Literature DB >> 24938517

Biomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy.

Giuliano Scarcelli1, Sebastien Besner1, Roberto Pineda2, Seok Hyun Yun3.   

Abstract

PURPOSE: Loss of corneal strength is a central feature of keratoconus progression. However, it is currently difficult to measure corneal mechanical changes noninvasively. The objective of this study is to evaluate if Brillouin optical microscopy can differentiate the mechanical properties of keratoconic corneas versus healthy corneas ex vivo.
METHODS: We obtained eight tissue samples from healthy donor corneas used in Descemet's stripping endothelial keratoplasty (DSEK) and 10 advanced keratoconic corneas from patients undergoing deep anterior lamellar keratoplasty (DALK). Within 2 hours after surgery, a confocal Brillouin microscope using a monochromatic laser at 532 nm was used to map the Brillouin frequency shifts of the corneas.
RESULTS: The mean Brillouin shift in the anterior 200 μm of the keratoconic corneas at the cone was measured to be 7.99 ± 0.10 GHz, significantly lower than 8.17 ± 0.06 GHz of the healthy corneas (P < 0.001). The Brillouin shift in the keratoconic corneas decreased with depth from the anterior toward posterior regions with a steeper slope than in the healthy corneas (P < 0.001). Within keratoconic corneas, the Brillouin shift in regions away from the apex of the cone was significantly higher than within the cone region (P < 0.001).
CONCLUSIONS: Brillouin measurements revealed notable differences between healthy and keratoconic corneas. Importantly, Brillouin imaging showed that the mechanical loss is primarily concentrated within the area of the keratoconic cone. Outside the cone, the Brillouin shift was comparable with that of healthy corneas. The results demonstrate the potential of Brillouin microscopy for diagnosis and treatment monitoring of keratoconus. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

Entities:  

Keywords:  Brillouin microscopy; corneal biomechanics; keratoconus

Mesh:

Year:  2014        PMID: 24938517      PMCID: PMC4109405          DOI: 10.1167/iovs.14-14450

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  40 in total

1.  Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

Authors:  David A Luce
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

2.  EMMPRIN and MMP-1 in keratoconus.

Authors:  Hannu P S Seppälä; Marko Määttä; Mikko Rautia; Zygmunt Mackiewicz; Ilpo Tuisku; Timo Tervo; Yrjö T Konttinen
Journal:  Cornea       Date:  2006-04       Impact factor: 2.651

3.  Confocal Brillouin microscopy for three-dimensional mechanical imaging.

Authors:  Giuliano Scarcelli; Seok Hyun Yun
Journal:  Nat Photonics       Date:  2007-12-09       Impact factor: 38.771

4.  Dynamic corneal imaging.

Authors:  Günther Grabner; Reinhard Eilmsteiner; Christian Steindl; Josef Ruckhofer; Renzo Mattioli; Wolfgang Husinsky
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

5.  Ocular response analyzer measurements in keratoconus with normal central corneal thickness compared with matched normal control eyes.

Authors:  Bruno M Fontes; Renato Ambrósio; Guillermo Coca Velarde; Walton Nosé
Journal:  J Refract Surg       Date:  2010-05-03       Impact factor: 3.573

6.  Genome-wide association analyses identify multiple loci associated with central corneal thickness and keratoconus.

Authors:  Yi Lu; Veronique Vitart; Kathryn P Burdon; Chiea Chuen Khor; Yelena Bykhovskaya; Alireza Mirshahi; Alex W Hewitt; Demelza Koehn; Pirro G Hysi; Wishal D Ramdas; Tanja Zeller; Eranga N Vithana; Belinda K Cornes; Wan-Ting Tay; E Shyong Tai; Ching-Yu Cheng; Jianjun Liu; Jia-Nee Foo; Seang Mei Saw; Gudmar Thorleifsson; Kari Stefansson; David P Dimasi; Richard A Mills; Jenny Mountain; Wei Ang; René Hoehn; Virginie J M Verhoeven; Franz Grus; Roger Wolfs; Raphaële Castagne; Karl J Lackner; Henriët Springelkamp; Jian Yang; Fridbert Jonasson; Dexter Y L Leung; Li J Chen; Clement C Y Tham; Igor Rudan; Zoran Vatavuk; Caroline Hayward; Jane Gibson; Angela J Cree; Alex MacLeod; Sarah Ennis; Ozren Polasek; Harry Campbell; James F Wilson; Ananth C Viswanathan; Brian Fleck; Xiaohui Li; David Siscovick; Kent D Taylor; Jerome I Rotter; Seyhan Yazar; Megan Ulmer; Jun Li; Brian L Yaspan; Ayse B Ozel; Julia E Richards; Sayoko E Moroi; Jonathan L Haines; Jae H Kang; Louis R Pasquale; R Rand Allingham; Allison Ashley-Koch; Paul Mitchell; Jie Jin Wang; Alan F Wright; Craig Pennell; Timothy D Spector; Terri L Young; Caroline C W Klaver; Nicholas G Martin; Grant W Montgomery; Michael G Anderson; Tin Aung; Colin E Willoughby; Janey L Wiggs; Chi P Pang; Unnur Thorsteinsdottir; Andrew J Lotery; Christopher J Hammond; Cornelia M van Duijn; Michael A Hauser; Yaron S Rabinowitz; Norbert Pfeiffer; David A Mackey; Jamie E Craig; Stuart Macgregor; Tien Y Wong
Journal:  Nat Genet       Date:  2013-01-06       Impact factor: 38.330

