Literature DB >> 20117398

Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation.

David Messika-Zeitoun1, Jean-Michel Serfaty, Eric Brochet, Gregory Ducrocq, Laurent Lepage, Delphine Detaint, Fabien Hyafil, Dominique Himbert, Nicoletta Pasi, Jean-Pierre Laissy, Bernard Iung, Alec Vahanian.   

Abstract

OBJECTIVES: We sought to compare 3 methods of measurements of the aortic annulus, transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and multislice computed tomography (MSCT), and to evaluate their potential clinical impact on transcatheter aortic valve implantation (TAVI) strategy.
BACKGROUND: Exact measurement of the aortic annulus is critical for a patient's selection and successful implantation.
METHODS: Annulus diameter was measured using TTE, TEE, and MSCT in 45 consecutive patients with severe aortic stenosis referred for TAVI. The TAVI strategy (decision to implant and choice of the prosthesis' size) was based on manufacturer's recommendations (Edwards-Sapien prosthesis, Edwards Lifesciences, Inc., Irvine, California).
RESULTS: Correlations between methods were good but the difference between MSCT and TTE (1.22 +/- 1.3 mm) or TEE (1.52 +/- 1.1 mm) was larger than the difference between TTE and TEE (0.6 +/- 0.8 mm; p = 0.03 and p < 0.0001, respectively). Regarding TAVI strategy, agreement between TTE and TEE overall was good (kappa = 0.68), but TAVI strategy would have been different in 8 patients (17%). Agreement between MSCT and TTE or TEE was only modest (kappa = 0.28 and 0.27), and a decision based on MSCT measurements would have modified the TAVI strategy in a large number of patients (40% to 42%). Implantation, performed in 34 patients (76%) based on TEE measurements, was successful in all but 1 patient with grade 3/4 regurgitation.
CONCLUSIONS: In patients referred for TAVI, measurements of the aortic annulus using TTE, TEE, and MSCT were close but not identical, and the method used has important potential clinical implications on TAVI strategy. In the absence of a gold standard, a strategy based on TEE measurements provided good clinical results. Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20117398     DOI: 10.1016/j.jacc.2009.06.063

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  76 in total

Review 1.  Current developments in transcatheter aortic valve implantation techniques.

Authors:  M Thielmann; P Kahlert; T Konorza; R Erbel; H Jakob; D Wendt
Journal:  Herz       Date:  2011-12       Impact factor: 1.443

Review 2.  Multimodality imaging in interventional cardiology.

Authors:  Bas L van der Hoeven; Martin J Schalij; Victoria Delgado
Journal:  Nat Rev Cardiol       Date:  2012-02-14       Impact factor: 32.419

3.  Optimization of acquisition and contrast injection protocol for C-arm CT imaging in transcatheter aortic valve implantation: initial experience in a swine model.

Authors:  Uma D Numburi; Samir R Kapadia; Paul Schoenhagen; E Murat Tuzcu; Martin von Roden; Sandra S Halliburton
Journal:  Int J Cardiovasc Imaging       Date:  2012-06-20       Impact factor: 2.357

4.  Comparison of aortic root measurements in patients undergoing transapical aortic valve implantation (TA-AVI) using three-dimensional rotational angiography (3D-RA) and multislice computed tomography (MSCT): differences and variability.

Authors:  Lukas H J Lehmkuhl; Konstantin von Aspern; Borek Foldyna; Matthias Grothoff; Stefan Nitzsche; Joerg Kempfert; Ardawan Rastan; Axel Linke; Friedrich W Mohr; Alois Noettling; Thomas Walther; Matthias Gutberlet
Journal:  Int J Cardiovasc Imaging       Date:  2012-06-19       Impact factor: 2.357

5.  Successful repair of aortic annulus rupture during transcatheter aortic valve replacement using extracorporeal membrane oxygenation support.

Authors:  Smita I Negi; Jay Patel; Manish Patel; Pranav Loyalka; Biswajit Kar; Igor Gregoric
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-08-30

Review 6.  Advanced 3-D analysis, client-server systems, and cloud computing-Integration of cardiovascular imaging data into clinical workflows of transcatheter aortic valve replacement.

Authors:  Paul Schoenhagen; Mathis Zimmermann; Juergen Falkner
Journal:  Cardiovasc Diagn Ther       Date:  2013-06

Review 7.  Computed tomography in the evaluation for transcatheter aortic valve implantation (TAVI).

Authors:  Paul Schoenhagen; Jörg Hausleiter; Stephan Achenbach; Milind Y Desai; E Murat Tuzcu
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

8.  The clinical anatomy and pathology of the human arterial valves: implications for repair or replacement.

Authors:  Michael G Bateman; Alexander J Hill; Jason L Quill; Paul A Iaizzo
Journal:  J Cardiovasc Transl Res       Date:  2013-01-17       Impact factor: 4.132

Review 9.  [Echocardiography during transcatheter interventions. New developments].

Authors:  J Balzer
Journal:  Herz       Date:  2013-02       Impact factor: 1.443

10.  Practical update on imaging and transcatheter aortic valve implantation.

Authors:  Gisela Feltes; Iván J Núñez-Gil
Journal:  World J Cardiol       Date:  2015-04-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.