Literature DB >> 21747054

One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve.

Martyn Thomas1, Gerhard Schymik, Thomas Walther, Dominique Himbert, Thierry Lefèvre, Hendrik Treede, Holger Eggebrecht, Paolo Rubino, Antonio Colombo, Rüdiger Lange, Rebecca R Schwarz, Olaf Wendler.   

Abstract

BACKGROUND: Transcatheter aortic valve implantation was developed to provide a therapeutic option for patients considered to be ineligible for, and to mitigate mortality and morbidity associated with, high-risk surgical aortic valve replacement. METHODS AND
RESULTS: The Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry was designed to assess initial post commercial clinical transcatheter aortic valve implantation results of the Edwards SAPIEN valve in consecutive patients in Europe. Cohort 1 consists of 1038 patients enrolled at 32 centers. One-year outcomes are presented. Patients with the transapical approach (n=575) suffered more comorbidities than transfemoral patients (n=463) with a significantly higher logistic EuroSCORE (29% versus 25.8%; P=0.007). These groups are different; therefore, outcomes cannot be directly compared. Total Kaplan Meier 1-year survival was 76.1% overall, 72.1% for transapical and 81.1% for transfemoral patients, and 73.5% of surviving patients were in New York Heart Association (NYHA) class I or II at 1 year. Combined transapical and transfemoral causes of death were cardiac in 25.1%, noncardiac in 49.2%, and unknown in 25.7%. Pulmonary complications (23.9%), renal failure (12.5%), cancer (11.4%), and stroke (10.2%) were the most frequent noncardiac causes of death. Multivariable analysis identified logistic EuroSCORE, renal disease, liver disease, and smoking as variables with the highest hazard ratios for 1-year mortality whereas carotid artery stenosis, hyperlipidemia, and hypertension were associated with lower mortality.
CONCLUSION: The SOURCE Registry is the largest consecutively enrolled registry for transcatheter aortic valve implantation procedures. It demonstrates that with new transcatheter aortic techniques excellent 1-year survival in high-risk and inoperable patients is achievable and provides a benchmark against which future transcatheter aortic valve implantation cohorts and devices can be measured.

Entities:  

Mesh:

Year:  2011        PMID: 21747054     DOI: 10.1161/CIRCULATIONAHA.110.001545

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  93 in total

Review 1.  Current developments in transcatheter aortic valve implantation techniques.

Authors:  M Thielmann; P Kahlert; T Konorza; R Erbel; H Jakob; D Wendt
Journal:  Herz       Date:  2011-12       Impact factor: 1.443

Review 2.  Access and closure of the left ventricular apex: state of play.

Authors:  Johannes Amadeus Ziegelmueller; Rüdiger Lange; Sabine Bleiziffer
Journal:  J Thorac Dis       Date:  2015-09       Impact factor: 2.895

Review 3.  Acute kidney injury after transcatheter aortic valve implantation.

Authors:  Maximilian Scherner; Thorsten Wahlers
Journal:  J Thorac Dis       Date:  2015-09       Impact factor: 2.895

4.  Thromboinflammatory response and predictors of outcomes in patients undergoing transcatheter aortic valve replacement.

Authors:  Travis R Sexton; Eric L Wallace; Amy Chen; Richard J Charnigo; Hassan K Reda; Khaled M Ziada; John C Gurley; Susan S Smyth
Journal:  J Thromb Thrombolysis       Date:  2016-04       Impact factor: 2.300

Review 5.  Almanac 2013: novel non-coronary cardiac interventions.

Authors:  Pascal Meier; Olaf Franzen; Alexandra J Lansky
Journal:  Wien Klin Wochenschr       Date:  2013-12       Impact factor: 1.704

6.  Retrograde, transsubclavian implantation of a SAPIEN XT™ aortic valve prosthesis with the Edwards NovaFlex+™ system.

Authors:  J Blumenstein; A Van Linden; J Kempfert; Woung-Keung Kim; C Liebetrau; C Hamm; H Nef; T Walther; H Moellmann
Journal:  Clin Res Cardiol       Date:  2012-05-03       Impact factor: 5.460

7.  Transapical access closure: the TA PLUG device.

Authors:  Henriette Brinks; Fabian Nietlispach; Volkhard Göber; Lars Englberger; Peter Wenaweser; Bernhard Meier; Thierry Carrel; Christoph Huber
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-07-09

8.  Update of transcatheter valve treatment.

Authors:  Xian-bao Liu; Jian-an Wang
Journal:  J Zhejiang Univ Sci B       Date:  2013-08       Impact factor: 3.066

9.  3-year outcomes of self-expanding Corevalve prosthesis - The Italian Registry.

Authors:  Marco Barbanti; Gian Paolo Ussia; Stefano Cannata; Alessandra Giarratana; Carmelo Sgroi; Corrado Tamburino
Journal:  Ann Cardiothorac Surg       Date:  2012-07

Review 10.  Transcatheter aortic valve replacement: current application and future directions.

Authors:  Amir-Ali Fassa; Dominique Himbert; Alec Vahanian
Journal:  Curr Cardiol Rep       Date:  2013-04       Impact factor: 2.931

View more