Literature DB >> 17665783

Pitfalls in determining knee alignment: a radiographic cadaver study.

R W Brouwer1, T S C Jakma, K H Brouwer, J A N Verhaar.   

Abstract

Full-length anteroposterior (AP) radiographs provide the basis for evaluating leg alignment. A cadaver study was performed to determine the effect of knee flexion and hip rotation on projected angles on full-length AP radiographs. The outcomes were verified mathematically. The results of the cadaver study were similar to the mathematical results. Flexion of the knee without rotation of the lower extremity has little effect on angles as projected on full-length AP radiographs. Rotation of the lower extremity without flexion of the knee also has little effect. Simultaneous flexion of the knee and rotation of the leg, however, cause large changes in projected angles. Full-length radiographs can be taken without fluoroscopic control as long as the knee can be fully extended. In flexion contracture, a full-length AP radiograph taken under lateral fluoroscopic control is necessary to obtain accurate determination of the mechanical axis.

Entities:  

Mesh:

Year:  2007        PMID: 17665783     DOI: 10.1055/s-0030-1248045

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  29 in total

Review 1.  Recent advances in medical imaging: anatomical and clinical applications.

Authors:  Bruno Grignon; Laurence Mainard; Matthieu Delion; Claude Hodez; Guillaume Oldrini
Journal:  Surg Radiol Anat       Date:  2012-05-29       Impact factor: 1.246

2.  Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique.

Authors:  Kilian Reising; Peter C Strohm; Oliver Hauschild; Hagen Schmal; Mohmed Khattab; Norbert P Südkamp; Philipp Niemeyer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-04       Impact factor: 4.342

3.  Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study.

Authors:  Mark Yaffe; Michael Luo; Nitin Goyal; Philip Chan; Anay Patel; Max Cayo; S David Stulberg
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-13       Impact factor: 2.924

4.  Agreement between radiological and computer navigation measurement of lower limb alignment.

Authors:  Julian Dexel; Stephan Kirschner; Klaus-Peter Günther; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-06       Impact factor: 4.342

5.  Radiographic and navigation measurements of TKA limb alignment do not correlate.

Authors:  Mark A Yaffe; Samuel S Koo; S David Stulberg
Journal:  Clin Orthop Relat Res       Date:  2008-11       Impact factor: 4.176

6.  Inconsistencies between navigation data and radiographs in total knee arthroplasty are system-dependent and affect coronal alignment.

Authors:  Alberto Carli; Ahmed Aoude; Avishai Reuven; Bogdan Matache; John Antoniou; David J Zukor
Journal:  Can J Surg       Date:  2014-10       Impact factor: 2.089

7.  Should we aim at undercorrection when doing a total knee arthroplasty?

Authors:  T Luyckx; F Vanhoorebeeck; J Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-07-24       Impact factor: 4.342

8.  Effect of local alignment on compartmental patterns of knee osteoarthritis.

Authors:  Fazel A Khan; Matthew F Koff; Nicolas O Noiseux; Kathie A Bernhardt; Megan M O'Byrne; Dirk R Larson; Kimberly K Amrami; Kenton R Kaufman
Journal:  J Bone Joint Surg Am       Date:  2008-09       Impact factor: 5.284

9.  Effect of foot rotation on the mechanical axis and correlation between knee and whole leg radiographs.

Authors:  Yong Seuk Lee; Beom Koo Lee; Seung Hoon Lee; Hong Gi Park; Deuk-Soo Jun; Do Hyun Moon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-01       Impact factor: 4.342

10.  Longitudinal shapes of the tibia and femur are unrelated and variable.

Authors:  Stephen M Howell; Kyle Kuznik; Maury L Hull; Robert A Siston
Journal:  Clin Orthop Relat Res       Date:  2009-07-22       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.