criteria

Patients had to primarily fulfill the criteria of severe symptoms (according to New York Heart Society class II, III and IV) and echocardiographically important AS (aortic valve area < 0.8 cm2, mean systolic aortic valve pressure gradient > 40 mm Hg or aortic velocity 4.0 m/s). In addition, the peripheral vascular bed had to be wide enough for the process (> 6.0 mm) and the aortic annulus diameter 18–28 mm. Patients fitting the above criteria went through evaluation by the heart team. After evaluation of those who were appropriate as being inoperable for aortic valve replacement, or who had a very high risk for an operation, a plan was made for a TAVI procedure. Of those patients, those with comorbidities such as malignancy or liver cirrhosis were evaluated by the experts of the corresponding branch. The patients with an expected life-span longer than 1 year were considered to be suitable for the TAVI procedure. The risk assessment of patients was calculated according to the Society of Thoracic Surgeons (STS) scoring system [12].

Transcatheter aortic valve implantation procedure exclusion criteria

Patients with bicuspid aortic valve, non-calcified aortic stenosis, unsuitable annulus diameter, a history of stroke within the last 6 months, a life expectancy less than 1 year due to comorbidities, or an additional comorbidity that prevented any symptomatic relief as a result of TAVI were excluded from the study.

Imaging procedures

First, all patients were evaluated by transthoracic echocardiography (TTE), and then patients lacking contraindications for TAVI were evaluated by transesophageal echocardiography (TEE). In these evaluations, left ventricular function, aortic valve structure, degree of calcification and stenosis, and aortic valve area, annulus and ascending aorta measurements were recorded. Annulus measurements were performed with both TTE and TEE. During annulus measurements, the points of valve linked to aorta (hinge point to hinge point) were confirmed through zooming and then measurements were obtained. The annulus measurements in patients contraindicated with TEE were performed by TTE and computed tomography (CT). All of the patients before the operation underwent a 3D reconstruction process through contrast-enhanced CT imaging. Both annulus diameters and the distance of coronary arteries to annulus calculated by CT and also the diameters of arteries to be implemented (femoral artery, subclavian artery, abdominal aorta), calcification degree, tortuosity, and the division level of superficial and profunda femoral artery branches were detected. The patients with insufficient femoral artery diameter (< 6 mm), having severe tortuosity, calcification or significant narrowing of the arteries above the femoral artery level were treated through a subclavian route. Coronary angiography procedures were performed for all patients before the TAVI operation. After coronary angiography, patients requiring revascularization were given revascularization before TAVI. In addition, in order to determine the peripheral insertion site, angiography was performed using the digital subtraction technique in a manner to visualize the iliac and femoral arteries.

Transcatheter aortic valve implantation procedure

All TAVI procedures were performed in the catheter laboratory under local anesthesia along with deep sedation or general anesthesia. Despite the use of TEE with most of the patients, TEE was not applied for 1 patient with esophageal varices and 1 patient with esophageal stricture depending on exposure to corrosive substances. The artery in which the valve was to be moved was opened by surgical cut down in 8 patients. Five of them were the femoral artery and 3 of them were subclavian arteries. In the remaining 46 patients, TAVI was performed using the Prostar® XL (ProStar™ XL10Fr, Abbott Vascular, Abbott Park, IL, USA) closure system through an entirely percutaneous technique. Details of the device and technical aspects of the procedure have been previously published [13]. During Edwards Sapien XT valve implantation, attention was paid to the prosthetic valve to position it in the middle (50% – 50%), according to the annulus line using both TEE and angiographic imaging. Aortic root angiography was performed after the procedure to evaluate aortic insufficiency, valve position, flow in coronary arteries, and Valve Academic Research Consortium (VARC) specifications [14]. The peripheral entry site was then closed and angiographic control was performed. Peripheral blood vessels were evaluated especially for complications such as dissection, rupture and blockage. In case of detection of any complication, it was treated by peripheral stenting or a surgical method. During procedure, a bolus of intravenous heparin (60 IU/kg) was administered to achieve a target activated clotting time (ACT) of 250 s to 300 s, and the ACT was measured every 30 min thereafter. If the target ACT isn't achieved, an additional bolus dose according to ACT level were added.

