| Literature DB >> 24885810 |
Florian J Wegehaupt1, Tobias T Tauböck, Thomas Attin, Georgios N Belibasakis.
Abstract
BACKGROUND: Surface sealants have been successfully used in the prevention of erosive tooth wear. However, when multiple tooth surfaces should be sealed, the light-curing procedure is very time-consuming. Therefore, the aim of this study was to investigate whether reduced light-curing time (while maintaining similar energy density) has an influence on resin-based surface sealant cytotoxicity.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24885810 PMCID: PMC4019812 DOI: 10.1186/1472-6831-14-48
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Composition of the used surface sealants (manufacturer’s information)
| Seal&Protect (DENTSPLY DeTrey, Konstanz, Germany) Lot: 1203000305 | Di- and trimethacrylate resins, PENTA (dipentaerythritol penta acrylate monophosphate), functionalised amorphous silica, photoinitiators, butylated hydroxytoluene, cetylamine hydrofluoride, triclosan, acetone |
| K-0184 (DENTSPLY DeTrey, Konstanz, Germany) Lot: LAN-18-153-1 | Di- and trimethacrylate resins; PENTA (dipentaerythritol penta acrylate monophosphate), functionalised amorphous silica, photoinitiators, butylated hydroxytoluene, cetylamine hydrofluoride, acetone |
Figure 1LDH release from dental pulp cells. Detailed legend: Percentage (mean ± SD) of extracellularly released LDH activity from dental pulp cells for different sealants (S&P = Seal&Protect and experimental sealant K-0184) and different light-curing settings (light-curing duration in s/light-curing intensity in mW/cm2). Comparisons within the same sealant between the different light-curing settings that are not significantly different, are marked with same letters (lower case letters and capital letters for S&P and K-0184, respectively). Comparisons within the same light-curing setting between the different sealants that are not significantly different, are marked with ns.
Figure 2LDH release from gingival fibroblast. Detailed legend: Percentage (mean ± SD) of extracellularly released LDH activity from gingival fibroblast for different sealants (S&P = Seal&Protect and experimental sealant K-0184) and different light-curing settings (light-curing duration in s/light-curing intensity in mW/cm2). Comparisons within the same sealant between the different light-curing settings that are not significantly different, are marked with same letters (lower case letters and capital letters for S&P and K-0184, respectively). Comparisons within the same light-curing setting between the different sealants that are not significantly different, are marked with ns.