Literature DB >> 24939638

Fixation and wear with a contemporary acetabular component and cross-linked polyethylene at minimum 10-year follow-up.

Nicholas A Bedard1, John J Callaghan2, Michael D Stefl3, Tyler J Willman1, Steve S Liu1, Devon D Goetz4.   

Abstract

UNLABELLED: Long term total hip arthroplasty follow-up has demonstrated bearing surface wear and failure of fixation as the major modes of failure. The purpose of this study was to evaluate the minimum 10year results of a third generation cementless acetabular component using moderately cross-linked polyethylene liners. 150 primary THAs were evaluated clinically for need for revision and activity evaluated using accelerometers, WOMAC, Tegner and UCLA activity-level scores. Radiographs were evaluated for wear, osteolysis and loosening. We compared this cohort to three of our previously reported cohorts. The only revision was unrelated to liner wear and all acetabular components were bone ingrown. There were no cases of acetabular osteolysis and one case of femoral osteolysis. Average steps per year were 1.59 million. Mean steady state wear rate averaged 0.04mm/year. At 10-years, excellent fixation and low wear were demonstrated using a cementless acetabular construct and moderately cross-linked polyethylene liner. LEVEL OF EVIDENCE: Therapeutic study, Level III (retrospective comparative study-prospective cohort with historical control).
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  activity level; cementless acetabular component; cross-linked polyethylene; outcomes; wear

Mesh:

Substances:

Year:  2014        PMID: 24939638     DOI: 10.1016/j.arth.2014.05.008

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene.

Authors:  Robert H Hopper; Henry Ho; Supatra Sritulanondha; Ann C Williams; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

2.  Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.

Authors:  Kevin L Garvin; Tyler C White; Anand Dusad; Curtis W Hartman; John Martell
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

3.  Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles.

Authors:  Yufei Yan; Hao Chen; Jianmin Feng; Kaizhe Chen; Kaidi Zhou; Weixiang Hong; Yi Wang; Zhihong Liu; Jiong Zhang; Qingming Yang; Lei Guo; Chuan He
Journal:  Int Orthop       Date:  2016-05-13       Impact factor: 3.075

4.  Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings.

Authors:  Murat Ali; Mazen Al-Hajjar; Susan Partridge; Sophie Williams; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2016-05       Impact factor: 1.617

5.  Acetabular Liner Dissociation: A Comparative Study of Two Contemporary Uncemented Acetabular Components.

Authors:  David P Gwynne-Jones; Adeel Memon
Journal:  Arthroplast Today       Date:  2020-06-12

6.  Different wear in two highly cross-linked polyethylene liners in THA: wear analysis with EBRA.

Authors:  D Dammerer; A Keiler; D Putzer; F Lenze; M Liebensteiner; M Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-04       Impact factor: 3.067

7.  An Incognizant Glitch-pinnacle Polyliner Dissociation: A Case Report.

Authors:  Ratnakar V; Aditya P Apte; Ashok Raju Gottemukkala; Adarsh Annapareddy; A V Gurava Reddy
Journal:  J Orthop Case Rep       Date:  2021-11

8.  Visual intraoperative estimation of cup and stem position is not reliable in minimally invasive hip arthroplasty.

Authors:  Michael Woerner; Ernst Sendtner; Robert Springorum; Benjamin Craiovan; Michael Worlicek; Tobias Renkawitz; Joachim Grifka; Markus Weber
Journal:  Acta Orthop       Date:  2016-02-05       Impact factor: 3.717

9.  Survivorship of a modular acetabular cup system: medium- to long-term follow-up.

Authors:  Kirk Kindsfater; Jim Lesko
Journal:  Arthroplast Today       Date:  2017-08-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.