Literature DB >> 24943245

Single-ring ablation compared with standard circumferential pulmonary vein isolation using remote magnetic catheter navigation.

Christian Sohns1, Leonard Bergau, Joachim Seegers, Lars Lüthje, Dirk Vollmann, Markus Zabel.   

Abstract

PURPOSE: In ablation of atrial fibrillation, the single-ring method aims for isolation of the posterior wall of the left atrium (LA) including the pulmonary veins (PVs) but avoiding posterior LA lesions. The aim of this randomized prospective study was to evaluate safety and efficacy of remote magnetic navigation (RMN)-guided single-ring ablation strategy as compared to standard RMN-guided circumferential PV ablation (PVA).
METHODS: Eighty consecutive patients undergoing PVA were enrolled prospectively and randomized equally into two study groups. RMN using the Stereotaxis system and open-irrigated 3.5-mm ablation catheters were used with a 3D mapping system in all procedures. Forty patients underwent RMN-guided single-ring ablation, and 40 patients received RMN-guided circumferential PVA.
RESULTS: In the circumferential group, 3.3 ± 1.1 PVs were successfully isolated at the end of the procedure as compared to 3.1 ± 1.3 in the single-ring (box) group (p=0.38). All patients in the box group required additional posterior lesions in order to achieve electrical isolation of the PVs. Single-ring ablation was associated with longer procedure duration (p=0.01) and ablation time (p=0.001). After a single procedure, the proportion of patients free of any atrial tachycardia (AT)/atrial fibrillation (AF) episode at 12-month follow-up was 57 % in the box group and 58 % in the circ group. Using RMN, only minor complications have been observed.
CONCLUSIONS: RMN-guided single-ring PVA provides comparable acute and long-term success rates as compared to RMN-guided circumferential PVA but requires additional posterior lesions to achieve PV isolation and increased procedure and ablation time. Procedural complication rates are low when using RMN.

Entities:  

Mesh:

Year:  2014        PMID: 24943245     DOI: 10.1007/s10840-014-9915-x

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  27 in total

1.  Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.

Authors:  Riccardo Cappato; Hugh Calkins; Shih-Ann Chen; Wyn Davies; Yoshito Iesaka; Jonathan Kalman; You-Ho Kim; George Klein; Andrea Natale; Douglas Packer; Allan Skanes; Federico Ambrogi; Elia Biganzoli
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12-07

2.  Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation.

Authors:  K R Julian Chun; Erik Wissner; Buelent Koektuerk; Melanie Konstantinidou; Boris Schmidt; Thomas Zerm; Andreas Metzner; Roland Tilz; Sigrid Boczor; Alexander Fuernkranz; Feifan Ouyang; Karl-Heinz Kuck
Journal:  Circ Arrhythm Electrophysiol       Date:  2010-07-07

3.  Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.

Authors:  Daniel Steven; Vivek Y Reddy; Keiichi Inada; Kurt C Roberts-Thomson; Jens Seiler; William G Stevenson; Gregory F Michaud
Journal:  Heart Rhythm       Date:  2009-11-12       Impact factor: 6.343

4.  Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: a case-control study.

Authors:  Arash Arya; Ruzbeh Zaker-Shahrak; Phillip Sommer; Andreas Bollmann; Ulrike Wetzel; Thomas Gaspar; Sergio Richter; Daniela Husser; Christopher Piorkowski; Gerhard Hindricks
Journal:  Europace       Date:  2010-10-06       Impact factor: 5.214

5.  Remote magnetic navigation: human experience in pulmonary vein ablation.

Authors:  Luigi Di Biase; Tamer S Fahmy; Dimpi Patel; Rong Bai; Kenneth Civello; Oussama M Wazni; Mohamed Kanj; Claude S Elayi; Chi Keong Ching; Mohamed Khan; Lucie Popova; Robert A Schweikert; Jennifer E Cummings; J David Burkhardt; David O Martin; Mandeep Bhargava; Thomas Dresing; Walid Saliba; Mauricio Arruda; Andrea Natale
Journal:  J Am Coll Cardiol       Date:  2007-08-13       Impact factor: 24.094