Follow-up after transcatheter aortic valve implantation procedure

We followed our patients clinically and echocardiographically immediately after the procedure in the operating room by TEE and at predischarge, 1 month, 3 months, 6 months after discharge by TTE. Dual (aspirin and clopidogrel) antiplatelet therapy was given to all patients for up to 6 months. In situations where use of oral anticoagulant therapy was essential after the procedure, such as in atrial fibrillation, warfarin therapy was started for 1 month to an INR value around 2–2.5 and combined with dual antiplatelet therapy. One month later, aspirin and warfarin therapy were continued while stopping use of clopidogrel. Cardiovascular events and clinical endpoints were recorded according to the VARC classification.

Statistical analysis

Statistics in the present study were performed using the SPSS package (SPSS Inc., Chicago, Illinois, USA) version 17.0. Data containing continuous quantitative variables and categorical variables are shown in the form of mean ± standard deviation and percentage (%), respectively. The t-test was used to compare the means of pre- and post-operation parametric variables, while non-parametric parameters were evaluated by Wilcoxon test. Value of p < 0.05 was considered to be statistically significant.

Results

The present study contains the in-hospital and short-term (30-day and 180-day) results of 54 TAVI cases (39 women, 15 men, average age 77.4 ±7.1 years) who were treated in our hospital between July 2011 and August 2012. All of the patients had been considered either too risky for open-heart surgery or inoperable because of severe calcific aortic stenosis due to additional cardiovascular or other systemic diseases. General characteristics of the patients are summarized in Table I. The average age of patients was 77.4 ±7.1 years with 27.8% male and 72.2% female. The number of patients in NYHA class II was 7 while the number of patients in class III and class IV was 47. The average mortality score of patients according to the STS scoring system was 8.5%. According to the SURTAVI risk model, 5 patients had low risk, 14 patients had intermediate risk and 35 had high risk.
Table I

General characteristics

Patient characteristicsResults
Male/female, n 15/39
Age, mean ± SD [years]77.4 ±7.1 (46–97)
BMI, mean (range) [kg/m2]26.7 (17–36.9)
Functional capacity (NYHA class II), n 7
NYHA class III or IV, n 47
STS score8.5 (1.2–31.2)
SURTAVI risk model (low/intermediate/high), n 5/14/35
Comorbid conditions Results
Coronary artery disease, n 36
Hypertension, n 43
Diabetes mellitus, n 16
COPD (moderate to severe), n 32
Impaired renal function (creatinine > 1.3 mg/dl), n 13
Liver function disorder, n 1
Peripheral arterial disease (carotid, renal, distal extremity)26
Atrial fibrillation, n 13
Pre-operation revascularization, n 10
Annulus-LMCA distance [cm]12.7
General characteristics As comorbidity factors, 79.6% of our patients had hypertension, 29.6% had diabetes mellitus, 62% had moderate-to-severe chronic obstructive pulmonary disease, and 53.1% had peripheral artery disease (carotid, renal, and distal peripheral artery disease). 66.7% of the patients had coronary artery disease and 27.7% had coronary revascularization before the procedure. There were patients among our cases having mitral valve replacement (1), cirrhosis (1), hematologic malignancy (2), and left atrial thrombi (5), which were exclusion criteria of the Partner cohort A/B study. Pre-implantation mean and maximal aortic valve gradients were measured as 53.2 ±14.1 mm Hg and 85.5 ±18.9 mm Hg, respectively. Post-implantation mean and maximal aortic valve gradients were 9.0 ±3.0 and 18.2 ±5.6, respectively (p < 0.0001). The left ventricular ejection fraction was calculated as 54.7 ±14.4% before the operation and 58.0 ±11.1% after the operation (p < 0.0001). After the procedure, moderate (2) degrees of paravalvular aortic regurgitation were observed in 2 patients and mild degrees of paravalvular aortic regurgitation were found in 21 patients. Before the intervention, 2nd-3rd degree mitral regurgitation was seen in 15 patients while it was observed in only 1 patient after TAVI (Tables II, III).
Table II

