Ocular response analyzer measurements in keratoconus with normal central corneal thickness compared with matched normal control eyes.

Bruno M Fontes1, Renato Ambrósio, Guillermo Coca Velarde, Walton Nosé.   

Abstract

PURPOSE: To compare corneal hysteresis (CH) and corneal resistance factor (CRF) in eyes with keratoconus with a central corneal thickness (CCT) ≥ 520 μm with CH and CRF in matched controls, and to estimate the sensitivity and specificity of these parameters for discriminating between the two groups.
METHODS: This prospective, comparative case series comprised 19 eyes of 19 patients with keratoconus with CCT ≥ 520 μm and 19 eyes of 19 healthy sex-, age-, and CCT-matched patients who underwent a complete clinical eye examination, corneal topography, tomography, and biomechanical evaluation. The receiver operating characteristic (ROC) curve was used to identify cutoff points that maximized the sensitivity and specificity for discriminating between groups.
RESULTS: Central corneal thickness was 543.1 ± 13.9 μm (range: 520 to 568 μm) in the keratoconus group and 545 ± 12.5 μm (range: 527 to 575 μm) in the control group (P=.6017). Corneal hysteresis was 9.22 ± 1.44 mmHg (range: 6.2 to 11.35 mmHg) in the keratoconus group and 10.58 ± 1.91 mmHg (range: 7.34 to 13.53 mmHg) in the control group (P=.0075). Corneal resistance factor was 8.62 ± 1.52 mmHg (range: 5.60 to 11.20 mmHg) in the keratoconus group and 10.30 ± 1.92 mmHg (range: 6.95 to 14.12 mmHg) in the control group (P=.0049). The ROC curve analyses showed a poor overall predictive accuracy of CH (cutoff, 9.90 mmHg; sensitivity, 78.9%; specificity, 63.2%; test accuracy, 71.05%) and CRF (cutoff, 8.90 mmHg; sensitivity, 68.4%; specificity, 78.9%; test accuracy, 73.65%) for detecting keratoconus in the eyes studied.
CONCLUSIONS: Corneal hysteresis and CRF were statistically lower in the keratoconus group compared with the control group. Given the large overlap, both CH and CRF had low sensitivity and specificity for discriminating between groups. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Year:  2010        PMID: 20481414     DOI: 10.3928/1081597X-20100415-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  23 in total

1.  Brillouin optical microscopy for corneal biomechanics.

Authors:  Giuliano Scarcelli; Roberto Pineda; Seok Hyun Yun
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-01-20       Impact factor: 4.799

2.  Brillouin microscopy of collagen crosslinking: noncontact depth-dependent analysis of corneal elastic modulus.

Authors:  Giuliano Scarcelli; Sabine Kling; Elena Quijano; Roberto Pineda; Susana Marcos; Seok Hyun Yun
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-02-19       Impact factor: 4.799

3.  Quantitative Assessment of Biomechanical Properties of the Human Keratoconus Cornea Using Acoustic Radiation Force Optical Coherence Elastography.

Authors:  Yanzhi Zhao; Hongwei Yang; Yingjie Li; Yongbo Wang; Xiao Han; Yirui Zhu; Yubao Zhang; Guofu Huang
Journal:  Transl Vis Sci Technol       Date:  2022-06-01       Impact factor: 3.048

4.  Anterior pituitary, sex hormones, and keratoconus: Beyond traditional targets.

Authors:  Dimitrios Karamichos; Paulina Escandon; Brenda Vasini; Sarah E Nicholas; Lyly Van; Deanna H Dang; Rebecca L Cunningham; Kamran M Riaz
Journal:  Prog Retin Eye Res       Date:  2021-11-02       Impact factor: 19.704

5.  Noninvasive Assessment of Corneal Crosslinking With Phase-Decorrelation Optical Coherence Tomography.

Authors:  Brecken J Blackburn; Shi Gu; Matthew R Ford; Vinícius de Stefano; Michael W Jenkins; William J Dupps; Andrew M Rollins
Journal:  Invest Ophthalmol Vis Sci       Date:  2019-01-02       Impact factor: 4.799

6.  Biomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy.

Authors:  Giuliano Scarcelli; Sebastien Besner; Roberto Pineda; Seok Hyun Yun
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-06-17       Impact factor: 4.799

7.  Discriminant Value of Custom Ocular Response Analyzer Waveform Derivatives in Forme Fruste Keratoconus.

Authors:  Allan Luz; Bernardo Lopes; Katie M Hallahan; Bruno Valbon; Bruno Fontes; Paulo Schor; William J Dupps; Renato Ambrósio
Journal:  Am J Ophthalmol       Date:  2015-12-29       Impact factor: 5.258

8.  Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device.

Authors:  Laszlo Modis; Ziad Hassan; Eszter Szalai; Zsuzsanna Flaskó; Andras Berta; Gabor Nemeth
Journal:  Int J Ophthalmol       Date:  2016-02-18       Impact factor: 1.779

9.  In vivo Brillouin optical microscopy of the human eye.

Authors:  Giuliano Scarcelli; Seok Hyun Yun
Journal:  Opt Express       Date:  2012-04-09       Impact factor: 3.894

10.  Dynamic OCT measurement of corneal deformation by an air puff in normal and cross-linked corneas.

Authors:  Carlos Dorronsoro; Daniel Pascual; Pablo Pérez-Merino; Sabine Kling; Susana Marcos
Journal:  Biomed Opt Express       Date:  2012-02-09       Impact factor: 3.732