Literature DB >> 25046590

Selection and evaluation of optimal two-dimensional CAIPIRINHA kernels applied to time-resolved three-dimensional CE-MRA.

Paul T Weavers1, Eric A Borisch1, Stephen J Riederer1.   

Abstract

PURPOSE: To develop and validate a method for choosing the optimal two-dimensional CAIPIRINHA kernel for subtraction contrast-enhanced MR angiography (CE-MRA) and estimate the degree of image quality improvement versus that of some reference acceleration parameter set at R ≥ 8.
METHODS: A metric based on patient-specific coil calibration information was defined for evaluating optimality of CAIPIRINHA kernels as applied to subtraction CE-MRA. Evaluation in retrospective studies using archived coil calibration data from abdomen, calf, foot, and hand CE-MRA exams was accomplished with an evaluation metric comparing the geometry factor (g-factor) histograms. Prospective calf, foot, and hand CE-MRA studies were evaluated with vessel signal-to-noise ratio (SNR).
RESULTS: Retrospective studies show g-factor improvement for the selected CAIPIRINHA kernels was significant in the feet, moderate in the abdomen, and modest in the calves and hands. Prospective CE-MRA studies using optimal CAIPIRINHA show reduced noise amplification with identical acquisition time in studies of the feet, with minor improvements in the hands and calves.
CONCLUSION: A method for selection of the optimal CAIPIRINHA kernel for high (R ≥ 8) acceleration CE-MRA exams given a specific patient and receiver array was demonstrated. CAIPIRINHA optimization appears valuable in accelerated CE-MRA of the feet and to a lesser extent in the abdomen.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  CAIPIRINHA; acceleration; optimization; parallel imaging

Mesh:

Substances:

Year:  2014        PMID: 25046590      PMCID: PMC4298474          DOI: 10.1002/mrm.25366

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Clinical evaluation of CAIPIRINHA: comparison against a GRAPPA standard.

Authors:  Katherine L Wright; Michael W Harrell; John A Jesberger; Luis Landeras; Dean A Nakamoto; Smitha Thomas; Dominik Nickel; Randall Kroeker; Mark A Griswold; Vikas Gulani
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

3.  Contrast-enhanced MR angiography of the abdomen with highly accelerated acquisition techniques.

Authors:  Petrice M Mostardi; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Radiology       Date:  2011-09-07       Impact factor: 11.105

Review 4.  High temporal and spatial resolution 3D time-resolved contrast-enhanced magnetic resonance angiography of the hands and feet.

Authors:  Clifton R Haider; Stephen J Riederer; Eric A Borisch; James F Glockner; Roger C Grimm; Thomas C Hulshizer; Thanila A Macedo; Petrice M Mostardi; Phillip J Rossman; Terri J Vrtiska; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2011-07       Impact factor: 4.813

5.  Acceleration apportionment: a method of improved 2D SENSE acceleration applied to 3D contrast-enhanced MR angiography.

Authors:  Paul T Weavers; Eric A Borisch; Casey P Johnson; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

6.  CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE): a new technique for fast time-resolved dynamic 3-dimensional imaging of the abdomen with high spatial resolution.

Authors:  Henrik J Michaely; John N Morelli; Johannes Budjan; Philipp Riffel; Dominik Nickel; Randall Kroeker; Stefan O Schoenberg; Ulrike I Attenberger
Journal:  Invest Radiol       Date:  2013-08       Impact factor: 6.016

7.  Peripheral vasculature: high-temporal- and high-spatial-resolution three-dimensional contrast-enhanced MR angiography.

Authors:  Clifton R Haider; James F Glockner; Anthony W Stanson; Stephen J Riederer
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

8.  Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging.

Authors:  Philipp Riffel; Ulrike I Attenberger; Stephan Kannengiesser; Marcel D Nickel; Carolyn Arndt; Mathias Meyer; Stefan O Schoenberg; Henrik J Michaely
Journal:  Invest Radiol       Date:  2013-07       Impact factor: 6.016

9.  3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain.

Authors:  Clifton R Haider; Houchun Harry Hu; Norbert G Campeau; John Huston; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

10.  Ultrafast whole-body MR angiography with two-dimensional parallel imaging at 3.0 T: feasibility study.

Authors:  Michael Fenchel; Joerg Doering; Achim Seeger; Ulrich Kramer; Kilian Rittig; Bernhard Klumpp; Claus D Claussen; Stephan Miller
Journal:  Radiology       Date:  2008-11-10       Impact factor: 11.105

View more
  5 in total

Review 1.  Recent advances in parallel imaging for MRI.

Authors:  Jesse Hamilton; Dominique Franson; Nicole Seiberlich
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-05-02       Impact factor: 9.795

2.  On-the-Fly Adaptive ${k}$ -Space Sampling for Linear MRI Reconstruction Using Moment-Based Spectral Analysis.

Authors:  Evan Levine; Brian Hargreaves
Journal:  IEEE Trans Med Imaging       Date:  2018-02       Impact factor: 10.048

3.  Time-resolved contrast-enhanced MR angiography with single-echo Dixon fat suppression.

Authors:  Eric G Stinson; Joshua D Trzasko; Norbert G Campeau; James F Glockner; John Huston; Phillip M Young; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2018-02-27       Impact factor: 4.668

4.  Improved receiver arrays and optimized parallel imaging accelerations applied to time-resolved 3D fluoroscopically tracked peripheral runoff CE-MRA.

Authors:  Paul T Weavers; Eric A Borisch; Tom C Hulshizer; Phillip J Rossman; Phillip M Young; Casey P Johnson; Jessica McKay; Christopher C Cline; Stephen J Riederer
Journal:  Magn Reson Imaging       Date:  2015-10-31       Impact factor: 2.546

5.  A Cylindrical, Inner Volume Selecting 2D-T2-Prep Improves GRAPPA-Accelerated Image Quality in MRA of the Right Coronary Artery.

Authors:  Andrew J Coristine; Jerome Yerly; Matthias Stuber
Journal:  PLoS One       Date:  2016-10-13       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.