Baseline echocardiographic variables

Echocardiographic variablesResults
Aortic annulus diameter, mean (range) [cm]20.8 (18–24)
AVA, mean (range) [cm2]0.65 (0.4–0.8)
Severe left ventricular dysfunction (EF < 35%), n 8
Mild aortic regurgitation, n 23
Moderate aortic regurgitation, n 14
Severe aortic regurgitation, n 1
Peak systolic pulmonary artery pressure, mean (range) [mm Hg]45.5 (30–70)
Table III

Echocardiographic variables before and after TAVI

Echocardiographic variablesBefore TAVIAfter TAVIValue of p
Maximal gradient, mean ± SD [mm Hg]85.5 ±18.918.2 ±5.6< 0.0001
Average gradient, mean ± SD [mm Hg]53.2 ±14.19.0 ±3.0< 0.0001
EF, mean ± SD (%)54.7 ±14.458.0 ±11.1< 0.0001
Mitral regurgitation moderate/high, n 151
Baseline echocardiographic variables Echocardiographic variables before and after TAVI Our technical success rate (defined as stable device placement and adequate function in the first attempt as assessed by angiography + echocardiography) was 98.0%. Our acute procedural success rate (defined as device success with the absence of periprocedural major cardiovascular events including death, tamponade, coronary artery occlusion in the first 24 h after device implantation) was 92.5% (50 of 54). Whereas the average procedure time was 75.5 min, it was noted to decrease to 68.5 min in the last 10 patients. The amount of contrast dye used during the process was 211 ml. The duration of discharge after the operation was 5.29 days and a statistically significant correlation was found between the duration of discharge after the operation and STS (r = 0385, p = 0.004) (Table IV).
Table IV

Procedural characteristics

Procedural characteristicsResults
Valve diameter (23 mm/26 mm)35/19
Prostar closure/surgery, n 46/8
Operation time, mean (range) [min]75.5 (44–164)
Contrast volume, mean (range) [ml]211 (100–350)
Post-operation discharge time, mean (range) [days]5.29 (3–20)
Procedural characteristics No clinical stroke was observed in our series. Pericardial effusion requiring surgical intervention was observed in 2 patients. None of the patients required permanent pacemaker implantation. In 1 patient, transient atrioventricular block occurred. He was monitored carefully and after 6 h the block disappeared and there was no need for permanent pacemaker implantation. Left bundle branch block developed in 1 patient after the procedure. The Prostar closure system was preferred in 46 patients and a surgical method was preferred in 8 patients for the access. Four of the patients that used Prostar required surgical repair due to peripheral dissection and 1 patient was treated with peripheral stenting. Bleeding, vascular access site and prosthetic valve ‘associated’ complications are listed in Table V.
Table V

Bleeding, vascular access site and prosthetic valve ‘associated’ complications

ComplicationsPatientPercent
Myocardial infarction (< 72 h)00
Stroke00
Vascular complications:
 Major23.7
 Minor35.5
Bleeding:
 Life-threatening35.55
 Major59.2
 Minor47.4
Pericardial effusion (requiring operation)23.7
Paravalvular aortic regurgitation (none/trace/mild/moderate/high)16/15/21/2/029.6/27.7/38.8/3.7/0
Temporary during the procedure/complete AV block1/01.85/0
Permanent pace maker implantation00
Acute renal failure (stage 1/2/3)3/0/05.55
Repeat TAVI (valve in valve)11.85
Endocarditis00
Valve embolization00
Coronary obstruction00
Bleeding, vascular access site and prosthetic valve ‘associated’ complications

Clinical follow-up

Our patients’ survival rate was 94.4% at the 180-day follow-up. One patient died as a result of right ventricular rupture due to the pacemaker lead 10 h after TAVI and 1 patient died in the cath lab as a result of left ventricular rupture immediately after valve implantation. After the discharge, no additional deaths were seen in the first month. In the 1 to 6 months period, 1 patient died due to internal bleeding (while using warfarin + ASA depending on atrial fibrillation). The 30-day mortality rate was 3.7% while the 180-day mortality rate was 5.55%. Although before receiving TAVI 87% of patients were in NYHA class III or IV, 78% of the surviving patients were in NYHA functional class I or II at 180-day follow-up. Composite end points according to VARC definitions are given in Table VI.
Table VI

TAVI results (composite end points defined by VARC)

