Literature DB >> 17719473

Remote magnetic navigation: human experience in pulmonary vein ablation.

Luigi Di Biase1, Tamer S Fahmy, Dimpi Patel, Rong Bai, Kenneth Civello, Oussama M Wazni, Mohamed Kanj, Claude S Elayi, Chi Keong Ching, Mohamed Khan, Lucie Popova, Robert A Schweikert, Jennifer E Cummings, J David Burkhardt, David O Martin, Mandeep Bhargava, Thomas Dresing, Walid Saliba, Mauricio Arruda, Andrea Natale.   

Abstract

OBJECTIVES: We aimed at assessing the feasibility and efficacy of remote magnetic navigation (MN) and ablation in patients with atrial fibrillation (AF).
BACKGROUND: This novel MN system could facilitate standardization of the procedures, reducing the importance of the operator skill.
METHODS: After becoming familiar with the system in 48 previous patients, 45 consecutive patients with AF were considered for ablation using the Niobe II remote magnetic system (Stereotaxis, St. Louis, Missouri) in a stepwise approach: circumferential pulmonary vein ablation (CPVA), pulmonary vein antrum isolation (PVAI), and, if failed, PVAI using the conventional approach. Remote navigation was done using the coordinate or the wand approach. Ablation end point was electrical disconnection of the pulmonary veins (PVs).
RESULTS: Using the coordinate approach, the target location was reached in only 60% of the sites, whereas by using the wand approach 100% of the sites could be reached. After step 2 ablation, only 1 PV in 4 patients (8%) could be electrically isolated. Charring on the ablation catheter tip was seen in 15 (33%) of the cases. In 23 patients, all PVs were isolated with the conventional thermocool catheter, and in 22 patients only the right PVs were isolated with the conventional catheter. After a mean follow-up period of 11 +/- 2 months, recurrence was seen in 5 patients (22%) with complete PVAI and in 20 patients (90%) with incomplete PVAI.
CONCLUSIONS: Remote navigation using a magnetic system is a feasible technique. With the present catheter technology, effective lesions cannot be achieved in most cases. This appears to impact the cure rate of AF patients.

Entities:  

Mesh:

Year:  2007        PMID: 17719473     DOI: 10.1016/j.jacc.2007.05.023

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  32 in total

Review 1.  The art of war: Innate and adaptive immune responses.

Authors:  P W Dempsey; S A Vaidya; G Cheng
Journal:  Cell Mol Life Sci       Date:  2003-12       Impact factor: 9.261

Review 2.  Magnetic and robotic navigation for catheter ablation: "joystick ablation".

Authors:  Sabine Ernst
Journal:  J Interv Card Electrophysiol       Date:  2008-06-07       Impact factor: 1.900

Review 3.  Catheter ablation - new developments in robotics.

Authors:  K R Julian Chun; Boris Schmidt; Bülent Köktürk; Roland Tilz; Alexander Fürnkranz; Melanie Konstantinidou; Erik Wissner; Andreas Metzner; Feifan Ouyang; Karl-Heinz Kuck
Journal:  Herz       Date:  2008-12       Impact factor: 1.443

Review 4.  Irrigated-Tip Magnetic Catheter Ablation Of AF: ALong-Term Prospective Study In 130 Patients.

Authors:  Julian Chun
Journal:  J Atr Fibrillation       Date:  2011-07-15

5.  Magnetically guided irrigated gold-tip catheter ablation of persistent atrial fibrillation--techniques, procedural parameters and outcome.

Authors:  Bogdan Muntean; Klaus-Jürgen Gutleben; Johannes Heintze; Jürgen Vogt; Dieter Horstkotte; Georg Nölker
Journal:  J Interv Card Electrophysiol       Date:  2012-05-24       Impact factor: 1.900

Review 6.  Role of Remote Navigation Systems in AF Ablation.

Authors:  Boris Schmidt; Britta Schulte-Hahn; Bernd Nowak; Verena Windhorst; Verena Windhorst; Kyoung Ryul Julian Chun
Journal:  J Atr Fibrillation       Date:  2011-02-22

Review 7.  Differences In Tissue Injury and Ablation Outcomes In Atrial Fibrillation Patients - Manual versus Robotic Catheters.

Authors:  Georg Nölker; Dieter Horstkotte; Klaus Jürgen Gutleben
Journal:  J Atr Fibrillation       Date:  2013-08-31

8.  Recurrence of atrial fibrillation correlates with the extent of post-procedural late gadolinium enhancement: a pilot study.

Authors:  Dana C Peters; John V Wylie; Thomas H Hauser; Reza Nezafat; Yuchi Han; Jeong Joo Woo; Jason Taclas; Kraig V Kissinger; Beth Goddu; Mark E Josephson; Warren J Manning
Journal:  JACC Cardiovasc Imaging       Date:  2009-03

9.  Mapping and ablation of ventricular arrhythmias with magnetic navigation: comparison between 4- and 8-mm catheter tips.

Authors:  Luigi Di Biase; J David Burkhardt; Dhanunjaya Lakkireddy; Jayasree Pillarisetti; Esam Nuri Baryun; Mazda Biria; Rodney Horton; Javier Sanchez; G Joseph Gallinghouse; Shane Bailey; Salwa Beheiry; Richard Hongo; Steven Hao; Gery Tomassoni; Andrea Natale
Journal:  J Interv Card Electrophysiol       Date:  2009-07-29       Impact factor: 1.900

10.  Catheter ablation of atrial fibrillation guided by a 3D electroanatomical mapping system: a 2-year follow-up study from the Italian Registry On NavX Atrial Fibrillation ablation procedures (IRON-AF).

Authors:  Giovanni B Forleo; Giuseppe De Martino; Massimo Mantica; Endrj Menardi; Nicola Trevisi; Massimiliano Faustino; Carmine Muto; Francesco Perna; Matteo Santamaria; Claudio Pandozi; Augusto Pappalardo; Carmine Mancusi; Enrico Romano; Paolo Della Bella; Claudio Tondo
Journal:  J Interv Card Electrophysiol       Date:  2013-02-10       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.