6.  Robotic magnetic navigation for atrial fibrillation ablation.

Authors:  Carlo Pappone; Gabriele Vicedomini; Francesco Manguso; Filippo Gugliotta; Patrizio Mazzone; Simone Gulletta; Nicoleta Sora; Simone Sala; Alessandra Marzi; Giuseppe Augello; Laura Livolsi; Andreina Santagostino; Vincenzo Santinelli
Journal:  J Am Coll Cardiol       Date:  2006-03-15       Impact factor: 24.094

7.  Pulmonary vein isolation after circumferential pulmonary vein ablation: comparison between Lasso and three-dimensional electroanatomical assessment of complete electrical disconnection.

Authors:  Giuseppe Augello; Gabriele Vicedomini; Massimo Saviano; Simonetta Crisa; Patrizio Mazzone; Ombretta Ornago; Francesca Zuffada; Vincenzo Santinelli; Carlo Pappone
Journal:  Heart Rhythm       Date:  2009-09-06       Impact factor: 6.343

8.  Clinical implications of reconnection between the left atrium and isolated pulmonary veins provoked by adenosine triphosphate after extensive encircling pulmonary vein isolation.

Authors:  Hitoshi Hachiya; Kenzo Hirao; Atsushi Takahashi; Yasutoshi Nagata; Kenji Suzuki; Shingo Maeda; Takeshi Sasaki; Mihoko Kawabata; Mitsuaki Isobe; Yoshito Iesaka
Journal:  J Cardiovasc Electrophysiol       Date:  2007-02-07

9.  Left atrial posterior wall isolation does not improve the outcome of circumferential pulmonary vein ablation for atrial fibrillation: a prospective randomized study.

Authors:  David Tamborero; Lluís Mont; Antonio Berruezo; Maria Matiello; Begoña Benito; Marta Sitges; Barbara Vidal; Teresa M de Caralt; Rosario J Perea; Radu Vatasescu; Josep Brugada
Journal:  Circ Arrhythm Electrophysiol       Date:  2008-12-03

10.  Catheter-induced linear lesions in the left atrium in patients with atrial fibrillation: an electroanatomic study.

Authors:  Sabine Ernst; Feifan Ouyang; Felix Löber; Matthias Antz; Karl-Heinz Kuck
Journal:  J Am Coll Cardiol       Date:  2003-10-01       Impact factor: 24.094

View more
  3 in total

1.  Significant reduction in procedure duration in remote magnetic-guided catheter ablation of atrial fibrillation using the third-generation magnetic navigation system.

Authors:  Tilman Maurer; Christian Sohns; Sebastian Deiss; Laura Rottner; Peter Wohlmuth; Bruno Reißmann; Christian H Heeger; Christine Lemes; Johannes Riedl; Francesco Santoro; Shibu Mathew; Andreas Metzner; Feifan Ouyang; Karl-Heinz Kuck; Erik Wissner
Journal:  J Interv Card Electrophysiol       Date:  2017-06-10       Impact factor: 1.900

2.  Comparisons of efficacy, safety, and recurrence risk factors of paroxysmal and persistent atrial fibrillation catheter ablation using robotic magnetic navigation system.

Authors:  Xiao-Xi Zhao; Ku-Lin Li; Ru-Xing Wang; Jie Zheng; Xiao-Yu Liu; Shi-Peng Dang; Zhi-Ming Yu; Chang-Ying Zhang; Xiang-Jun Yang
Journal:  Clin Cardiol       Date:  2019-03-15       Impact factor: 2.882

3.  Challenges and Outcomes of Posterior Wall Isolation for Ablation of Atrial Fibrillation.

Authors:  Prabhat Kumar; Ayotunde M Bamimore; Jennifer D Schwartz; Eugene H Chung; Anil K Gehi; Andy C Kiser; James P Hummel; J Paul Mounsey
Journal:  J Am Heart Assoc       Date:  2016-09-23       Impact factor: 5.501

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.