VariablesPatientPercent
In-hospital death, n 23.7
30-day mortality, n:
 All-cause mortality23.7
 Cardiovascular-cause mortality23.7
180-day mortality, n 35.55
Successful placement of the device5398
Combined security end point (30 days)712.9
Combined security end point (180 days)35.55
Paravalvular aortic regurgitation (none/trace/mild/moderate/high at 3 months)11/18/23/2/020.4/33.4/42.5/3.7/0
Paravalvular aortic regurgitation (none/trace/mild/moderate/high at 6 months)11/18/23/2/020.4/33.4/42.5/3.7/0
TAVI results (composite end points defined by VARC)

Echocardiographic follow-up

At the echocardiographic examinations which were done at 1, 3 and 6 months after TAVI no deterioration was observed in patients with moderate aortic regurgitation. Changes in the degree of aortic regurgitation at 3- and 6-month follow up are given in Table VI. There was minimal worsening in the degree of aortic regurgitation in patients who had previously no or a trace degree of AR after the TAVI procedure (5 patients none to trace degree, 2 patient trace to mild degree).

Discussion

This study included in-hospital, 30-day and average 180-day clinical follow-up results of a total of 54 TAVI procedures performed in our clinic using transfemoral and subclavian artery methods. Our study contains the results of one of the largest series conducted with balloon expandable valve implantation in a single center in Turkey. The average age of our patients is similar to those included in the Europe SOURCA [15], German [16], and French [17] studies in addition to the PARTNER study [10]. However, the number of female patients in our series was greater than the number of male patients, which is different than the mentioned studies. The reason for this may be the particular distribution of the elderly population in our country, according to gender. The elderly female population in our country is higher than male (according to Turkish Statistical Institute data, the male/female ratio over the age of 80 is approximately 1.8) [18]. Our technical success rate for the TAVI procedure was 98%. Only in 1 patient did the valve move up slightly during valve emplacement. By placing a second valve, the procedure was successfully completed in this patient. Post-operation average gradient also yielded similar results to the other studies. Most of the TAVI procedures in our series were performed via the transfemoral method (51) and used a Prostar closure device (46). Three patients had Edwards Sapien XT valve implantation by a surgical technique through the subclavian artery. There are many reports about TAVI-associated complications. Stroke, pericardial tamponade, severe paravalvular aortic regurgitation, aortic dissection, aortic or cardiac rupture, and the complications in peripheral implantation site are the most serious ones. The other more commonly seen serious complications in patients especially having Corevalve self-expandable valve replacement have the need of permanent pacemaker implantation after intermittent or permanent third-degree block. In our series, only 1 patient developed 6-hour lasting transient AV complete block and a permanent pacemaker requirement did not occur. One patient developed a left branch block after the procedure, but no problem was seen in the follow-ups and the patient was discharged without any intervention. Both patients were monitored by a Holter device at the 1st month control, and no transient AV block was seen. The lowest need for a permanent pacemaker reported with the Edwards valve is in the studies of Sinhal et al. (5.7%) [19] and the Europe SOURCE [15] registry (7%). The reasons why none of the patients needed a permanent pacemaker implantation are most likely due to the small number of patients in our series, but also patient selection and not proceeding much toward the left ventricular outflow tract. Especially during valve implantation, the prosthesis valves are implanted by evaluating the valve position very carefully by TEE and/or angiographically and by considering the point where native aortic valves attach to the aorta (considering a 50% – 50% or at worst 60% – 40% rate). Pericardial effusion is a commonly seen complication that may cause fatal consequences by proceeding in tamponade. Data from the literature reveal an incidence of pericardial tamponade of 2–8% [20-23]. Especially the temporary pacemaker lead placed into the right ventricle may damage the thin wall of the right ventricle while beating too fast or may cause pericardial tamponade by tearing the wall [13]. In this case, the pericardial fluid must be immediately drained and in very rare cases the ventricular wall must be repaired if necessary. In our series, only 2 in-hospital deaths were reported and the reason for the first case was right ventricle rupture while the reason for the other was left ventricle rupture. Because this is a very serious and fatal complication, patients must be monitored by serial echocardiographic evaluation after the operation and the cardiac surgeons must be aware of the situation as soon as possible, keeping the operating room ready