Literature DB >> 23538886

CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE): a new technique for fast time-resolved dynamic 3-dimensional imaging of the abdomen with high spatial resolution.

Henrik J Michaely1, John N Morelli, Johannes Budjan, Philipp Riffel, Dominik Nickel, Randall Kroeker, Stefan O Schoenberg, Ulrike I Attenberger.   

Abstract

PURPOSE: The purpose of this study was to assess the feasibility and image quality of a novel, highly accelerated T1-weighted sequence for time-resolved imaging of the abdomen during the first pass of contrast media transit using controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) under sampling, view-sharing techniques, and Dixon water-fat separation (CAIPRINHA-Dixon-time-resolved imaging with interleaved stochastic trajectories-volumetric interpolated breath-hold examination [CDT-VIBE]).
MATERIALS AND METHODS: In this retrospective, institutional review board-approved study, 47 patients (median age, 62 years; 25 men, 22 women) scanned on a 3.0-T magnetic resonance system (Skyra; Siemens) were included. The CDT-VIBE (repetition time/echo time1/echo time2, 4.1/1.33/2.56 milliseconds; acquisition time, 29 seconds) was used in place of the standard arterial phase acquisition and started 15 seconds after the injection of 0.1 mmol/kg Gd-DOTA (Dotarem, Guerbet). Within 29 seconds, 14 high spatial resolution (1.2 × 1.2 × 3 mm) 3-dimensional data sets were acquired and reconstructed using view sharing (temporal resolution, 2.1 seconds). The CDT-VIBE images were evaluated independently by 2 blinded, experienced radiologists with regard to image quality and the number of hepatic arterial-dominant phases present on an ordinal 5-point scale (5, excellent; 1, nondiagnostic). Added diagnostic information with CDT-VIBE relative to portal venous phase VIBE was assessed.
RESULTS: In all patients, CDT-VIBE measurements were successfully acquired. The image quality was diagnostic in 46 of the 47 patients. Both readers assessed the highest image quality present in the data sets with a median score of 4 (range, 3-5 for both readers; κ, 0.789) and the worst image quality with a median score of 3 (range, 1-4 for both readers; κ, 0.689). With a range between 1 and 8 (median, 5), hepatic arterial-dominant data sets (of the 14 acquired) were obtained in each case. There was an added diagnostic value with CDT-VIBE in 10 of the 47 patients (21%).
CONCLUSIONS: The CDT-VIBE is a robust approach allowing, for the first time, dynamic imaging of the upper abdomen with high temporal resolution and preservation of high spatial resolution.

Entities:  

Mesh:

Year:  2013        PMID: 23538886     DOI: 10.1097/RLI.0b013e318289a70b

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  30 in total

Review 1.  [Modern magnetic resonance imaging of the liver].

Authors:  D M Hedderich; K Weiss; D Maintz; T Persigehl
Journal:  Radiologe       Date:  2015-12       Impact factor: 0.635

2.  MRI morphologic alterations after liver SBRT : Direct dose correlation with intermodal matching.

Authors:  Judit Boda-Heggemann; Ulrike Attenberger; Johannes Budjan; Anika Jahnke; Lennart Jahnke; Lena Vogel; Anna O Simeonova-Chergou; Carsten Herskind; Frederik Wenz; Frank Lohr
Journal:  Strahlenther Onkol       Date:  2016-07-08       Impact factor: 3.621

3.  Direct dose correlation of MRI morphologic alterations of healthy liver tissue after robotic liver SBRT.

Authors:  Judit Boda-Heggemann; Anika Jahnke; Mark K H Chan; Leila S Ghaderi Ardekani; Peter Hunold; Jost Philipp Schäfer; Stefan Huttenlocher; Stefan Wurster; Dirk Rades; Guido Hildebrandt; Frank Lohr; Jürgen Dunst; Frederik Wenz; Oliver Blanck
Journal:  Strahlenther Onkol       Date:  2018-02-05       Impact factor: 3.621

4.  Influence of scan duration on the estimation of pharmacokinetic parameters for breast lesions: a study based on CAIPIRINHA-Dixon-TWIST-VIBE technique.

Authors:  Wen Hao; Bin Zhao; Guangbin Wang; Cuiyan Wang; Hui Liu
Journal:  Eur Radiol       Date:  2014-10-17       Impact factor: 5.315

5.  Modified CAIPIRINHA-VIBE without view-sharing on gadoxetic acid-enhanced multi-arterial phase MR imaging for diagnosing hepatocellular carcinoma: comparison with the CAIPIRINHA-Dixon-TWIST-VIBE.

Authors:  Seung Baek Hong; Nam Kyung Lee; Suk Kim; Hyeong Il Seo; Hyun Sung Kim; Dong Uk Kim; Tae Un Kim; Hwa Seong Ryu
Journal:  Eur Radiol       Date:  2019-04-16       Impact factor: 5.315

Review 6.  [CT and MRI of the liver: when, what, why?]

Authors:  J Budjan; S O Schoenberg; U I Attenberger
Journal:  Radiologe       Date:  2017-05       Impact factor: 0.635

7.  CAIPIRINHA-VIBE and GRAPPA-VIBE for liver MRI at 1.5 T: a comparative in vivo patient study.

Authors:  Ajaykumar C Morani; Rafael A Vicens; Wei Wei; Shiva Gupta; Raghu Vikram; Aparna Balachandran; Brandy J Reed; Jingfei Ma; Aliya Qayyum; Janio Szklaruk
Journal:  J Comput Assist Tomogr       Date:  2015 Mar-Apr       Impact factor: 1.826

8.  Three-dimensional volumetric MRI with isotropic resolution: improved speed of acquisition, spatial resolution and assessment of lesion conspicuity in patients with recurrent soft tissue sarcoma.

Authors:  Shivani Ahlawat; Carol Morris; Laura M Fayad
Journal:  Skeletal Radiol       Date:  2016-02-20       Impact factor: 2.199

Review 9.  Recent advances in parallel imaging for MRI.

Authors:  Jesse Hamilton; Dominique Franson; Nicole Seiberlich
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-05-02       Impact factor: 9.795

10.  Autocalibrating motion-corrected wave-encoding for highly accelerated free-breathing abdominal MRI.

Authors:  Feiyu Chen; Tao Zhang; Joseph Y Cheng; Xinwei Shi; John M Pauly; Shreyas S Vasanawala
Journal:  Magn Reson Med       Date:  2016-12-09       Impact factor: 4.668

View more