Zhiyu Zhou1, Manman Gao2, Fuxin Wei2, Jiabi Liang3, Wenbin Deng4, Xuejun Dai2, Guangqian Zhou5, Xuenong Zou2.
Abstract
Hydrogel injection has been recently proposed as a novel therapy for disc degenerative diseases, with the potential to restore the spine motion and the intervertebral disc height. However, it remains unknown whether the new technique could also maintain the shock absorbing property of the treated intervertebral disc. In this study, 18 porcine lumbar bone-disc-bone specimens were collected and randomly divided into three groups: the normal with intact intervertebral discs, the mimic for the injection of disulfide cross-linked hyaluronan hydrogels following discectomy, and the control disc with discectomy only. In the static compression test, specimens in the mimic group exhibited displacements similar to those in the normal discs, whereas the control group showed a significantly larger displacement range in the first two steps (P < 0.05). With the frequency increasing, all specimens generally displayed an increasing storage modulus, decreasing loss modulus, and tanδ. At any frequency point, the control group exhibited the largest value in all the three parameters among three groups while the normal group was the lowest, with the mimic group being mostly close to the normal group. Therefore, the hydrogel injection into the intervertebral discs greatly restored their shock absorbing function, suggesting that the technique could serve as an effective approach to maintaining biomechanical properties of the degenerative intervertebral disc.Entities:
Mesh:
Substances:
Year: 2014 PMID: 25045680 PMCID: PMC4090528 DOI: 10.1155/2014/461724
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Figure 1MRI examining of bone-disc-bone specimens. (a) The discectomied discs injected with hydrogel (mimic group). (b) The normal discs (normal groups). (c) The discectomied discs (control group).
Figure 2(a) Procedures of the static compression test. (b) Displacement in each step of different groups in the static compression test (*P < 0.05, # P < 0.01).
Figure 3Results of the dynamic compression test. With the frequency increasing, the storage modulus increased significantly (P < 0.01) and both the loss modulus and tanδ decreased significantly (P < 0.01). (a) Storage modulus of control group was significantly higher than the other two groups (P < 0.01). (b) Loss modulus of control group was significantly higher than the other two groups (P < 0.01). (c) tanδ of control group was significantly higher than the other two groups (P < 0.01).