in case of emergency. One of the most commonly seen complications in TAVI is vascular complications and our series showed similar results as the others. The major peripheral complication rate was 16% in the PARTNER study [10], 6.3% in the French registry study containing Edwards valve replacement, and 3.7% in our series [17]. Despite the increased mortality rate in patients with vascular complications [17], no mortality was observed in our patients who had vascular complications [24-26]. Although in one study it was reported that vascular complications had fatal results and this was mostly related to the Prostar closure device, no fatal bleeding complications related to the Prostar closure device were seen in our study [27]. A need for surgical repair emerged in 2 patients due to the vascular complication related to the Prostar closure device. Before the use of the Prostar device, evaluation of the diameter, degree of calcification and tortuosity conditions of the peripheral arteries used for access are highly important to reduce peripheral complications. If the femoral artery is planned to be used as an access in the TAVI procedure, the division points of superficial and profunda branches should be clearly determined by both CT angiography and peripheral digital subtraction angiography and the intervention should be performed above this division point. Stroke is one of the important and catastrophic complications of TAVI and its rate was 4.6% in the PARTNER [10] study. Stroke was most commonly observed during implantation and position setting of the valve. In our series none of the patients had stroke. This is because we followed up our patients clinically with neurological examination and we did not use brain magnetic resonance imaging (MRI) routinely. Paravalvular aortic regurgitation was the most common complication of TAVI. In our series, 15 (27.7%) patients had a trace degree, 21 (38.8%) patients had a mild degree and 2 (3.7%) patients showed a moderate degree of paravalvular AR. No severe AR was observed in any patient immediately after the procedure or during 6-month follow-up. At the 6-month follow-up of patients with moderate aortic regurgitation, no increase was detected in the degree of AR. The rate of moderate-to-severe paravalvular AR in the literature is reported as 7–30% [10, 15, 16]. In our series, lack of severe AR might be explained by proper selection of the appropriate aortic valve size for the annulus. In our clinic, we decided on the optimal valve size by performing TTE, TEE, 3-dimensional TEE and CT measurements before the procedure. In some studies that compared 3-dimensional TEE measurements to 2-dimensional measurements, 3D TEE led to a change in the decision of the size of the prosthetic valve in approximately 26% of patients. This finding emphasizes the importance of 3-dimensional TEE in measurement and verification of the best-suited valve size [10, 15, 28, 29]. Annulus measurements with 3-dimensional multislice computed tomography offers the possibility of measuring the value that is closest to reality. Similar to 3-dimensional echo, measurements made with multislice computed tomography have been shown to change the TAVI strategy by 40% [30]. However, lack of specialized radiologists in this field is the biggest handicap and it forces us as cardiologists to consult three-dimensional TEE measurements more often. For this reason, a multidisciplinary team approach, including a permanent radiologist in the TAVI team to evaluate peripheral arteries and to try to obtain the most appropriate measures in annulus measurements with team-work, would be reasonable. At baseline echocardiographic evaluation, 15 patients had 2nd–3rd degree mitral regurgitation while it was observed in only 1 patient after the TAVI. Similarly, in a study conducted by Webb et al. [31] in 48% of patients with moderate to severe MR, MR regressed after TAVI. The pathophysiological mechanism behind this improvement can be explained as follows: as a result of longstanding severe AS, chronic pressure load results in concentric hypertrophy of the left ventricle and a high transmitral pressure gradient. As a result, MR can progress or functional MR can develop. Because of concomitant volume load, and development of diastolic dysfunction, mitral annular dilatation leads to progression of functional MR [32]. Most of our patients with MR had normal or nearly normal mitral valve structure called functional mitral regurgitation and therefore MR improved significantly after TAVI. Our in-hospital mortality rate (3.7%) and 30-day mortality rate (3.7%) were lower than those in the German registry study (8.2%/12.4%) and the average 180-day mortality rate (5.5%) was lower than those in many larger studies [10, 15–17]. These findings might be due to the relatively low risk score in our patients and being rigorous both in patient selection and in the evaluation of patients before the TAVI operation. The small number of patients is the major limitation of our study and this may have caused a lower adverse event rate compared with larger studies.

