Literature DB >> 22419651

Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation.

Oliver Husser1, Simon Rauch, Dierk H Endemann, Markus Resch, Julio Nunez, Vicente Bodi, Michael Hilker, Christof Schmid, Günter A J Riegger, Andreas Luchner, Christian Hengstenberg.   

Abstract

OBJECTIVES: To compare aortic annulus diameters obtained by 3D transesophageal echocardiography (TEE) with 2D-TEE and the impact on prosthesis size selection in transcatheter aortic valve implantation (TAVI).
BACKGROUND: In TAVI the aortic annulus diameter determines prosthesis size. The ideal modality for annulus assessment has not been defined yet.
METHODS: Annulus diameters in 2D-TEE (long-axis view) and in 3D-TEE (long-axis view in multiple-plane-reconstruction) were compared in consecutive patients with aortic stenosis screened for TAVI. Prosthesis size was selected according to industry guidelines, integrating data from 3D-TEE, angiography and computed tomography. The percentage of cases in which 2D-TEE and 3D-TEE correctly predicted final prosthesis size was calculated.
RESULTS: Forty-nine patients were studied (Age 80 ± 5, 39% male, logistic EuroScore 17 ± 11%). Annulus diameters from 2D- and 3D-TEE correlated (r = 0.808, P < 0.0001). Mean diameters were significantly larger on 3D- vs. 2D-TEE (23.4 ± 2.2 vs. 22.1 ± 2.6 mm, P < 0.001) with a mean difference of 1.2 mm (limits of agreement: -1.8 to 4.3). The interobserver variability of 2D- and 3D-TEE was 3.5 ± 5.6% and 0.9 ± 5.1%, respectively. Thirty-nine patients underwent TAVI (27 CoreValve™, 12 Edwards Sapien™). The procedure was successful in 37 (95%) patients. Postprocedural regurgitation was none or mild in 89% of the cases with no severe insufficiency. Final prosthesis size was correctly predicted by 2D-TEE in 67% while in 80% by 3D-TEE. Overall, 3D-TEE suggested a different prosthesis size in 26% of all cases compared to 2D-TEE.
CONCLUSIONS: Aortic annulus measurement by 3D-TEE yields significantly larger diameters than 2D-TEE. This impacts prosthesis size selection in a considerable percentage of cases.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22419651     DOI: 10.1002/ccd.23459

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  9 in total

Review 1.  Guidance of transcatheter aortic valve replacement by echocardiography.

Authors:  Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

2.  Comparison of transthoracic and transesophageal echocardiography for transcatheter aortic valve replacement sizing in high-risk patients.

Authors:  Henrik Fox; Katrin Hemmann; Ralf Lehmann
Journal:  J Echocardiogr       Date:  2019-10-19

3.  Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography.

Authors:  Cristina da Silva; Anders Sahlen; Reidar Winter; Magnus Bäck; Andreas Rück; Magnus Settergren; Aristomenis Manouras; Kambiz Shahgaldi
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-08       Impact factor: 2.357

4.  Patient selection for transcatheter aortic valve implantation: An interventional cardiology perspective.

Authors:  Darrren Mylotte; Giuseppe Martucci; Nicolo Piazza
Journal:  Ann Cardiothorac Surg       Date:  2012-07

5.  Imaging in Transcatheter Aortic Valve Replacement (TAVR): role of the radiologist.

Authors:  Diana E Litmanovich; Eduard Ghersin; David A Burke; Jeffrey Popma; Maryam Shahrzad; Alexander A Bankier
Journal:  Insights Imaging       Date:  2014-01-21

6.  Early outcomes of transcatheter aortic valve replacement in patients with severe aortic stenosis: single center experience.

Authors:  Engin Bozkurt; Telat Keleş; Tahir Durmaz; Murat Akçay; Cenk Sari; Hüseyin Ayhan; Nihal Akar Bayram; Abdullah Nabi Aslan; Serdal Baştuğ; Emine Bilen
Journal:  Postepy Kardiol Interwencyjnej       Date:  2014-06-26       Impact factor: 1.426

7.  Utility of conventional aortic root shot angiography for SAPIEN 3 prosthesis sizing in TAVI: feasibility and inter-reader variability.

Authors:  Laura Gansera; Bernhard Ulm; Peter Bramlage; Stephan Krapf; Frank Oertel; Tobias Mueller-Honold; Wolfgang von Scheidt; Christian Thilo
Journal:  Open Heart       Date:  2019-12-29

8.  Comparison of the effective orifice area of prosthetic mitral valves using two-dimensional versus three-dimensional transesophageal echocardiography.

Authors:  Lei Zhou; Hai-Yan Wei; Ya-Li Ge; Zheng-Nian Ding; Hong-Wei Shi
Journal:  J Int Med Res       Date:  2021-03       Impact factor: 1.671

9.  Transesophageal echocardiography measurements of aortic annulus diameter using biplane mode in patients undergoing transcatheter aortic valve implantation.

Authors:  Kambiz Shahgaldi; Cristina da Silva; Magnus Bäck; Andreas Rück; Aristomenis Manouras; Anders Sahlén
Journal:  Cardiovasc Ultrasound       Date:  2013-01-30       Impact factor: 2.062

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.