Adverse tissue reactions to bioabsorbable fixation devices.

O M Böstman1, H K Pihlajamäki.   

Abstract

Among 2528 patients operated on using pins, rods, bolts, and screws made of polyglycolic acid or polylactic acid, 108 (4.3%) were affected by a clinically significant local inflammatory, sterile tissue reaction. The three most common indications for the use of these fixation devices were a displaced malleolar fracture, a chevron osteotomy for hallux valgus, and a displaced fracture of the radial head. In 107 patients, the reaction was elicited by a polyglycolic acid implant, and in one patient by a polylactic acid implant. The incidences were 5.3% (107 of 2037) and 0.2% (one of 491), respectively. The adverse tissue responses to polyglycolic acid were seen 11 weeks after the operation, on average, whereas the reaction to polylactic acid occurred 4.3 years after fixation of an ankle fracture. The mild reactions consisted of a painful erythematous papule of a few weeks' duration. Those of medium severity had a sinus that discharged remnants of the implant for up to 6 months. In the patients affected by severe reactions, extensive osteolytic lesions developed at the implant tracks. The histopathologic picture was that of a nonspecific foreign body reaction. In four patients with vigorous reactions, an arthrodesis of the wrist or ankle later was necessary because of severe osteoarthritis. Several markers of increased risk of the occurrence of a foreign body reaction were found. These included a poorly vascularized bone section such as scaphoid, use of a quinone dye as an additive in the polymer, and an implant geometry with large surface area (screw versus pin or rod). For polyglycolic acid implants, the risk of an adverse tissue response in a given clinical situation can be estimated from the findings of this study. For slow degrading polymers like polylactic acid, however, the ultimate biocompatibility still is unsettled, and additional clinical research with long followup is required.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10693569

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  75 in total

1.  Is the etiology of pretibial cyst formation after absorbable interference screw use related to a foreign body reaction?

Authors:  Guillem Gonzalez-Lomas; Ryan T Cassilly; Fabrizio Remotti; William N Levine
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

2.  Letter to the editor: Fibroxanthoma: a complication of a biodegradable screw.

Authors:  Thomas W Bauer
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

3.  CALAXO osteoconductive interference screw: the value of postmarket surveillance.

Authors:  Charles L Cox; Kelly C Homlar; James L Carey; Kurt P Spindler
Journal:  J Surg Orthop Adv       Date:  2010

4.  Broken Delta interference screw after ACL reconstruction: a report of two cases.

Authors:  S M Bollen; H van der Hoeven
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-03-24       Impact factor: 4.342

Review 5.  Multimodality imaging of the postoperative shoulder.

Authors:  Klaus Woertler
Journal:  Eur Radiol       Date:  2007-05-22       Impact factor: 5.315

6.  Multilayer polypeptide nanoscale coatings incorporating IL-12 for the prevention of biomedical device-associated infections.

Authors:  Bingyun Li; Bingbing Jiang; Brandon M Boyce; Brock A Lindsey
Journal:  Biomaterials       Date:  2009-02-12       Impact factor: 12.479

7.  Assessment of essential characteristics of two different scaffolds for tendon in situ regeneration.

Authors:  Markus U Wagenhäuser; Matthias F Pietschmann; Denitsa Docheva; Mehmet F Gülecyüz; Volkmar Jansson; Peter E Müller
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-04       Impact factor: 4.342

8.  Delayed foreign-body reaction to absorbable implants in metacarpal fracture treatment.

Authors:  Panagiotis K Givissis; Stavros I Stavridis; Panayiotis J Papagelopoulos; Petros D Antonarakos; Anastasios G Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-05-15       Impact factor: 4.176

9.  Foreign-Body Reaction and Osteolysis in Dorsal Lunate Dislocation Repair With Bioabsorbable Suture Anchor.

Authors:  Ezequiel Ernesto Zaidenberg; Pablo Roitman; Gerardo Luis Gallucci; Jorge Guillermo Boretto; Pablo De Carli
Journal:  Hand (N Y)       Date:  2016-02-10

10.  Potency of double-layered poly L-lactic acid scaffold in tissue engineering of tendon tissue.

Authors:  Atsuyuki Inui; Takeshi Kokubu; Takeshi Makino; Issei Nagura; Narikazu Toyokawa; Ryosuke Sakata; Masaru Kotera; Takashi Nishino; Hiroyuki Fujioka; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2009-12-05       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.