Conclusions

The TAVI method has been rapidly improving as a crucial and vital alternative for patients who are inoperable or who have a high risk for surgery due to comorbid conditions. Patient selection for TAVI is of considerable importance in optimizing procedural and long-term outcomes. It is important for cardiologists in our country to refer patients with severe aortic stenosis after diagnosis to the centers performing TAVI in order to assess the possibility of TAVI use. Thereby, at a time when tens of thousands of patients with aortic stenosis have been treated in Europe and America, it would be more widespread for people in our country as well.
  30 in total

1.  Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation.

Authors:  Oliver Husser; Simon Rauch; Dierk H Endemann; Markus Resch; Julio Nunez; Vicente Bodi; Michael Hilker; Christof Schmid; Günter A J Riegger; Andreas Luchner; Christian Hengstenberg
Journal:  Catheter Cardiovasc Interv       Date:  2012-03-14       Impact factor: 2.692

2.  Evaluation of patients with severe symptomatic aortic stenosis who do not undergo aortic valve replacement: the potential role of subjectively overestimated operative risk.

Authors:  David S Bach; Derrick Siao; Steven E Girard; Claire Duvernoy; Benjamin D McCallister; Sarah K Gualano
Journal:  Circ Cardiovasc Qual Outcomes       Date:  2009-10-27

3.  Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve Revalving system.

Authors:  Eberhard Grube; Lutz Buellesfeld; Ralf Mueller; Barthel Sauren; Bernfried Zickmann; Dinesh Nair; Harald Beucher; Thomas Felderhoff; Stein Iversen; Ulrich Gerckens
Journal:  Circ Cardiovasc Interv       Date:  2008-12       Impact factor: 6.546

4.  Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description.

Authors:  Alain Cribier; Helene Eltchaninoff; Assaf Bash; Nicolas Borenstein; Christophe Tron; Fabrice Bauer; Genevieve Derumeaux; Frederic Anselme; François Laborde; Martin B Leon
Journal:  Circulation       Date:  2002-12-10       Impact factor: 29.690

5.  Prognosis of congestive heart failure in patients aged > or = 62 years with unoperated severe valvular aortic stenosis.

Authors:  W S Aronow; C Ahn; I Kronzon; M Nanna
Journal:  Am J Cardiol       Date:  1993-10-01       Impact factor: 2.778

6.  Transcatheter aortic valve implantation: first results from a multi-centre real-world registry.

Authors:  Ralf Zahn; Ulrich Gerckens; Eberhard Grube; Axel Linke; Horst Sievert; Holger Eggebrecht; Rainer Hambrecht; Stefan Sack; Karl Eugen Hauptmann; Gert Richardt; Hans-Reiner Figulla; Jochen Senges
Journal:  Eur Heart J       Date:  2010-09-23       Impact factor: 29.983

7.  Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

Authors:  Antonio E Dager; Rutger-Jan Nuis; Bernardo Caicedo; Jaime A Fonseca; Camilo Arana; Lidsa Cruz; Luis M Benitez; Carlos A Nader; Eduardo Duenas; Eduardo J de Marchena; William W O'Neill; Peter P de Jaegere
Journal:  Tex Heart Inst J       Date:  2012

8.  The transapical approach for aortic valve implantation.

Authors:  Andreas Zierer; Gerhard Wimmer-Greinecker; Sven Martens; Anton Moritz; Mirko Doss
Journal:  J Thorac Cardiovasc Surg       Date:  2008-10       Impact factor: 5.209

9.  Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience.

Authors:  Alain Cribier; Helene Eltchaninoff; Christophe Tron; Fabrice Bauer; Carla Agatiello; Deborah Nercolini; Sydney Tapiero; Pierre-Yves Litzler; Jean-Paul Bessou; Vasilis Babaliaros
Journal:  J Am Coll Cardiol       Date:  2006-02-09       Impact factor: 24.094

10.  Contemporary surgical or percutaneous management of severe aortic stenosis in the elderly.

Authors:  Fleur Descoutures; Dominique Himbert; Laurent Lepage; Bernard Iung; Delphine Détaint; Didier Tchetche; Eric Brochet; Yves Castier; Jean-Pol Depoix; Patrick Nataf; Alec Vahanian
Journal:  Eur Heart J       Date:  2008-03-06       Impact factor: 29.983

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.