7.  Corneal biomechanical metrics and anterior segment parameters in mild keratoconus.

Authors:  Bruno M Fontes; Renato Ambrósio; Daniela Jardim; Guillermo C Velarde; Walton Nosé
Journal:  Ophthalmology       Date:  2010-04       Impact factor: 12.079

8.  Cross-axis cascading of spectral dispersion.

Authors:  Giuliano Scarcelli; Pilhan Kim; Seok Hyun Yun
Journal:  Opt Lett       Date:  2008-12-15       Impact factor: 3.776

9.  Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes.

Authors:  Sunil Shah; Mohammed Laiquzzaman; Rajan Bhojwani; Sanjay Mantry; Ian Cunliffe
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-07       Impact factor: 4.799

10.  In vivo structural imaging of the cornea by polarization-resolved second harmonic microscopy.

Authors:  Gaël Latour; Ivan Gusachenko; Laura Kowalczuk; Isabelle Lamarre; Marie-Claire Schanne-Klein
Journal:  Biomed Opt Express       Date:  2011-12-01       Impact factor: 3.732

View more
  59 in total

1.  A Large-Scale Computational Analysis of Corneal Structural Response and Ectasia Risk in Myopic Laser Refractive Surgery.

Authors:  William Joseph Dupps; Ibrahim Seven
Journal:  Trans Am Ophthalmol Soc       Date:  2016-08

2.  Single etalon design for two-stage cross-axis VIPA spectroscopy.

Authors:  Antonio Fiore; Giuliano Scarcelli
Journal:  Biomed Opt Express       Date:  2019-02-28       Impact factor: 3.732

3.  Axial mechanical and structural characterization of keratoconus corneas.

Authors:  Eric Mikula; Moritz Winkler; Tibor Juhasz; Donald J Brown; Golroxan Shoa; Stephanie Tran; M Cristina Kenney; James V Jester
Journal:  Exp Eye Res       Date:  2018-05-26       Impact factor: 3.467

4.  Etalon filters for Brillouin microscopy of highly scattering tissues.

Authors:  Peng Shao; Sebastien Besner; Jitao Zhang; Giuliano Scarcelli; Seok-Hyun Yun
Journal:  Opt Express       Date:  2016-09-19       Impact factor: 3.894

Review 5.  Brillouin microscopy: an emerging tool for mechanobiology.

Authors:  Robert Prevedel; Alba Diz-Muñoz; Giancarlo Ruocco; Giuseppe Antonacci
Journal:  Nat Methods       Date:  2019-09-23       Impact factor: 28.547

6.  The influence of corneal geometrical and biomechanical properties on tonometry readings in keratoconic eyes.

Authors:  Mustafa Değer Bilgeç; Eray Atalay; Ömer Sözer; Hüseyin Gürsoy; Muzaffer Bilgin; Nilgün Yıldırım
Journal:  Int Ophthalmol       Date:  2019-12-02       Impact factor: 2.031

7.  Noninvasive Assessment of Corneal Crosslinking With Phase-Decorrelation Optical Coherence Tomography.

Authors:  Brecken J Blackburn; Shi Gu; Matthew R Ford; Vinícius de Stefano; Michael W Jenkins; William J Dupps; Andrew M Rollins
Journal:  Invest Ophthalmol Vis Sci       Date:  2019-01-02       Impact factor: 4.799

8.  In Vivo Noninvasive Measurement of Young's Modulus of Elasticity in Human Eyes: A Feasibility Study.

Authors:  Arthur J Sit; Shuai-Chun Lin; Arash Kazemi; Jay W McLaren; Christopher M Pruet; Xiaoming Zhang
Journal:  J Glaucoma       Date:  2017-11       Impact factor: 2.503

9.  Characterization of cone size and centre in keratoconic corneas.

Authors:  Ashkan Eliasy; Ahmed Abass; Bernardo T Lopes; Riccardo Vinciguerra; Haixia Zhang; Paolo Vinciguerra; Renato Ambrósio; Cynthia J Roberts; Ahmed Elsheikh
Journal:  J R Soc Interface       Date:  2020-08-05       Impact factor: 4.118

10.  Interfibrillar packing of bovine cornea by table-top and synchrotron scanning SAXS microscopy.

Authors:  T Sibillano; L De Caro; F Scattarella; G Scarcelli; D Siliqi; D Altamura; M Liebi; M Ladisa; O Bunk; C Giannini
Journal:  J Appl Crystallogr       Date:  2016-07-14       Impact factor: 3.304

View more