Literature DB >> 26513015

Real-time Cherenkov emission portal imaging during CyberKnife® radiotherapy.

Yiannis Roussakis1, Rongxiao Zhang, Geoff Heyes, Gareth Webster, Suzannah Mason, Stuart Green, Brian Pogue, Hamid Dehghani.   

Abstract

The feasibility of real-time portal imaging during radiation therapy, through the Cherenkov emission (CE) effect is investigated via a medical linear accelerator (CyberKnife(®)) irradiating a partially-filled water tank with a 60 mm circular beam. A graticule of lead/plywood and a number of tissue equivalent materials were alternatively placed at the beam entrance face while the induced CE at the exit face was imaged using a gated electron-multiplying-intensified-charged-coupled device (emICCD) for both stationary and dynamic scenarios. This was replicated on an Elekta Synergy(®) linear accelerator with portal images acquired using the iViewGT(™) system. Profiles across the acquired portal images were analysed to reveal the potential resolution and contrast limits of this novel CE based portal imaging technique and compared against the current standard. The CE resolution study revealed that using the lead/plywood graticule, separations down to 3.4  ±  0.5 mm can be resolved. A 28 mm thick tissue-equivalent rod with electron density of 1.69 relative to water demonstrated a CE contrast of 15% through air and 14% through water sections, as compared to a corresponding contrast of 19% and 12% using the iViewGT(™) system. For dynamic scenarios, video rate imaging with 30 frames per second was achieved. It is demonstrated that CE-based portal imaging is feasible to identify both stationary and dynamic objects within a CyberKnife(®) radiotherapy treatment field.

Entities:  

Mesh:

Year:  2015        PMID: 26513015      PMCID: PMC4647064          DOI: 10.1088/0031-9155/60/22/N419

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam.

Authors:  Rongxiao Zhang; Adam K Glaser; David J Gladstone; Colleen J Fox; Brian W Pogue
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

2.  Real-time in vivo Cherenkoscopy imaging during external beam radiation therapy.

Authors:  Rongxiao Zhang; David J Gladstone; Lesley A Jarvis; Rendall R Strawbridge; P Jack Hoopes; Oscar D Friedman; Adam K Glaser; Brian W Pogue
Journal:  J Biomed Opt       Date:  2013-11       Impact factor: 3.170

3.  The physics of Cerenkov light production during proton therapy.

Authors:  Y Helo; A Kacperek; I Rosenberg; G Royle; A P Gibson
Journal:  Phys Med Biol       Date:  2014-11-03       Impact factor: 3.609

4.  Projection imaging of photon beams by the Čerenkov effect.

Authors:  Adam K Glaser; Scott C Davis; David M McClatchy; Rongxiao Zhang; Brian W Pogue; David J Gladstone
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  Three-dimensional Čerenkov tomography of energy deposition from ionizing radiation beams.

Authors:  Adam K Glaser; William H A Voigt; Scott C Davis; Rongxiao Zhang; David J Gladstone; Brian W Pogue
Journal:  Opt Lett       Date:  2013-03-01       Impact factor: 3.776

6.  Cherenkov video imaging allows for the first visualization of radiation therapy in real time.

Authors:  Lesley A Jarvis; Rongxiao Zhang; David J Gladstone; Shudong Jiang; Whitney Hitchcock; Oscar D Friedman; Adam K Glaser; Michael Jermyn; Brian W Pogue
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-28       Impact factor: 7.038

7.  Imaging Cerenkov emission as a quality assurance tool in electron radiotherapy.

Authors:  Yusuf Helo; Ivan Rosenberg; Derek D'Souza; Lindsay Macdonald; Robert Speller; Gary Royle; Adam Gibson
Journal:  Phys Med Biol       Date:  2014-04-02       Impact factor: 3.609

8.  Optical dosimetry of radiotherapy beams using Cherenkov radiation: the relationship between light emission and dose.

Authors:  Adam K Glaser; Rongxiao Zhang; David J Gladstone; Brian W Pogue
Journal:  Phys Med Biol       Date:  2014-06-18       Impact factor: 3.609

9.  Superficial dosimetry imaging of Čerenkov emission in electron beam radiotherapy of phantoms.

Authors:  Rongxiao Zhang; Colleen J Fox; Adam K Glaser; David J Gladstone; Brian W Pogue
Journal:  Phys Med Biol       Date:  2013-07-24       Impact factor: 3.609

10.  Time-gated Cherenkov emission spectroscopy from linear accelerator irradiation of tissue phantoms.

Authors:  Adam K Glaser; Rongxiao Zhang; Scott C Davis; David J Gladstone; Brian W Pogue
Journal:  Opt Lett       Date:  2012-04-01       Impact factor: 3.776

View more
  1 in total

Review 1.  Recent Advances of Light-Mediated Theranostics.

Authors:  Xiangzhao Ai; Jing Mu; Bengang Xing
Journal:  Theranostics       Date:  2016-10-08       Impact factor: 11.556

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.