Literature DB >> 11071612

Bioscrew fixation of patellar tendon autografts.

F A Barber1, B F Elrod, D A McGuire, L E Paulos.   

Abstract

Biodegradable interference screw fixation was studied using patellar tendon autografts in a randomized, prospective multicenter comparison of the PLLA Bioscrew and a metal interference screw. sixty-eight of 114 (60%) patients (34 Bioscrew and 34 metal screw) enrolled were available for follow up an average of 35 months after surgery (range 24-65). There were 42 males and 26 females with an average age of 29 years (16-50). Tourniquet times and associated surgical findings were similar for the two groups. Postoperative KT, Tegner, and Lysholm scores were not statistically different between the two groups. Average follow up KT maximum manual side-to-side difference was 0.9 mm for Bioscrews and 1.4 mm for metal screws. Postoperative Lachman and pivot shift testing were equivalent for the two groups. Other than six of the 7 mm Bioscrews breaking during insertion in the femoral tunnel, there were no problems related to the PLLA implants. No statistical difference was found between the Bioscrew and the metal screw groups, and there were no osteolytic or other reactive bone changes observed associated with the PLLA Bioscrew. These data indicate that the PLLA Bioscrew functions reliably as an interference fixation screw for patellar tendon autografts.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11071612     DOI: 10.1016/s0142-9612(00)00130-7

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  6 in total

Review 1.  Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction.

Authors:  M H Baums; B A Zelle; W Schultz; T Ernstberger; H-M Klinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-02-15       Impact factor: 4.342

2.  Autologous patellar tendon and quadrupled hamstring grafts in anterior cruciate ligament reconstruction: a prospective randomized multicenter review of different fixation methods.

Authors:  Jon Olav Drogset; Torbjørn Strand; Gisle Uppheim; Bjørn Odegård; Asbjørn Bøe; Torbjørn Grøntvedt
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-12-03       Impact factor: 4.342

3.  A Comparison of Functional Outcomes After Metallic and Bioabsorbable Interference Screw Fixations in Arthroscopic ACL Reconstructions.

Authors:  Atmananda S Hegde; Deepak K Rai; Antony J Kannampilly
Journal:  J Clin Diagn Res       Date:  2014-04-15

Review 4.  Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction.

Authors:  Pedro Debieux; Carlos E S Franciozi; Mário Lenza; Marcel Jun Tamaoki; Robert A Magnussen; Flávio Faloppa; João Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2016-07-24

5.  A prospective randomized study of ACL-reconstructions using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws.

Authors:  Jon Olav Drogset; Lene Granrud Straume; Ingrid Bjørkmo; Gunnar Myhr
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-14       Impact factor: 4.342

6.  Detached femoral bone plug following anterior cruciate ligament repair.

Authors:  Michael L Richardson; Christopher J Wahl
Journal:  Radiol Case Rep       Date:  2015-11-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.