Literature DB >> 8534294

Preliminary results of an absorbable interference screw.

F A Barber1, B F Elrod, D A McGuire, L E Paulos.   

Abstract

A randomized, prospective multicenter comparison was done of a bioabsorbable interference screw (Bioscrew; Linvatec Corp, Largo, FL) made from poly L-lactic acid and a metal interference screw produced by the same company. Assignment was randomized by sealed envelopes. A total of 110 patients underwent arthroscopic patellar tendon autografts. A minimum 12 months follow-up is available on 85 patients (mean 19 months, range 12 to 33) including 42 with Bioscrews and 43 with metal screws. There were 56 male and 29 female patients. The average age was 29 years (16 to 50 years). Tourniquet times and associated surgical findings were similar for the two groups. Postoperative Tegner and Lysholm scores were not statistically different between the two groups. KT tests at 1 year showed an average 20-lb laxity of 1.8 mm for the Bioscrew and 1.2 mm for the metal screw groups. The average 1-year KT maximum manual side-to-side difference was 1.6 mm for Bioscrews and 1.6 mm for metal screws. A pivot shift was absent in 83% of Bioscrews and 90% of metal screws at follow-up. Six of 85 Bioscrews inserted (7%) broke on insertion (all were 7-mm diameter screws at the femoral site). No additional fixation was required in four cases. In two, the broken screw was replaced. No lytic bone changes or tunnel widening were found with any Bioscrew. One metal screw had tibial tunnel widening. No statistical difference was found between the Bioscrew and the metal screw groups. Short-term data support the conclusion that the Bioscrew is a reasonable alternative to metal interference screws.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8534294     DOI: 10.1016/0749-8063(95)90129-9

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  21 in total

1.  [Arthroscopic reconstruction of anterior cruciate ligament with press-fit technique].

Authors:  A M Halder
Journal:  Unfallchirurg       Date:  2010-08       Impact factor: 1.000

2.  Letter to the editor: Fibroxanthoma: a complication of a biodegradable screw.

Authors:  Thomas W Bauer
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

3.  Breakage of bioabsorbable femoral transfix screw after arthroscopic anterior cruciate ligament repair: a report of two cases.

Authors:  A Raviraj; Ashish Anand; K Santosh
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-02-04

4.  [ACL reconstruction with bone-patellar tendon-bone graft and proximal fixation with the EndoButton: a 2- to 5-year follow-up].

Authors:  K Tecklenburg; C Hoser; R Sailer; J Oberladstätter; C Fink
Journal:  Unfallchirurg       Date:  2005-09       Impact factor: 1.000

5.  Comparison of bioabsorbable interference screws and posts for distal fixation in anterior cruciate ligament reconstruction.

Authors:  Krzysztof Gaweda; Jacek Walawski; Robert Wegłowski; Wojciech Krzyzanowski
Journal:  Int Orthop       Date:  2007-12-07       Impact factor: 3.075

6.  A Comparison of Functional Outcomes After Metallic and Bioabsorbable Interference Screw Fixations in Arthroscopic ACL Reconstructions.

Authors:  Atmananda S Hegde; Deepak K Rai; Antony J Kannampilly
Journal:  J Clin Diagn Res       Date:  2014-04-15

7.  Foreign body reaction to a bioabsorbable interference screw after anterior cruciate ligament reconstruction.

Authors:  Muhammad Umar; Nadeem Baqai; Christopher Peck
Journal:  BMJ Case Rep       Date:  2009-02-27

Review 8.  Graft fixation alternatives in anterior cruciate ligament reconstruction.

Authors:  Bernardino Saccomanni
Journal:  Musculoskelet Surg       Date:  2011-05-03

9.  Meta-analysis comparing bioabsorbable versus metal interference screw for adverse and clinical outcomes in anterior cruciate ligament reconstruction.

Authors:  Pat Laupattarakasem; Malinee Laopaiboon; Weerachai Kosuwon; Wiroon Laupattarakasem
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-14       Impact factor: 4.342

Review 10.  Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction.

Authors:  Pedro Debieux; Carlos E S Franciozi; Mário Lenza; Marcel Jun Tamaoki; Robert A Magnussen; Flávio Faloppa; João Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2016-07-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.