Literature DB >> 19001152

Ultrafast whole-body MR angiography with two-dimensional parallel imaging at 3.0 T: feasibility study.

Michael Fenchel1, Joerg Doering, Achim Seeger, Ulrich Kramer, Kilian Rittig, Bernhard Klumpp, Claus D Claussen, Stephan Miller.   

Abstract

The study was approved by the local ethics committee, and informed consent was provided by all participants prior to the examination. The aim of the study was to assess the feasibility of whole-body three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiography with parallel imaging in the phase- and section-encoding directions (ie, integrated parallel acquisition technique [iPAT(2); Siemens, Erlangen, Germany]) for all anatomic imaging stations in combination with a single injection of contrast material. Whole-body contrast-enhanced MR angiography was performed in 23 patients at 3.0 T. Images were evaluated by two independent observers for quality on a four-point scale (where a score of 1 indicated poor image quality and a score of 4, excellent image quality); signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated for representative vessel regions in each station. Mean image quality scores were 3.13 +/- 1.15 (standard deviation) and 3.17 +/- 1.14 for observers 1 and 2, respectively (kappa = 0.81). Signal intensity measurements revealed mean SNR values between 36.2 +/- 8.0 and 56.2 +/- 17.7 and mean CNR values between 29.0 +/- 7.4 and 48.2 +/- 15.7. The data suggest that contrast-enhanced MR angiography with iPAT(2) is feasible for whole-body applications and allows acquisition of 3D data sets with adequate spatial resolution within short measurement times, facilitating a single injection of contrast material. (c) RSNA, 2008.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19001152     DOI: 10.1148/radiol.2501080494

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Time-resolved bolus-chase MR angiography with real-time triggering of table motion.

Authors:  Casey P Johnson; Clifton R Haider; Eric A Borisch; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

2.  Selection and evaluation of optimal two-dimensional CAIPIRINHA kernels applied to time-resolved three-dimensional CE-MRA.

Authors:  Paul T Weavers; Eric A Borisch; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2014-07-15       Impact factor: 4.668

Review 3.  Magnetic resonance angiography: current status and future directions.

Authors:  Michael P Hartung; Thomas M Grist; Christopher J François
Journal:  J Cardiovasc Magn Reson       Date:  2011-03-09       Impact factor: 5.364

4.  Acceleration apportionment: a method of improved 2D SENSE acceleration applied to 3D contrast-enhanced MR angiography.

Authors:  Paul T Weavers; Eric A Borisch; Casey P Johnson; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

5.  Technical assessment of whole body angiography and cardiac function within a single MRI examination.

Authors:  S J Gandy; M Lambert; J J F Belch; I D Cavin; E Crowe; R Littleford; J A Macfarlane; S Z Matthew; P Martin; R S Nicholas; A D Struthers; F Sullivan; S A Waugh; R D White; J R Weir-McCall; J G Houston
Journal:  Clin Radiol       Date:  2015-03-16       Impact factor: 2.350

6.  Prediction of coronary artery disease by a systemic atherosclerosis score index derived from whole-body MR angiography.

Authors:  Stephanie Lehrke; Benjamin Egenlauf; Henning Steen; Dirk Lossnitzer; Grigorius Korosoglou; Constanze Merten; Boris T Ivandic; Evangelos Giannitsis; Hugo A Katus
Journal:  J Cardiovasc Magn Reson       Date:  2009-09-17       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.